Resumo do conteúdo contido na página número 1 
                    
                        ENGLISH ESpAOL
See page 2 Vea la página 21
Installation Guide
ñ
™
90052/90053/90054/90058 Saturn Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS 
1
41718-01  01/28/2008
028_41718_EngS_1.28.08_Arial.indd   1 1/28/08   10:47:06 AM                                                                                                                                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO pERSONS,   OBSERVE THE FOLLOWING:  1. Use this unit only in a manner intended by the manufacturer. American Society for Heating, Refrigeration and Air-Conditioning  If you have questions, contact the manufacturer. Engineers (ASHRAE), and the local code authorities.  2. Before servicing or cleaning the unit, switch power off at ser- 5. When cutting or drilling into wall(s) or ceiling, do not damage  vice panel and lock the service 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        95044-01-000 Check all the parts.   D If damaged, call   95029-01-000 1-888-830-1326   E for replacements. 75191-01-000 F x4 A 03242-07-133 G 95491-01-000 H B * 74508-03-133 x2 I 3/8” Cable Connector 77521-01 J C * 65219 K x2 I Extra Screws 95583-01/02/03/04-000 L NOTE: Strain relief cable  75184-01-133 * M connector must be  installed. Not Included. 94990-01/02/03-000 N Included. Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes  Before Installation NOTE:  Remove all packin
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        4 3 H E Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush  with the side of the housing. 8 7 F G Remove the wiring cover screw. Remove the wiring cover. 4 41718-01  01/28/2008 028_41718_EngS_1.28.08_Arial.indd   4 1/28/08   10:47:11 AM                                                                                                                                                             
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        9 10 E C   B pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and  secure with the washer. Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below  go to step D11, page15  New Construction - attaching to joist A
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        A13 pull wires through the strain relief. A14 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown. A106 A15 E G Connect 4” duct and vent to the outside. Tape joints.  Install the wiring cover plate. Make sure all  If ducting does not fit securely, an adapter may need  wiring connections are inside the box or under  to be purchased. the wiri
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        ON OFF 0000 A17 A18 0000 H Reinstall the motor by inserting the tabs and pushing up into  Connect wiring from the motor to the wiring cover plate. position. Make sure the wires are not pinched  between the motor and the housing. A19 A20 I Secure the motor by tightening the 2 screws. Turn on the power source. A21 A22 Go to step E1 on page 17  to attach grille. Test the motor. If the motor does not run,   check the plug connection. 7 41718-01  01/28/2008 028_41718_EngS_1.28.08_Arial.indd   7 1/28/
                    
                    Resumo do conteúdo contido na página número 8 
                    
                         New Construction – suspended between joists B12 B11 E D 5/8 5/8 1/2 1/2 Slide the mounting rails into brackets. position the correct depth mark at the bottom edge of  the joist based on the thickness of your sheetrock.      B13 B14 1/8” Bit E Mark position of screws by using holes as a template. Drill a hole in the center of each outline. B15 B16 Insert screws, leaving space between the screw  Attach the rails onto the screws. head and the joist. Screws are not provided. 8 41718-01  01/28/2008 
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        B17 B18 Tighten screws. pull wires through the strain relief. Ground B19 Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown. B20 B21 F G Connect 4” duct and vent to the outside. Tape joints.  Install the wiring cover plate. Make sure all wiring  If ducting does not fit securely, an adapter may need  connections are inside the box or under the  to
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        ON OFF B22 B23 H H Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into  position. Make sure the wires are not pinched   between the motor and the housing. B24 B25 I Secure the motor by tightening the 2 screws. Turn on the power source. B26 B27 Go to step E1 on page 17  to attach grille. Test the motor. If the motor does not run,  check the plug connection. 10 41718-01  01/28/2008 028_41718_EngS_1.28.08_Arial.indd   10 1/28/08   1
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        8”  Existing Construction – accessible from above EXISTING FAN NO EXISTING FAN C11 OR Remove an existing fan and check to make sure the Use the motor housing as a template to mark position. opening is large enough to accommodate the new  motor housing (8”x 8.5”).   C12 E D Cut out an opening for the housing. Slide the mounting rails into brackets. C14 C13 5/8 5/8 1/2 1/2 position the correct depth mark at the bottom edge of the  Mark position of screws by using holes as a template. joist based o
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        C15 C16 1/8” Bit Drill a hole in the center of each outline. Insert screws, leaving space between the screw head  and the joist. Screws are not provided. C18 C17 Attach the rails onto the screws. Tighten screws. C19 C20 Connect 4” duct and vent to the outside. Tape joints. pull wires through the strain relief. If ducting does not fit securely, an adapter may  need to be purchased. 12 41718-01  01/28/2008 028_41718_EngS_1.28.08_Arial.indd   12 1/28/08   10:47:33 AM                                
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        C21 Tighten the strain relief screws. C22 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown. C23 C24 F H G Install the wiring cover plate. Make sure all wiring  Connect wiring from the motor  connections are inside the box or under the  to the wiring cover plate. wiring cover plate. 13 41718-01  01/28/2008 028_41718_EngS_1.28.08_Arial.ind
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        ON OFF C26 C25 I H Secure the motor by tightening the 2 screws. Reinstall the motor by inserting the tabs and pushing up   into position. Make sure the wires are not pinched  between the motor and the housing. C27 C28 Turn on the power source. Test the motor. If the motor does not run,  check the plug connection. C29 Go to step E1 on page 17  to attach grille. 14 41718-01  01/28/2008 028_41718_EngS_1.28.08_Arial.indd   14 1/28/08   10:47:38 AM                                                     
                    
                    Resumo do conteúdo contido na página número 15 
                    
                         Existing Construction – accessible only from below EXISTING FAN D11 D12 E Remove an existing fan and check to make sure the  Move the housing into position above the ceiling. opening is large enough to accommodate the new   motor housing (8”x 8.5”). D13 D14 pull wires through strain relief. Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely,   an adapter may need to be purchased. D15 E Screw pre-loaded screws into joist or framing. 15 41718-01  01/28/2008 0
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        D16 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown.   D17 D18 F H G Install the wiring cover plate. Make sure all wiring  Connect wiring from the motor to the wiring cover plate. connections are inside the box or under   the wiring cover plate. D20 D19 I  H  Reinstall the motor by inserting the tabs and pushing up into Secure the motor
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        ON OFF D22 D21 Turn on the power source. Test the motor. If the motor does not run,   check the plug connection. D23 Go to step E1 on page 17  to attach grille.  Attaching the Grille E1 E2 E M L Connect wiring harness. Remove the thumbscrews. 17 41718-01  01/28/2008 028_41718_EngS_1.28.08_Arial.indd   17 1/28/08   10:47:45 AM                                                                                                                                                                             
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        E3 E4 J K Remove the strain relief bracket screw. position the strain relief bracket under the motor as shown. E5 E6 L Insert the strain relief bracket’s dog-leg tab so that  Align posts A, B, C and D (stamped into motor housing)   it hooks over the lip of the motor. Reinstall the  with posts A, B, C and D (stamped into light fixture).   strain relief bracket screw. Slide light fixture over posts. E8 E7 M Attach thumbscrews. Install 2 Max 60 watt A-15 bulbs (Not Included). WARNING: To reduce the
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        E9 E10 N Align glass dome and push up. Screw glass dome into position.  Trouble Shooting problem: Fan does not come on. Solution: 		 •		 Hunter	Fan	Bath	V entilators	are	extremely	quiet.		 T o	confirm	that	the	fan	is	running,	place	your	hand	near	the	vents	to	feel	 the air movement. 			 •	 T urn	power	on,	replace	fuse,	or	reset	breaker . 			 •	Check	all	plug	connections	to	be	sure	they	are	secure. 			 •	Check	the	wiring	to	make	sure	it	matches	the	wiring	diagram. problem: Light does not come on.
                    
                    Resumo do conteúdo contido na página número 20 
                    
                         Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If	any	part	of	your	Hunter	bath	exhaust	fan	(except	for	glass	fixtures	and	light	bulbs)	fails	at	any	time	within	one	year	after	the	date	of	 sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts  and labor performed a