Resumo do conteúdo contido na página número 1 
                    
                        Manuel d’Instructions
Instructions Manual
Manual de instrucciones 
   KSE912XU                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        INDEX WARNINGS AND REQUIREMENTS .....................................................................................................................................3  RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................6  DIMENSIONS and MAIN PARTS...........................................................................................................................................7  INSTALLATION 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        READ AND SAVE THESE INSTRUCTIONS  The Installer must leave these instructions with the homeowner.  The homeowner must keep these instructions for future reference and for local electrical inspec- tors’ use.  READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD  WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units  unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly  on low or medium setting. Alw
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        W A R N I N G  �  Venting system MUST lead the air outside the building.  �  DO NOT expel the air through a ductwork in an attic or other enclosed space.  �  DO NOT use 4" laundry-type wall caps.  �  Flexible-type ductwork is NOT recommended.  �  DO NOT obstruct the flow of combustion and ventilation air.  �  Failure to follow venting requirements may result in a fire.  ELECTRICAL REQUIREMENTS  A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A  timedel
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO  PERSONS, OBSERVE THE FOLLOWING: Installation Work And Electrical Wiring Must Be  Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, In- cluding Fire-Rated Construction.  Sufficient air is needed for proper combustion and exhausting of gases through the flue  (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment  manufacturer’s guideline and safety standards su
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        RECOMMENDATIONS AND SUGGESTIONS  The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your  specific appliance.  INSTALLATION  � The manufacturer will not be held liable for any damages resulting from incor- rect or improper installation.   � Check that the main voltage corresponds to that indicated on the rating plate  fixed to the inside of the hood.   � The electrical supply must be properly 
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        DIMENSIONS and MAIN PARTS Dimensions   	    Components  	  Ref. Q.ty Product Components  1 1 Hood Body, complete with: Controls, Light, Blower,  Filters    2 1 Telescopic Chimney comprising:   2.1 1 Upper Section  2.2 1 Lower Section  8a 1 Right Air Outlet Grill Aria 8b 1 Left Air Outlet Grill Aria    10 1 Damper    14.1 2 Air Outlet Connection Extension    15 1 Air Outlet Connection     Ref. Q.ty Installation Components  7.2.1 2 Upper Chimney Se
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        INSTALLATION Wall drilling and bracket fixing  
   
 
  Wall marking:  � Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the  center of the area in which the hood will be installed.  � Draw a horizontal line at 24” above the hob.  � Place bracket 7.2.1 on the wall as shown about 1/16” from the ceiling or upper limit aligning  the center (notch) with the vertical reference line.  � Mark the wall at the centers of the holes in the
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Mounting the hood body   � Before attaching the hood body, tighten the two screws Vr lo- cated on the hood body mounting points.  � Hook the hood body onto the screws 12a. � Fully tighten support screws 12a.  � Adjust screws Vr to level the hood body.  Note: The Hood body should be secured to wall studs. If neces- sary, install a wood support behind the dry wall, flush mounted  between 2 studs. This will provide the necessary structure and  support for mounting.  Connections  DUCTED VERSION
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        ELECTRICAL CONNECTION  � Remove the cover from the Field Wiring Compartment with a   	 phillips screwdriver.  	 
 � Feed the Power Supply Cable through the electrical knockout.  	  
 Connect the Power Supply Cable to the range- hood cable.  At- tach the Power Supply Cable grounding lead to the green screw  provided. Attach the White lead of the power supply to the  White lead of the rangehood with a twist-on type wire connec- tor. Attach the Black lead of th
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        USE Control board  Key Function Display  A Switches the motor on and off at the latest Indicates the selected speed  selected speed  B Decreases the suction speed. -  C Increases the suction speed. -  D By pressing this key it is possible to start the  HI and the remaining time appear alternately.   intensive speed from any previously selected  The spot down at the right side flashes once a  speed. This speed has been timed at 10 min- second.  utes. After that time the system activates auto- mat
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        CARE Metal grease filters  Filters can be washed in the dishwasher. They need to be washed  when FF-sign appears on the display or in any case every 2  months, or even more frequently in case of particularly intensive  use of the hood.  Alarm reset   � Press the G-key for at least 2 seconds. Cleaning   � Remove the filters one at a time, supporting them with one  hand and turning the safety knobs (pull and turn).  � Wash the filters. Pay attention not to bend them. Make sure  that filters are co
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Charcoal filter (ductless version)  This filter cannot be washed or regenerated. It has to be replaced when the EF appears on the  display or at least once every 4 months.  Activation of the alarm signal   � In the recycling version hoods the filter saturation alarm has to be activated during the in- stallation or later.  � Switch off the hood and the lights.  � Press the E-key for about 5 seconds until the LED on the display start to move.  � Press the B-key within 5 seconds until a confirmatio