Resumo do conteúdo contido na página número 1 
                    
                         
 
WINE-MATE Cooling Unit 
 
Use & Care Manual 
 
 
VINO1500CD, CTED 
VINO2500CD, CTED 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Vinotemp International Corp. 
Vinotemp International Corp. 
 
 
www.winemate.com 
www.winemate.com 
 
 
                                                                                                                                                                                                                                                                                       
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        Important Safety Information    • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY.  • DO NOT USE A GROUND FAULT INTERRUPTER (GFI).  • A DEDICATED 15 AMPCIRCUIT IS HIGHLY RECOMMENDED.                                                                          - 1 -                                                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        TABLE OF CONTENTS      Feature Description…………………………….……………..3    Installation Instruction………………………………………..5    Temperature Control & Humidity Adjustment………….8    Care Guide……………………………………………………11               Troubleshooting……………………………………………..12    Wiring Diagram……………………………………….………15     Customer Support……………………………………………16    Warranty……………………………………………………….17                                                                                                                      - 2 -                
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Feature Description      • VINO1500CD, CTED and VINO2500CD, CTED cooling units are designed  and used to provide a subtle temperature between 50~65 °F for suitable  space at a normal environment.   • The refrigerated space will maintain humidity of 50~70% RH even when  the environment becomes dry and humid.  • These temperatures and humilities are optimized for long term storage of  wine.  • Bottom cold-air supply is optimized for use in the wine cabinets.   • Multiple options for top and rear h
                    
                    Resumo do conteúdo contido na página número 5 
                    
                          Fig. 1.2 DIMENSIONS (in)        The dimension and capacity are specified as follows:    Cooling Bottle  Model Exhaust Electrical Weight  Capacity, CFM Capacity  55°F/ 75°F  55°F/ 75°F  1500 Btu/h,  150  800 115V/60Hz  1500cd 50 lb  Rear Exhaust  120 CFM cu ft bottles 4A  1500 Btu/h,  150  800 115V/60Hz  1500cted Top Exhaust 50 lb  120 CFM cu ft bottles 4A  2500 Btu/h,  250  1200 115V/60Hz  2500cd Rear Exhaust 55 lb  180 CFM cu ft bottles 5A  2500 Btu/h,  250  1200 115V/60Hz  2500cted Top Exhau
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Installation Instruction      1. Cabinet Location    • Place the wine cabinet in a properly ventilated location. Otherwise, heat  exhausted by the cooling unit will build up and it will not operate properly.   • The exhaust area must not be a closed space and must be ventilated. The  ambient temperatures shall not be higher than 90 °F or lower than 50 °F.    1) Rear Exhaust Location  • Leave min 6 “clearance from the rear to the wall.  • Leave min 12” clearance from the top to the ceiling.  • Le
                    
                    Resumo do conteúdo contido na página número 7 
                    
                            Fig. 2.2 MOUNTING CUTOUT & GASKET LIPS  (LOCATED AT THE CABINET)            Fig. 2.3 TOP EXHAUST GASKET  (LOCATED ON THE COOLING UNIT)                                                                      - 6 -                                                                                                                                                                                                                                                                                               
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        • Cut a rectangular inside opening at the rear of the cabinet with the 1/4”  clearance inwards to the width and height of the cooling unit. By not going  through, leave 1/2” lip inside at the wall to place the gaskets (see Fig. 2.2).  • If top exhaust, cut another rectangular opening at the top of the cabinet to  the length and width of the top exhaust (see Fig.2.2).  • Make 2 holes at the ceiling to install the 1/4 inside diameter wood thread  inserts (see Fig.2.2).  • Place the gaskets (1) on 
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Temperature Control & Humidity Adjustment    1. Temperature Setting    • Set the temperature at 55 °F for the optimum aging of wine  • On initial start-up, the time required to reach the desired temperature  will vary, depending on the quantity of bottles, temperature setting  and surrounding temperature.  • Allow 24 hours to stabilize the temperature for each new temperature  setting operation    2. Use of the controller      Fig. 3.1 DIGITAL CONTROLLER    1) Display  During normal operating co
                    
                    Resumo do conteúdo contido na página número 10 
                    
                            2) Alarm Signals  2.1 Code Description        2.2 Alarm Recovery   Probe alarms P1”, start a few seconds after the fault in the related probe; they  automatically stop a few seconds after the probe restarts normal operation.  Check connections before replacing the probe. Temperature alarms “HA”, “LA”  automatically stops as soon as the temperature returns to normal value. Alarm  “CA” (with i1F=PAL) recovers only by switching off and on the instrument.     3) Temperature Set-Point  3.1 How to
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        2. The value of the set point will be displayed and the “°C” or “°F” LED starts  blinking;   3. To change the Set value, push the keys  or  arrows within 10s.   4. To memorize the new set point value, push the SET key again or wait 10s.    4) Humidity Adjustment  The parameter Fon is used to adjust the humidity in the wine cabinet. The higher  value of Fon, the higher relative humidity will be.  1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.  2. Release the keys, t
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Care Guide       I  I. Condenser Coil Cleaning    • The condenser coil is on the ambient air intake side of the cooling unit.  • Clean the condenser coil regularly. Coil may need to be cleaned at least  every 6 months.  • Unplug the cooling unit or disconnect power.  • Use a vacuum cleaner with an extended attachment to clean the coil when it  is dusty or dirty.  • Plug the cooling unit or reconnect power.    II. Moisture Removing    • Remove the extra condensate if it is accumulated in the wine
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Troubleshooting    This Troubleshooting Chart is not prepared to replace the training required for a  professional refrigeration service person, not is it comprehensive    Troubleshooting Chart  Complaint Possible Causes Response  a. Power cord unplugged a. Check for power cord plug  1.Unit not  b. No power to unit b. Check power at receptacle & fuses  running  c. Setting higher than ambient c. Lower temperature setting  temperature   d. Differential too high  d. Decrease the value as to 4 °F  e
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        a. Improper room insulation & seal a. Check for insulation, gasket and  6. “HA” alarm   door opening  blinking and  b. Room too large b. Check for excessive size    beeping,  c. Ambient temperature too high c. Check for installation location  temperature  d. Exhaust restricted  d. Leave minimum 3 feet clearance for  high or not   the exhaust side and leave   minimum 1 foot clearance for the  cooling and   fresh air intake side   running  e. Malfunctioning fans e. Check for both evaporator and  c
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        f. Refrigerant low or leaking f. Check for current and sealed   system leakage  g. Capillary tube blockage g. Check for low side pressure   a. High humidity a. Use drain line   11.Water leak  b. Air leak in wine cellar b. Check for any air leak  c. Evaporator air flow restriction c. Check air flow or air TD crossing   evaporator   d. Water passages restricted d. Clean the drip tray  e. Drip tray leak e. No water overflow but leak  a. Incorrect fuse or breaker a. Check for proper fuse or breaker 
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Wiring Diagram    Fig. 6.1 WIRING DIAGRAM      Fig. 6.2 CALLING FEATURE WIRING DIAGRAM                                                                        - 15 -                                                                                                                                                                                                                                                                                                                                                
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Customer Support      If you still have problems, please contact us at:      Vinotemp International   17631 South Susana Road   Rancho Dominguez, CA 90221   Tel:  (310) 886-3332   Fax: (310) 886-3310   Email: info@vinotemp.com                                                                                                                        - 16 -                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Warranty       Thank you for choosing a Vinotemp cooling unit.    Please enter the complete model and serial numbers in the space provided:    Model_________________________________________________________  Serial No.______________________________________________________    Attach your purchase receipt to this owner’s manual.      1.  Limited Warranty              VINOTEMP warrants its products to be free from defects due to workmanship or  materials under normal use and service, for twelve mont
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        is determined to be faulty and is within the twelve month warranty period  VINOTEMP will, at its discretion, repair or replace the unit and return it free of  charge to the original retail customer. If the unit is found to be in good working  order, or beyond the initial twelve month period, it will be returned freight collect.    2. Limitation of Implied Warranty    VINOTEMP’S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED  TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT.    VINOTEMP SHA