Resumo do conteúdo contido na página número 1 
                    
                         
 
 
 
 
Operation and Installation Manual 
90,100, 150, 225 CFM Cabinet 
Series Dehumidifying Dryers 
Important!  Read Carefully Before Attempting to Install or Operate 
 
B A A
B
B A
A
A0534806
                                    
   
                            Part No:  882.00282.00    Effective: 4/28/08    Bulletin No: DH1-630.1 
 
 
 
Cabinet Series Dehumidifying Dryer Chapter 1: Safety 1                                                                                                      
                    
                    Resumo do conteúdo contido na página número 2 
                    
                                                                                                 Performance figures stated in this manual are based on a standard atmosphere of 59°F (15°C)  at 29.92” Hg (1,014 millibars) at sea level, using 60 hz power. Altitude is an important  consideration when specifying drying and conveying systems. The manufacturer can advise you  on proper selection and sizing of systems for your operating environment.  We are committed to a continuing program of product improvement.  Specificat
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Table of Contents  CHAPTER 1: SAFETY……………………………………………...6  1-1 How to Use This Manual. ............................................................................................6  Safety Symbols Used in this Manual.....................................................................6  1-2 Warnings and Precautions ..........................................................................................7  1-3 Responsibility .......................................................................
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        4-6 Setting the Process Air Temperature ........................................................................22  4-7 PLC Controller...........................................................................................................22  PLC LED Indicators.............................................................................................23  Output LED Indicators .........................................................................................24  Status LED Indicators....
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Charts and Figures      1  Dryer Air Flow Diagram 12 2  Typical Dryer Interface Panel 18 3  Typical Dryer Temperature Controller 20 4  Display Readout for Mode Settings and Available Security Levels  22 5  Typical Subpanel Layout  25 6  Typical Cabinet Dryer Electrical Schematic, Drawings 1 and 2 26-27 7  Required Desiccant Amounts Per Bed 41 Setting List for Process Temperature Controller,  8  Part No. A0548565 43 9  Setting List for Dew Point Controller, Part No. A0548565 46    Cabinet Series 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Chapter 1:  Safety  1-1 How to Use This Manual  Use this manual as a guide and reference for installing, operating, and maintaining the large  dehumidifying dryer.  The purpose is to assist you in applying efficient, proven techniques that  enhance equipment productivity.  This manual covers only light corrective maintenance. No other maintenance should be  undertaken without first contacting a service engineer.  The General Information section outlines models covered, standard features, and saf
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Dryer Safety Tags  Tag Tag  Description Description  Read Operation  High Voltage Inside  & Installation  Enclosure  Manual       Hot! Lifting Point  Protected Earth  Earth Ground  Ground  PE      1-2 Warnings and Precautions  Our equipment is designed to provide safe and reliable operation when installed and operated  within design specifications, following national and local safety codes.  This may include, but is  not limited to OSHA, NEC, CSA, SPI, and any other local, national and internati
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        We have long recognized the importance of safety and have designed and manufactured our  equipment with operator safety as a prime consideration. We expect you, as a user, to abide by  the foregoing recommendations in order to make operator safety a reality.  1-3  Responsibility  These machines are constructed for maximum operator safety when used under standard  operating conditions and when recommended instructions are followed in the maintenance and  operation of the machine.  All personnel e
                    
                    Resumo do conteúdo contido na página número 9 
                    
                         NEVER place your hands or any part of your body in any dangerous location.   NEVER operate, service, or adjust the dryer without appropriate training and first  reading and understanding this manual.   NEVER try to pull material out of the dryer with your hands while it is running!   Before you start the dehumidifying dryer, check the following:  • Remove all tools from the dryer;  • Be sure no objects (tools, nuts, bolts, clamps, bars) are laying in the  area;   If your dryer has been inoperat
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        If you need to repair a large component, use appropriate handling equipment.  Before you use  handling equipment (portable “A” frames, electric boom trucks, fork trucks, overhead cranes) be  sure the load does not exceed the capacity of the handling equipment or cause it to become  unstable.  Carefully test the condition of lifting cables, chains, ropes, slings, and hooks before using them to  lift a load.  Be sure that all non-current carrying parts are correctly connected to earth ground with 
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Chapter 2:  General Information  2-1  Models Covered  This manual provides instructions for installing and operating 90, 100, 150, and 225 CFM  cabinet-style dehumidifying dryers.   2-2 Equipment Function  Our dehumidifying dryers are designed to generate heated, dehumidified air at carefully  controlled temperatures for use in closed-loop plastic drying systems. Moisture removal from  hygroscopic (moisture attracting) plastic pellets is an essential step in the manufacture of high- quality plas
                    
                    Resumo do conteúdo contido na página número 12 
                    
                         Audible/visual critical alarm.   Fusing for blowers and heaters.   Dirty Filter indicator for each individual blower.  2-6    The Closed Loop Drying System  Dehumidifying dryers force hot, dry air through the resin in the drying hopper where the air picks  up moisture from the material and is drawn back to the dryer.  In the dryer, a desiccant bed strips moisture from the air. The dryer then re-heats dried process  air, and sends it back into the drying hopper to dry material again.   This syst
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        2-7 What is Desiccant?  Desiccant is a material which attracts and holds (absorbs) water from the air. Our dehumidifying  dryers use a synthetic crystalline metal aluminosilicate desiccant blended with a clay binder and  formed beads.  Absorbed water is driven from saturated desiccant by heating it to a high temperature (reducing  desiccant capacity to hold water) and forcing air through it. This moisture removal process is  called regeneration.  2-8 The Process/Regeneration Cycle  Our dehumidif
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Chapter 3:   Installation  3-1 Positioning Your Dryer  The dehumidifying dryer system was designed to be wheeled into place. The entire assembly is  mounted on a rugged, compact frame and is equipped with sturdy, 4” (10 cm) heavy-duty casters,  two locking and two swivel.  Caution! Use caution and observe safety rules when placing your dryer!  3-2 Making Electrical Connections   Fulfill all national, state, and local safety and electrical code requirements.   Connections should be made by a qual
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        3-5 Process Air Connections Between the Dryer and Drying Hopper   Remove the cap plugs from the inlet, discharge and bleed tubes before operation.   Use high-temperature flexible dryer hose to connect the dryer to the drying hopper.   Keep the delivery hose as short as possible to minimize heat loss.  Insulated dryer hose is  available for maximum energy savings.   Do not shorten the return hose.   Make sure the hoses are not kinked.   Drying hopper air inlet and outlet locations vary from one d
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Chapter 4:  Controls  4-1 Control Panel Indicator Lights and Switches  Rocker Switches  System ON/OFF Rocker Switch  Used to de-energize control power to the indicator panel, allowing separate control of the dryer  and conveying systems.  Dryer ON/Sequence Shutdown Rocker Switch  Used to start the dryer.  Move this switch to the Sequence Shutdown position to turn off the  process heaters, finish the regeneration cycle and then turn off the dryer.  Optional Alarm Silence Rocker Switch  Press the 
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Indicator Name Description  compressed air, the pressure switch opens and sends  a signal to the PLC controller to shut down dryer  operation.  Dryer operation automatically resumes  when 80 psi (551 kPa/ 5.51 bars) air is restored.  High Temp The High Temp Process Air alarm indicator lights  Process Air Light when the temperature at the process air  thermocouple is above the high alarm set value.  Upon high temperature alarm condition the process  heaters turn off, the process blower remain on.
                    
                    Resumo do conteúdo contido na página número 18 
                    
                          Figure 2-Typical Dyer Interface Panel     Cabinet Series Dehumidifying Dryer  18                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        4-2 Process Air Dew Point Display  The Dew Point display indicates the current process air delivery moisture content. The display  uses a microprocessor-based controller for reading dew point air temperature. The controller is a  modular, self-contained removable unit in the mounting housing. All parameters are factory-set  and adjusted; no field adjustment to the internal controls is necessary. The high dew point alarm  is also factory adjusted.  4-3 Process Air Temperature Controller  Our dehu
                    
                    Resumo do conteúdo contido na página número 20 
                    
                          4-5 Identifying Temperature Controller Buttons   Display Button  This button shifts the display to the next set of parameters. Then, the menu screen displays.   Down Arrow Button  The Down Arrow button lets you lower the process air set point temperature. During setup, it lets  you decrease the value of the parameter displayed on the set point LED readout.   Up Arrow Button  The Up Arrow button lets you raise the process air set point temperature. During setup, it lets you  increase the value