Resumo do conteúdo contido na página número 1 
                    
                        Operation
3A0156A
Electric Airless Sprayers
ENG
- For Portable Airless Spraying of Architectural Coatings and Paints -
3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure
IMPORTANT SAFETY INSTRUCTIONS
Read all warnings and instructions in this 
manual. Save these instructions.
ti15034a
ti14838a
695/795
695/795 Premium Hi
ti15036a
ti15035a Related Manuals:
Repair 3A0157
Parts 3A0158
Gun 311861
MARK V 1095/1595 Premium Hi                                                                           
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        Models:  Models: 695 ULTRA MAX lIl Model QuikReel Hi-Boy Lo-Boy 258719 ✓✓ 258720 ✓ 258722 ✓ 258872 ✓ 258873 ✓ 258874 ✓ 258876 ✓ 258877 ✓✓ 826124 ✓✓ 826125 ✓ 826127 ✓ 795 ULTRA MAX III Model QuikReel Hi-Boy Lo-Boy 258723 ✓✓ 258724 ✓ 258878 ✓✓ 258879 ✓ 258881 ✓ 258882 ✓✓ 826128 ✓✓ 826129 ✓ 1095 ULTRA MAX III Model QuikReel Hi-Boy Lo-Boy 258727 ✓✓ 258728 ✓ 258883 ✓✓ 258884 ✓ 258886 ✓✓ 826130 ✓✓ 826131 ✓ 1595 ULTRA MAX III Model QuikReel Hi-Boy Lo-Boy 258763 ✓✓ 258764 ✓ 258765 ✓✓ 258766 ✓ 826132 ✓✓ 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Warnings Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation  point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back  to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where appli- cable. Grounding Instructions This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Warnings  WARNING FIRE AND EXPLOSION HAZARD  Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire  and explosion: � Do not spray flammable or combustible materials near an open flame or sources of ignition such as cig- arettes, motors, and electrical equipment. � Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity cre- ates a risk of fire or explosion in the presence of paint or solvent f
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. � Always wear appropriate gloves, eye protection, and a respirator or mask when painting. � Do not operate or spray near children. Keep children away from equipment at all times. � Do not overreach or stand on an unstable support. Keep effective footing and balance at all times. � Stay alert and watch what you are doing. � Do not leave the unit energized or under pressure while unattended. When the unit is not in 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Component Identification  Component Identification 13. 12. 1. 2. 11. 3. 4. 5. 9. 6. 7. 8. 10. ti14839a 1 Premium Digital Display 2 ON/OFF Switch ™ 3 WatchDog Switch (not available on Mark V or Standard Units) 4 Pressure Control 5 Prime / Spray Valve 6 Filter 7 Siphon Tube 8Pump ™ 9 Bearing Housing / ProConnect 10 Drain Tube 11 Trigger Lock 12 Model/Serial Tag 13 Hose Reel 6 3A0156A                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Grounding Grounding The sprayer must be grounded. Grounding reduces the  Pails risk of static and electric shock by providing an escape  wire for the electrical current due to static build up or in  the event of a short circuit. The sprayer cord includes a grounding wire with an  appropriate grounding contact. Solvent and oil/based fluids: follow local code. Use  only conductive metal pails, placed on a grounded sur- face such as concrete.  Do not place pail on a nonconductive surface such as  p
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        20 15/20 Amp Switch (Not Available on All Units)  15/20 Amp Switch (Not Available on All Units) ti14919a Select 15A or 20A setting based on your circuit rating. Pressure Relief Procedure 3. Turn pressure to lowest setting. Trigger gun to  relieve pressure. 1. Turn power OFF. Wait 7 seconds for power to  dissipate. ti14841a ti4265a - 4. Put drain tube in pail. Turn prime valve down to  DRAIN position. 2. Lock gun trigger safety. Remove guard and  SwitchTip. ti14842a ti2595a ti10166a ti2769a 8 3A0
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Setup Setup 6. Fill throat packing nut with Graco TSL to prevent  premature packing wear. Do this each time you  spray. 1. Standard Units Only: Connect Graco airless hose  to sprayer. Tighten securely. ti13453a 7. Turn power OFF. ti14843a ti4265a 2. Standard Units Only: Connect other end of hose  to gun and tighten securely. ti4265a 8. Plug power supply cord into a properly grounded  electrical outlet. ti2810a ti13031a 3. Engage gun trigger safety. 9. Turn prime valve down to DRAIN position. ti1
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Startup  Startup 5. Hold gun against grounded metal flushing pail. Trig- ger gun and increase fluid pressure 1/2 turn. Flush  1minute. 1 1. Turn pressure control to lowest pressure. / 2 ti13243a ti4271a 6. Inspect for leaks. Do not stop leaks with hand or a  rag! If leaks occur, perform Pressure Relief Proce- 2. Turn power ON. dure, page 8. Tighten fittings. Perform Startup,  steps 1 - 5. If no leaks, proceed to step 7. ti4266a 7. Place pump in paint pail. ti4266a ti2714a 3. Increase pressure 1/
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Switch Tip Installation Switch Tip Installation Spray 1. Spray test pattern. Increase pressure to eliminate  heavy edges. Use smaller tip size if pressure adjust- ment can not eliminate heavy edges. ™ 1. Use spray tip (A) to insert OneSeal (B) into  guard (C). C A B ti13030a ti13023a 2. Hold gun perpendicular, 10-12 in. (25-30 cm) from  surface. Spray back and forth. Overlap by 50%. Trig- 2. Insert Switch Tip. ger gun after moving and release before stopping. ti13024a ti13025a 3. Screw assembly 
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        ™ WatchDog Protection System (Not Available on All Units)  ™ WatchDog Protection  System (Not Available on All Units) Pump stops automatically when material pail is empty. To Activate: Fast Flush 1. Perform Startup. To flush the hose and gun at an accelerated speed, per- form the following steps: 1. Perform steps 1 - 3 of Cleanup, page 16. 2. Hold gun trigger in and turn prime valve down to  DRAIN position and then over to FAST FLUSH.  ti7398a 2. Premium units with digital display:  Turn WatchDo
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Hose Reel (Not Available on All Units) Hose Reel (Not Available on All Units) 3. Pull reel handle up and turn clockwise to reel in  hose. Be sure to keep your head clear of hose reel while  winding up hose. 1. Make sure hose is routed through hose guide. ti13503a ti13502a NOTE: The hose reel can be locked into two positions:  Usage (A) and Storage (B). (B) (A) ti13504a 2. Lift and turn pivot lock 90° to unlock hose reel. Pull  on hose to remove it from hose reel. ti13563a ti13501a 3A0156A 13    
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Digital Tracking System (Not Available on All Units)  Digital Tracking System (Not Available on All Units) Operation Main Menu Job Gallons Short press to move to next display. Press and hold (5  1. Short press DTS button to move to Job Gallons (or  seconds) to change units or reset data. liters x 10). Psi  ti13612a ti13620a ti13605a ti13610a 1. Turn pressure to lowest setting. Trigger gun to  relieve pressure. Turn prime valve down to DRAIN NOTE: JOB scrolls past, then the number of gallons  pos
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Digital Tracking System (Not Available on All Units) Secondary Menu - Stored Data and  WatchDog Pump Protection Modes 1. Perform Pressure Relief, steps 1 - 4 if they have 7. Short press DTS button. W-DOG scrolls past then  not already been done. OFF displays if watchdog switch is OFF. ON dis- plays if Watchdog switch is ON. 2. Turn power switch on while holding DTS button  down. ti4266a ti13608a ti13626a ti13605a ti13614a 3. SERIAL NUMBER scrolls past and then serial num- ber (e.g. 00001) displa
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Cleanup  Cleanup 5. Turn prime valve down to DRAIN position and allow  flushing fluid to circulate until flushing fluid appears  clear. 1. Perform Pressure Relief Procedure (page 8),  steps 1 - 4. Remove siphon tube set from paint and  place in flushing fluid. Remove tip guard from gun. ti14842a 6. Turn prime valve forward to SPRAY position. Trigger  gun into flushing pail to purge fluid from hose. ti2756a NOTE: Use water for water-base paint, mineral spirits  for oil-base paint, or other solven
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Cleanup 9. Remove filters from gun and sprayer, if installed.  Clean and inspect. Install filters. ti15018a 10. If flushing with water, flush again with mineral spirits,  or Pump Armor, to leave a protective coating to pre- vent freezing or corrosion. ti2895a Pump Armor 11. Wipe sprayer, hose and gun with a rag soaked in  water or mineral spirits. ti2776a 3A0156A 17                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Technical Data  Technical Data Fluid  100 - 120V, 220 - 240V, Generator Motor HP Cycles per Maximum Delivery Maximum Outlet  Model A, Hz A, Hz Minimum W (W) gallon (liter) gpm (lpm) Tip Size npsm 14.8, 9, 5000 2.0 226 0.95 0.031 1/4 in. 695 50/60 50/60 (1490) (60) (3.6) 15, 10, 5000 2.2 195 1.1 0.033 1/4 in. 795 50/60 50/60 (1640) (52) (4.2) 15, N/A 5000 2.2 195 1.1 0.033 3/8 in. Mark IV 50/60 (1640) (52) (4.2) 15, 10, 5000 2.4 123 1.2 0.035 1/4 in. 1095 50/60 50/60 (1790) (33) (4.5) N/A 10, 500
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        Notes Notes 3A0156A 19                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in  material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty  published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by  Graco to be defective. This warranty applies only when the equip