Resumo do conteúdo contido na página número 1 
                    
                        HEAT PUMP PROGRAMMABLE 
THERMOSTAT
SA
PM
3
COOL TEMP
 Model 43168 Owners Manual
Form 44014-01  r010408
1                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        THERMOSTAT CONTROLS Heat Pump  Switches & Buttons ..................................................................................15 Settings ....................................................................................................17 Programmable Thermostat Methods of Operation ..............................................................................19 Icons & Features ......................................................................................33 Model 43168 Important
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Remove Old Thermostat IMPORTANT INFORMATION CAUTION: Do not remove any wiring from the existing thermostat before reading these  1.This thermostat is designed to work on the following systems: instructions carefully. Wires must be labeled prior to removal. •	 Single-Stage Heat Pump IMPORTANT! Turn off the power to the HVAC system at the mainpower panel or at the  •	 Mulit-stage Heat Pump (up to 2 heating and 2 cooling) HVAC system. Remove existing thermostat cover and thermostat. See Figure 1. S
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Wire Labeling •	 After	labeling	the	wires,	disconnect	them	from	the	existing	thermostat	terminals. •	 Remove	 existing	 wallplate.	 T o	 make	 sure	 wires	 do	 not	 fall	 back	 into	 wall	 opening,	 you	 may	 •	 CAUTION! TURN OFF POWER TO THE HEAT PUMP SYSTEM BEFORE YOU ATTEMPT  want to secure them to the wall. TO ACCESS THE THERMOSTAT’S WIRING. •	 If	 the	 hole	 in	 wall	 is	 larger	 than	 necessary	 for	 wires,	 seal	 the	 hole	 with	 insulating	 material	 so	 •	 IMPORTANT! BEFORE DISCONNECTIN
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Connect Wires and Mount Thermostat to Wallplate •	 On	 the	 back	 of	 the	 thermostat	 are	 the	 System	 Set-Up	 Switches.	 See	 Figure	 5.	 (NOTE:	 For	 clarity ,	 the	 illustration of the thermostat circuit board omits most of the circuit board components to clearly show the  •	 Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. See  System Set-Up Switches.) If the heat pump system has an electric auxiliary system, then slide the #1  Figure 4. Ignore
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        •	 Insert	 the	 tabs	 on	 top	 of	 the	 thermostat	 body	 into	 the	 slots	 at	 the	 top	 of	 the	 wallplate.	 Press	 the	 bottom	 of	 THERMOSTAT CONTROLS the thermostat body into the snap on the bottom of the wallplate. (NOTE :	 Do	 not	 force	 the	 thermostat	 onto	 •	 Open the thermostat’s front cover. See Figure 6. the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not  work.) •	 T urn	on	power	to	the	heat	pump	system. •	 If the wiring to the
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        sys Switches and Buttons Switches and Buttons A LCD Readout - displays indoor temperature, set temperature, and information about the heat pump  K system’s operation and status.  B System Switch 	 -	 “em	 heat”	 is	 the	 Emergency	 Heat.	 NOTE:	 The	 Emergency	 Heat	 Mode	 is	 not	 an	 energy	 saving mode, so use it only when necessary. “heat” is the normal heat mode. “off” turns the system off.  “cool” is the normal cooling mode. C Fan Switch - In Auto mode, the fan runs when the system is on f
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Settings The default for this thermostat setting is in a 12 hour format. You can change the format to 24  hour format by pressing Dy a /Tmie and then Program .  The AM/PM indicator will be off when the thermostat is in 24 hour mode.  AM PM Setting	day	and	time: 1. Press Dy a /Tmei .	(AM/PM	and	current	hour	will	flash)   Press UP or Down to adjust the setting.  2. Press Dy a /Teim again to adjust the minute setting.    Press UP or Down to adjust the setting.  3. Press Dy a /Time again to adjust t
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Methods of Operation This thermostat gives you the ability to program up to 4 custom temperature settings per day or  utilize pre-programmed settings.  For manual operation instructions, see pages 21-23. To utilize the pre-programmed settings, see pages 24-25. To create custom programs, see pages 26-29. AM 4 HEAT 18 19                                                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Methods of Operation (cont.) 1. MANUAL OPERATION SA Many people prefer to operate their thermostats manually, adjusting settings as needed. You  UP and Dwon buttons can either temporarily override the settings for the current program, or permanently override all  PM settings and adjust temperatures manually.  2 TEMP If	you	want	to	only	temporarily	override	the	current	program: 1.  Press and hold UP or Dwon for one second to enter Manual Override mode. (Release the  button	when	the	display	flashe
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Methods of Operation (cont.) MANUAL OPERATION, CONT. If	you	want	to	permanently	override	all	settings	and	adjust	the	thermostat	manually: UP and Dwno buttons 1. Press Hol D/r e TUnr until the Hold icon appears.  HOLD 2.  Press and hold UP or Dwno for one second to enter Manual Override mode. (Release the  Hold icon button	when	the	display	flashes.) 3. Press the UP or Dwon buttons to adjust the temperature setting as desired.  4. Press and release Hol D/r e TUrn to return to the normal display.  
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Methods of Operation (cont.) DEFAULT PROGRAMS CHART 2. DEFAULT PROGRAMS This	thermostat	meets	ENERGY 	ST AR	guidelines	for	energy	efficiency .		By	using	the	pre- programmed settings, this thermostat can save you money by optimizing energy usage in  heating and cooling. 10 pm Program 4 o o Heat : 60 F (16 C) o o Refer to the Default Programs Chart on page 24 for detailed information about the pre- Cool : 82 F (28 C) programmed settings. Program 3 o o Heat : 68 F (20 C) o o Cool : 78 F (26 C) 6 am
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Methods of Operation (cont.) AM/PM indicator 3. CREATING CUSTOM PROGRAMS NOTES: UP and Dnwo buttons •	 Program	times	can	be	set	in	10	minute	increments. AM o o •	 Program	temperature	can	be	set	in	increments	of	1 F (1 C). PM •	 After	15	seconds	of	inactivity	during	programming,	the	thermostat	will	return	to	Normal	 Display mode.  sys Tem switch •	 When	setting	each	program	time,	note	the	 AM/PM	indicator .	 •	 Press	Hlo D/r e TUnr at any time to exit Program mode.  Prgorma PROCEDURE: program 1. 
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Methods of Operation (cont.) 3. Press UP or Dnow to change the hour. Press Program to save the hour and adjust the  minute setting.  4. Press UP or Down to change the minute. Press Pogramr to save the minute setting and  adjust the temperature.  UP and Donw M T W TH F SA SU 5. Press UP or Down to change the temperature. Press Porgamr again to move to the next  buttons AM program number. PM  NOTE :	 There	are	4	programs	per	day .	If	you	do	not	wish	to	assign	4	programs	per	day ,	then	 1 2 3 4 HEA
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Icons and Features ® 1. INDIGLO night-light - will backlight the display for easy viewing in the dark. Press any  button to illuminate the light.    2.	 Filter	change	indicator	-	will	flash	after	400	hours	of	system	use	as	a	reminder	to	check	or	 change	your	filter .	Press	and	hold	the	Fil Ter 	button	for	5	seconds	after	changing	the	filter	to	 reset	the	filter	timer .	 2 HEAT TEMP  (Pressing the Filter button for less than 5 seconds will cause the Filter change indicator  icon	to	appear .	 The	
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Icons and Features (cont.) 6. Error mode –  if the thermostat is unable to control your system due to an unexpected  problem,	the	thermostat	will	enter	Error	Mode.	In	this	condition,	the	thermostat	flashes	“E1”,	 “E2”, or “E3” on the LCD display, and shuts off your system. o o 7.  Auto cut off – automatically turns the system off if the temperature rises above 95 F (35  o o C) or drops below 40 F (4 C).   (If your HVAC system has malfunctioned, the system will no longer respond to thermostat  co
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        OPERATION Important Features system em  Review the Set Temperature 1. Temperature Range heat 1. Slide the “system” switch to either the “heat” position or the  “heat” position heat o “cool” position. o o o 99 F  30 F  45 F 95 F  o  o off (37 C) 2. Press either the Up or Down button for less than one second.  (0 C) o o (7 C) (35 C) The LCD Display will show “set temp” and the set temperature. “cool” position cool Out of range Out of range Program range Change the Set Temperature “LO” “HI” 1. Pres
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        Setting Options T o	set	the	Span	setting	of	the	2nd	stage: The	following	Options	are	available	on	your	thermostat: 1. Press	 Program	 after	 you	 finish	 setting	 the	 Stage	 1	 span.	 The	 LCD	 Display	 will	 show	 “ST A 	 2”	 and	 the	 2nd	 1. 1st stage span - The factory setting for Stage 1 heating and cooling is 1, meaning that your thermostat will  stage Span setting, either 1, 2 (factory setting), 3, 4, or 5, meaning that the Span setting is at 2°F (1°C),  cycle at 1°F (0.5°C) above and be
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Filter Reminder TROUBLESHOOTING The	LCD	Display	will	show	“filter”	after	every	400	hours	of	fan	operation,	as	a	reminder	to	change	the	 Problem Solution HV AC	system’ s	filter	as	soon	as	possible. 1. Check the Fan Switch. The fan will run continuously if the Fan switch is in  Fan runs continuously Resetting Your Thermostat program the “on” position. Should you desire the thermostat’s factory settings and default set- day/time tings, use the tip of a paper clip to press the “reset” button. Pressi