Resumo do conteúdo contido na página número 1 
                    
                        P/N: IS3200 
Rev. D 
   
  
 
__________________________________________________________________________________________ 
 
OWNER’S MANUAL 
INSTALLATION, OPERATION, & PARTS 
                                                                   
                *50HZ Models are not UL Listed.                     
™
TriStar Pump Series 
 
The Hayward TriStar Pump is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that is 
equipped with large capacity filt
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        ™ TriStar Pump Series ____________________                      _____________________________Page 2 of 15       IMPORTANT SAFETY INSTRUCTIONS  Before installing or servicing this electrical equipment, turn power supply OFF.    Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in injury.       This is the safety-alert symbol. When you see this symbol on your pump or in this manual, look for one of the following  signal words and
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        ™ TriStar Pump Series __________            _____                ________________________________Page 3 of 15       WARNING – It is required that licensed electricians do all electrical wiring.  Risk of  Electric Shock.  Hazardous voltage can shock, burn, and cause death or serious property damage.  To  reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply.  Provide a  properly located electrical receptacle.  All electrical wiring MUST be in conforman
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        ™ TriStar Pump Series __________            _____                ______________________________ Page 4 of 15       WARNING – Hazardous Pressure.  Pool and spa water circulation systems operate under  hazardous pressure during start-up, normal operation, and after pump shut-off.  Stand clear of circulation  system equipment during pump start-up.  Failure to follow safety and operation instructions could result in  violent separation of the pump housing and cover due to pressure in the system, whi
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        ™ TriStar Pump Series__________            _____                ______________________________ Page 5 of 15    Product Specifications  HP FR “A” MR “A”  ½  13 5/8” -  ¾  13 7/8” 13 3/8”  1 14 3/8” 13 7/8”  1 * 14 3/8” -  1 ½  14 7/8” 13 7/8”  1 ½ * 14 7/8” 14 3/8”  2 14 7/8” 15 1/8”  2 * 14 7/8” 14 7/8”  2 ½  - 14 7/8”  2 ½ * - 14 7/8”  3 17 1/8” 15 5/8”  3 ** 14 1/2” -  *     Two-Speed Pump  ** Three-Phase Pump      Installation Instructions     WARNING – This product should be installed and se
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        ™ TriStar Pump Series __________            _____              _______________________________ Page 6 of 15    Pump Mounting (cont’d.)       WARNING – Hazardous Pressure.  Pumps, filters, and other equipment/ components of a  swimming pool filtration system operate under pressure.  Incorrectly installed and/or improperly tested  filtration equipment and/or components may fail resulting in severe personal injury or death.      Plumbing    Use Teflon tape to seal threaded connections on molded pla
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        ™ TriStar Pump Series __________            _____              _______________________________ Page 7 of 15    Electrical (cont’d.)    Voltage    Voltage at motor MUST NOT be more than 10% above or below motor name plate rated voltage, or motor may  overheat, causing overload tripping and reduced component life.  If voltage is less than 90% or more than 110% of  rated voltage when motor is running at full load, consult power company.    Grounding And Bonding    Install, ground, bond, and wire mo
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        ™ TriStar Pump Series ___________________                      ______________________________Page 8 of 15              WARNING – All suction and discharge valves MUST be OPEN, as well as filter air relief  valve (if available) on filter, when starting the circulating pump system.  Failure to do so could result in  severe personal injury.      Starting/Priming the Pump:    Fill strainer housing with water to suction pipe level.  If water leakage occurs from anywhere on the pump or filter, DO  NOT
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        ™ TriStar Pump Series ___________________                      ______________________________Page 9 of 15           Storage/Winterization      WARNING – Separation Hazard.  Do not purge the system with compressed air.  Purging  the system with compressed air can cause components to explode, with risk of severe injury or death to  anyone nearby.  Use only a low pressure (below 5 PSI), high volume blower when air purging the pump,  filter, or piping.          ATTENTION – Allowing the pump to freez
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        ™ TriStar Pump Series ___________________                   ______________________________ Page 10 of 15             Removing the Impeller  (See Parts Diagram on page 11 of this manual for pump component locations.)    3. Remove the motor canopy by removing the two (2) screws and pulling the canopy away from the motor.    4. To prevent motor shaft from turning, carefully place a 7/16" open-end wrench over the two (2) flats on the end of  the shaft.     5. Rotate the impeller screw (item #10) clo
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        ™ TriStar Pump Series ___________________                      _____________________________Page 11 of 15         Replacement Parts      Parts Diagram    Detail of motor  canopy with screws.      Parts Listing    Ref. No. Part No. Description Ctn. Qty.  1 SPX3200UNKIT Union Connector Kit  (Includes Union Nut, Union Connector, Union Gasket - 2 ea.) 1  2 SPX3200UG Union Gasket 1  3 SPX3200A Pump Strainer Housing, 2” x 2 1/2” with Drain Plugs, threaded style 1  4 SPX3200DLS Strainer Cover Kit  (Inc
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        ™ TriStar Pump Series ___________________                      _________________________        Page 12 of 15     Parts Listing (cont’d.)    Ref. No. Part No. Description Ctn. Qty.  12 SPX3205C Impeller for ½ HP with Impeller Screw 10   SPX3207C Impeller for ¾ HP with Impeller Screw 10   SPX3207CM Impeller for 1 HP with Impeller Screw  (Max Rate) 10   SPX3210C Impeller for 1 HP with Impeller Screw  (Full Rate) 10   SPX3215C Impeller for 1 ½ HP with Impeller Screw 10   SPX3220C Impeller for 2 HP 
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        ™ TriStar Pump Series                                                ____________________Page 13 of 15             Troubleshooting    Motor Will NOT Start – Check For:    Make sure the terminal board connections agree with the wiring diagram on motor data plate label.  Be sure motor is wired  for available field supply voltage (see pump operating label).    1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI’s, or blown fuses.  Solution:  Check all co
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        ™ TriStar Pump Series ___________________                      ____________________________  Page 14 of 15         Low Flow – Generally, Check For: (cont’d.)    2. Undersized pool piping.  Solution:  Correct piping size.  3. Plugged or restricted discharge line of filter, valve partially closed (high gauge reading).  Solution:  Sand filters – backwash as per manufacturer’s instructions; D.E. filters – backwash as per manufacturer’s  instructions; Cartridge filters – clean or replace cartridge.  
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        ™ TriStar Pump Series          Page 15 of 15                             ® HAYWARD LIMITED WARRANTY        This pump was inspected before shipment from our plant.  To original purchasers of this pump, Hayward Pool    Products, Inc., 620 Division Street, Elizabeth, New Jersey, warrants its products free from defects in materials and    workmanship for a period of ONE (1) year from the date of purchase.     Parts which fail or become defective during the warranty period, except as a result of free