Resumo do conteúdo contido na página número 1 
                    
                        ELECTRIC WATER HEATER 
 
A Spanish language version of these instructions is available by contacting 
the manufacturer listed on the rating plate. 
La version espanola de estas instruccions se puede obtener al escribirle a la 
fábrica cuyo nombre aparece in la placa de especificaciones. 
 
INSTALLATION & OPERATING 
INSTRUCTION MANUAL 
 
THE WARRANTY ON THIS WATER HEATER IS IN EFFECT ONLY WHEN 
THE WATER HEATER IS INSTALLED AND OPERATED IN 
ACCORDANCE WITH LOCAL CODES AND THESE INSTRUCTIONS.  
TH
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        TABLE OF CONTENTS  General Information ........................................................ 3  Installation ....................................................................... 4  Locating The Water Heater ......................................... 4  Water Connections...................................................... 6  Electrical Connections................................................13  General Operation ...........................................................14  Thermostat A
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        GENERAL INFORMATION    This electric water heater’s design is certified by Underwriters Laboratories  (UL) and listed in accordance with UL 174. C-UL listed in accordance with  Canadian National Standard C22.2, No. 110-M90.    This water heater must be installed in accordance with local codes.  In the  absence of local codes, install this water heater in accordance with the  N.E.C. Reference Book (latest edition).    The warranty for this water heater is in effect only when the water heater is  
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        General Information continued-    A sacrificial anode is used to extend tank life.  Removal of this anode, for any  reason, will nullify the warranty.  In areas where water is unusually active, an  odor may occur at the hot water faucet due to a reaction between the  sacrificial anode and impurities in the water.  If this should happen, an  alternative anode may be purchased from the supplier that installed this  water heater.  This will minimize the odor while protecting the tank.   Additionall
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Locating The Water Heater continued-    DO NOT locate the water heater where water lines could be subjected  to freezing temperatures.  Locate the water heater so that access  panels and drain valves are accessible. Some models are not equipped  with a drain valve. For those models, install a drain tee in the cold water inlet  as close as practical to the water heater.    Water heater corrosion and component failure can be caused by the heating  and breakdown of airborne chemical vapors.  Exampl
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Water Connections    NOTE:  BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE  MAIN WATER SUPPLY VALVE.    After shutting the main water supply valve, open a faucet to relieve the water  line pressure to prevent any water from leaking out of the pipes while making  the water connections to the water heater.  After the pressure has been  relieved, close the faucet.  The COLD water inlet and HOT water outlet are  identified on top of the water heater.  The fittings at the cold water inlet and  ho
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Water Connections continued-    WARNING  For protection against excessive temperatures and pressure, install  temperature and pressure protective equipment required by local codes,  but not less than a combination temperature and pressure relief valve  certified by a nationally recognized testing laboratory that maintains  periodic inspection of production of listed equipment or materials, as  meeting the Requirements for Relief Valves and Automatic Gas Shutoff  Devices for Hot Water Supply Syst
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Water Connections continued-    WARNING  Hydrogen gas can be produced in a hot water system served by this  water heater that has not been used for a long period of time  (generally two weeks or more).  Hydrogen gas is extremely  flammable.  To reduce the risk of injury under these conditions, it is  recommended that the hot water faucet be opened for several  minutes at the kitchen sink before using any electrical appliance  connected to the hot water system.  If hydrogen is present, there will
                    
                    Resumo do conteúdo contido na página número 9 
                    
                                                                                                                                                                                                                                       Water Connections continued-    This water heater can deliver scalding temperature water at any faucet in the  system.  Be careful whenever using hot water to avoid scalding injury.   Certain appliances, such as dishwashers and automatic clothes washers,  may require increased temperature wat
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Water Connections continued-    Upright Models  (See Figure 1)  The hot and cold water connections are identified on the top of the water  heater.  Connect the hot and cold water lines to the installed nipples using  unions.  Install a listed temperature-pressure relief valve in the opening on  the side of the water heater.        Figure 1  10                                                                                                                                                           
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Water Connections continued-    Utility Models  (See Figure 2)  The hot and cold water connections are identified on the side of the water  heater.  Connect the hot and cold water lines to the installed nipples using  unions.  Install a listed temperature-pressure relief valve in the opening on  the side of the water heater.  Install a vacuum relief anti-siphon device in the  cold water inlet line when using the side cold water connection.    The 6 and 12 gallon models are equipped for installat
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Water Connections continued-    Table Top Models  (See Figure 3) The hot water outlet and cold water  inlet are identified on the back panel of the water heater.  Referring to figure  3, remove the two screws that are holding the service access panel in place.   Remove front panel for access.  Wedge a flat bladed screwdriver into the  front joint between the top and side panels and force the top panel upward.   This will separate the top panel from the water heater and allow further  access to t
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Electrical Connections    Before any electrical connections are made, be sure that the water heater is  full of water and that the manual shut-off valve in the cold water supply line is  open. Check the rating plate and wiring diagram before proceeding.  This  electric water heater was built and wired in accordance with the Underwriters  Laboratories testing approvals requirements.  The temperature limiting  device is of the manual reset, trip-free type and has been factory installed to  interru
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        GENERAL OPERATION  Before closing the switch to allow electric current to flow to the  water heater, make certain that the water heater is full of water and  that the cold water inlet valve is open.  Complete failure of the  heating element(s) will result if they are not totally immersed in  water at all times.  Failure of the element(s) due to dry-firing is not  covered by warranty.    When the switch is closed, the operation of this electric water heater is  automatic.  The thermostats are pre
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Thermostat Adjustment    CAUTION  Before adjusting thermostat(s), turn off power supply to the water heater.    The temperature of the water can be changed by adjusting the thermostat(s).   Before any work is done on the water heater, disconnect all power to the  water heater by opening the switch at the main electrical circuit breaker or  fuse box.  Remove the access panels or front panel on table tops, fold the  insulation outward away from the controls.  Set the thermostat(s) to the  desired 
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        MAINTENANCE    IMPORTANT  The water heater should be inspected at a minimum of annually by a  qualified service technician for damaged components.  DO NOT operate  this water heater if any part is found damaged.    Shut off the electric power whenever the water supply to the water heater is  off. Shut off the electric power and water supply, drain the water heater  completely to prevent freezing whenever the building is left unoccupied  during the cold weather months.  In order to insure efficie
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Maintenance continued-    3. At least once a year, check the combination temperature and pressure  relief valve to insure that the valve has not become encrusted with lime.   Lift the lever at the top of the temperature-pressure relief valve several  times until the valve seats properly without leaking and operates freely.    WARNING  When lifting lever of temperature-pressure relief valve, hot water will be  released under pressure.  Be certain that any released water does not  result in bodily
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Maintenance continued-    Contact your local plumbing supplier or plumbing professional for  replacement parts or contact the company at the address displayed on the  rating plate of the water heater.    For faster and better service, please provide the part name, model, and  serial number(s) of the water heater(s) when ordering parts.    READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH  OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED.  Manufactured under one or more of the following
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        NOTES        19                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        NOTES  20