Resumo do conteúdo contido na página número 1 
                    
                         
 
 
 
 
 
TM
JUNGLE MIST JUNIOR ANTI-DRIP 
Operating Instructions 
 
 
 
 
 
110VAC P/N 100072   
12VDC P/N 100068 
230VAC P/N 100074 (w/transformer)  
 
 
 
 
 
                                                                                                                                                                                                                                                                                                                                                
                    
                    Resumo do conteúdo contido na página número 2 
                    
                                    TM ! Thank you for purchasing this Jungle Mist Junior Anti-Drip    ! As you will notice from the table of contents, the manual for your new  pump is quite extensive.  To guarantee perfect and successful work with  this machine, please take time to read the manual carefully.    ! Do not operate before changing oil cap!    ! And finally, we believe you will enjoy many years of dependable, trouble  free service if you properly install and maintain your Jungle Mist Junior  TM Anti-Drip  
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Contents     1. Equipment Supplied    3  2. Accessories and Parts   3  3. Safety information    4  4. Grounding Instructions   4  5. Receiving and Unpacking   5  5.1 Checking for Damage in Shipping  5.2 Checking Inventory of Parts    6. Hooking up the Pump    6   6.1 Installation of Pump  6.2 Water Supply  6.3 Water Filter Installation  6.4 Anti-Drip Extension    7. Mist Line Layout Strategies   7  7.1 Light, Medium or Heavy Haze  7.2 Indoor Fog Curtains  7.3 Raise Humidity to Keep Dust Down  7.
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        1. Equipment Supplied    ! Jungle Mist Junior Anti-Drip System   (Please see section 5.2 for a complete checklist.)    2. Accessories and Parts    100068  10 Nozzle Anti-Drip Pump Kit 12 VDC  250042  Universal DMX Relay  3-pin XLR, Heavy Duty    600720  Filter Housing with Bracket Kit    600721  5-Micron Sediment Filter Cartridge    600722  1.5" Automatic Drain Valve    600723  .008 Nozzle with 10/24 Thread    600724  .012 Nozzle with 10/24 Thread    600725  Push Connector Quick Device - Tee Onl
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        3. Safety Information    3.3  WARNING: Read through the entire instructions before attempting installation.     • Risk of electrical shock - This pump is supplied with a grounding conductor. To  reduce risk of electrical shock, connect only to a properly grounded, grounding type  receptacle.  • Plug the unit into a dedicated, fused circuit.  • Install pump on a flat, level, solid foundation. This pump is non-submersible.    4.4  CAUTIONS:     • Pump warranty is voided by failure to use factory- 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        5.  Receiving and Unpacking    5.1 CHECKING FOR DAMAGE IN SHIPPING    • Carefully examine contents for signs of damage in shipping.  Immediately notify the  carrier if damage is detected that was not visible upon receipt of shipment.    5.2 CHECKING INVENTORY OF PARTS    TM   Jungle Mist Junior P/N 100072 (12VDC P/N 100068)    CITC   ITEM# QTY PART DESCRIPTION Received   1 Pump Assembly, Chassis & Cover                  (check for correct voltage)  600717 110VAC model  600716 12VDC model    Note
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        6. Hooking up the Pump    6.1 INSTALLATION OF PUMP    • The pump should be set inside a covered area on a level surface such as a stage or  platform. Do not set it on a soft surface as the vibration will sink the unit.    6.2 WATER SUPPLY    • Insure that the water source being used can supply enough water for the demand of  the pump.  Use a minimum ¾” hose (19  mm) with at least 40 PSI (2.8 bar) of clean  water.    6.3 WATER FILTER INSTALLATION    • NOTE!  Use factory-supplied water filter in w
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        6.4 ANTI-DRIP EXTENSION    • With anti-drip, you can stop drips from occurring when stopping and starting the  TM Jungle Mist Junior Anti-Drip .  Each time you stop the system, the auto-drain valve  removes a slight amount of water to reduce pressure (1/4 cup) to drain into the  bucket.  For testing, place a bucket at rear of pump under tube coming out of the  machine in the back marked DRAIN.  For permanent installation run a hose from the  DRAIN outlet to a convenient sewer drain.    • When us
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        8. Mist Line Assembly    8.1 TUBING CONNECTION     • Use the supplied cutters to begin cutting the supplied high-pressure (black) tubing to  the required lengths (see recommended lengths below).  Be sure to measure the  total length required for the mist line before cutting the tubing.  Only cut what is  needed. We suggest a straight line of 20 feet (6m) at first, because you can change  the shape after testing the unit and the heads.      • RECOMMENDED NOZZLE SEPARATION    Mounting Height      
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        recommended operating pressure range of 600-800 PSI (42-55 bar). If you reduce  the number of nozzles, you will increase pressure.  UNDER NO CIRCUMSTANCES  SHOULD THE PRESSURE EXCEED 800 PSI (55 bar), as this can rupture lines and  cause damage to seals and pump.  This can be caused from not using enough  nozzles.  Extensive time would cause overheating.    8.4 Checking for Leaks    • Check for leaks that may have occurred due to the tubing not being inserted beyond  the o-ring seal.  In case of
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        9.  Maintenance procedures    9.1 SYSTEM PRESSURE    • Your pump includes a 2000 PSI (138 bar) high pressure glycerine-filled gauge.   Check the system pressure periodically during operation  The operating pressure  should be between 600-800 PSI (42–55 bar).  DO NOT EXCEED 800 PSI (55 bar)!  Note: an air bubble will be inside the pressure gauge. This is normal.    9.2 EXTERNAL WATER FILTER INSPECTION    • Shut down water supply to pump before inspecting the filter element.  • To insure the long 
                    
                    Resumo do conteúdo contido na página número 12 
                    
                                                    11 . Technical Data    TM Jungle Mist Junior Anti-Drip   110VAC P/N 100072; 230VAC P/N 100074; 12VDC P/N 100068  Case Dimensions 12" x 10" x 13"   (31 cm x 25 cm x 33 cm)  GPM 0.25  Weight  20 lbs (9 kg)  Shipping Container 28” x 14” x 15”  (71 cm x 35.6 cm x 38 cm)   Shipping Weight 36 lbs (16.4 kg)  Motor HP 1/4hp  Electrical Power 110VAC, 60 Hz, 2 amp  (AC single-phase or DC) 230VAC, 50 Hz, 1 amp  12VDC, 14 amp  Maximum Pressure 800 PSI (55 bar)  Maximum Inlet 40 -
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        12.  Limited Warranty Conditions  TM        Jungle Mist Junior Anti-Drip    1. Subject to the following conditions we will repair any defect or fault in the unit  if it is caused by a proven factory fault and has been advised immediately  after appearance and within 30 days of delivery to the end user.  Insignificant  deviations of the regular product quality does not guarantee replacement  rights, nor do faults or defects caused by water, by generally abnormal  environment conditions or Force M
                    
                    Resumo do conteúdo contido na página número 14 
                    
                          If you should send the unit for service, do not forget to  drain water from system.  Obtain your RMA # by calling  CITC. Payment arrangements for repair must be made  before receiving RMA # in case unit is not covered  under Limited Warranty.      Send unit to:     CITC  RMA # XXXXXXX  th   2100 196 Street SW Suite #138    Lynnwood, WA 98036    Tel: (888) 786-CITC or (425) 776-4950     Fax:  (425) 776-5129    Website:  www.citcfx.com    E-mail: info@citcfx.com