Resumo do conteúdo contido na página número 1 
                    
                        Instructions - Parts
™
Dura-Flo Pumps
311826B
Carbon Steel or Stainless Steel Pumps, with Severe-Duty Rod and Cylinder
Dura-Flo 1800 (430 cc) Pump
Dura-Flo 2400 (580 cc) Pump
Important Safety Instructions
Read all warnings and instructions in this manual. 
Save these instructions.
See page 3 for model information, including maximum work-
ing pressure.
TI8900a
TI8885a
II 2 G                                                                                                                            
                    
                    Resumo do conteúdo contido na página número 2 
                    
                          Contents Models  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ™ Preventive Maintenance Schedule  . . . . . . . . . . 14 Dura-Flo Pumps with NXT Air Motors  . . . . . . . 3 Wet-Cups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ® Dura-Flo Pumps with Viscount Hydraulic Motors 5 Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Warnings  . . . . . . . . . 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Models Models ™ Dura-Flo Pumps with NXT Air Motors Check your pump’s identification plate (ID) for the 6-digit part number of your  pump. Use the following matrix to define the construction of your pump, based  on the six digits. For example, Pump Part No. P15MCD represents the  ID ™ pump (P), pressure ratio (15 :1), low noise exhaust motor with DataTrak (M),  carbon steel construction (C), and 3 ptfe/2 leather packing configuration (D). To  order replacement parts, see Parts section starting on
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Models  Pump Part Air Maximum Maximum Air  No. and Lower Motor Working Pressure Input Pressure Series Part No. Lower Model, Packings Part No. Ratio MPa, bar (psi) MPa, bar (psi) P15LCD, A 222796 Dura-Flo 1800 (430 cc) cst, N34LN0 15:1 10.9, 109 (1580) 0.7, 7.0 (100) 3 PTFE/2 leather P15LSB, A 687055 Dura-Flo 1800 (430 cc) sst, N34LN0 15:1 10.9, 109 (1580) 0.7, 7.0 (100) 3 UHMWPE/2 PTFE P15MCD, A 222796 Dura-Flo 1800 (430 cc) cst, N34LT0 15:1 10.9, 109 (1580) 0.7, 7.0 (100) 3 PTFE/2 leather P15MS
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Models ® Dura-Flo Pumps with Viscount Hydraulic Motors Check your pump’s identification plate (ID) for the 6-digit part number of your  pump. To order replacement parts, see Parts section starting on page 18.  ID Maximum  Pump Part Hydraulic Maximum Hydraulic Input  No. and Lower Motor Working Pressure Pressure Series Part No. Lower Model, Packings Part No. MPa, bar (psi) MPa, bar (psi) 222892, B 222796 Dura-Flo 1800 (430 cc) cst, 235345 18.0, 179 (2600) 10, 103 (1500) 3 PTFE/2 leather 222897, B
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Warnings  Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back  to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where  applicable. WARNING FIRE AND EXPLOSION HAZARD  Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To 
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Warnings WARNING MOVING PARTS HAZARD  Moving parts can pinch or amputate fingers and other body parts. � Keep clear of moving parts. � Do not operate equipment with protective guards or covers removed. � Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,  follow the Pressure Relief Procedure in this manual. Disconnect power or air supply. TOXIC FLUID OR FUMES HAZARD  Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or 
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Installation  Installation Object being sprayed: follow local code.  Grounding Solvent pails used when flushing: follow local code.  Use only conductive metal pails, placed on a grounded  surface. Do not place the pail on a nonconductive sur- face, such as paper or cardboard, which interrupts  grounding continuity. The equipment must be grounded. Grounding reduces  To maintain grounding continuity when flushing or  the risk of static and electric shock by providing an  relieving pressure: hold m
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Installation � Fluid pressure gauge (F) monitors hydraulic oil  Air Line Accessories pressure to the motor to avoid overpressurizing the  motor or lower.  � Pressure- and temperature-compensated flow  control valve (G) prevents the motor from running  too fast and possibly damaging itself. For air-powered pumps, install the following accessories  in the order shown in FIG. 1, using adapters as neces- � Pressure reducing valve (H) with a drain line (E)  sary.  runs directly to the hydraulic retur
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Installation  K J U D E H A V Y B F T S L P R N M TI8433a FIG. 1: Typical Installation, Air-Powered Pumps Key: APump N Electrically Conductive Fluid Supply Hose B Wall Bracket P Fluid Whip Hose D Air Line Lubricator R Gun Swivel E Bleed-type Master Air Valve (required) S Airless Spray Gun F Pump Air Regulator T Fluid Suction Kit H Electrically Conductive Air Supply Hose U Main Air Supply Line J Air Line Filter V Air Line Drain Valve K Air Shutoff Valve Y Pump Ground Wire (required, see page 8 fo
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Installation H F V A Y T J S C U E D R X L G P B M K TI8434a N W Z FIG. 2: Typical Installation, Hydraulic-Powered Pumps Key: APump N Electrically Conductive Fluid Supply Hose B Wall Bracket P Fluid Whip Hose C Hydraulic Supply Line R Gun Swivel D Hydraulic Return Line S Airless Spray Gun E Drain Line (from pressure reducing valve) T Fluid Suction Kit F Pressure Gauge U Hydraulic Supply Line Shutoff Valve G Flow Control Valve V Hydraulic Return Line Shutoff Valve H Pressure Reducing Valve W Hydr
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Operation  Operation Pressure Relief Procedure Trigger Lock Always engage the trigger lock when you stop spraying  to prevent the gun from being triggered accidentally by  hand or if dropped or bumped. Trapped air can cause the pump to cycle unexpectedly,  which could result in serious injury from splashing or  Startup moving parts. 1. Connect the suction kit (T) to the pump's fluid inlet,  and place the tube into the fluid supply.  1. Engage trigger lock. 2. Prepare the pump’s power source: 2. 
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Operation 5. Cycle the pump slowly until all air is pushed out and  the pump and hoses are fully primed. Release the  If your pump accelerates quickly, or is running too  gun trigger and lock the trigger safety latch. The  fast, stop it immediately and check the fluid supply.  pump should stall against pressure when the trigger  If the supply container is empty and air has been  is released. pumped into the lines, refill the container and prime  the pump and the lines with fluid, or flush and le
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Maintenance  Maintenance 4. Set pump to lowest possible fluid pressure, and start  Preventive Maintenance  pump. Schedule 5. Hold a metal part of the gun firmly to a grounded  The operating conditions of your particular system  metal pail. Trigger the gun until clean solvent dis- determine how often maintenance is required. Establish  penses. a preventive maintenance schedule by recording when  and what kind of maintenance is needed, and then 6. Remove gun from hose. See gun manual to further  d
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Troubleshooting Troubleshooting 1. Relieve the pressure, page 12.  2. Check all possible causes and problems before dis- assembling the pump. Problem Cause Solution Pump fails to operate. Restricted line or inadequate air/hydrau- Clear; increase air/hydraulic supply.  lic supply; closed or clogged valves. Check that valves are open. Obstructed fluid hose or gun/valve; fluid Open, clear*; use hose with larger ID hose ID is too small. Fluid dried on displacement rod. Clean; always stop pump at bot
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Repair  Repair Required Tools CAUTION � Set of socket wrenches Use at least two people when lifting, moving, or dis- � Set of adjustable wrenches connecting the pump. If disconnecting the lower, be  � 24 in. adjustable wrench sure to securely brace the pump, or have two people  � Torque wrench hold it while another disconnects it. � Thread lubricant � Anti-seize lubricant 222955 ® ™ Before disconnecting the lower (102) from the  �Loctite 2760 or equivalent motor (101), be sure to note the relati
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Repair 5. Screw the nuts (107) onto the tie rods (106) and  Reconnect the Lower torque as noted in FIG. 4. 6. Screw the coupling nut (103) onto the connecting  rod adapter (105) loosely. Hold the connecting rod  adapter flats with a wrench to keep it from turning.  Use an adjustable wrench to tighten the coupling  Always use connecting rod adapter 184595 and tie  nut. Torque as noted in FIG. 4.  rods 184596 on hydraulic-powered pumps. Other con- necting rod adapters and tie rods do not allow suf
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Parts  Parts Dura-Flo Pumps with NXT Air Motors 101 105 106 104 103 108 102 107 TI8363a 18 311826B                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        Parts 101 102 103 104 105 106 107 108 115 116 MOTOR; LOWER; NUT, cou- COLLAR, ADAPTER ROD, tie NUT, hex; WRENCH SHIELD, SCREW;  Pump Part see see pling coupling 5/8-11 warning 8-32 x 2 in.  No. 311238 311825 (51 mm) P12LCD N34LN0 222801 P12LSA N34LN0 222803 P12MCD N34LT0 222801 P12MSA N34LT0 222803 P12DSA N34DN0 222803 P12ESA N34DT0 222803 P12DCD N34DN0 222801 P12ECD N34DT0 222801 P15LCD N34LN0 222796 P15LSB N34LN0 687055 P15MCD N34LT0 222796 P15MSB N34LT0 687055 P15DSB N34DN0 687055 P15ESB N34D
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Parts  Dura-Flo Pumps with Viscount Hydraulic Motors 101 105 106 104 103 108 102 107 TI8365a Ref. Nos. and Descriptions 101 102 103 104 105 106 107 108 Pump Part MOTOR; see LOWER; see NUT, cou- COLLAR, ADAPTER ROD, tie NUT, hex; WRENCH No. 307158 311825 pling coupling 5/8-11 222892 222796 222897 222805 235345 184096 184130 184595 185596 106166 184278 222834 222801 222900 222803 Qty 1 11 21 33 1 20 311826B