Resumo do conteúdo contido na página número 1 
                    
                        OperatiOn and p arts Manual
MOdel Qp205slt/Qpt205slt
HiGH pressure
CentriFuGal puMp
(HOnda GX240K1pMt2/GX240u1pMt2 
GasOline enGine)
Revision #1 (10/11/10)
To find the latest revision of this 
publication, visit our website at: 
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.                                                                                                                                                                                                       
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        prOpOsitiOn 65 warninG page 2 —Qp205SLT/QpT205SLT CeNTRIFUgaL pUMp • opeRa TIoN aNd paRTS MaNU aL — Rev. #1 (10/11/10)                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        nOtes Qp205SLT/QpT205SLT CeNTRIFUgaL pUMp • opeRa TIoN aNd paRTS MaNU aL — Rev. #1 (10/11/10) — page 3                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        t able OF COntents Honda GX240K1pMt2/  Qp205slt/Qpt205slt  GX240u1pMt2 engine High pressure Centrifugal  Air Cleaner (Dual) Assy. ..................................................34-35 pump Camshaft Assy. ................................................. 36-37 Proposition 65 Warning ........................................... 2 Carburetor Assy. ............................................... 38-41 Table Of Contents .................................................... 4 Control Assy. ...........
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        parts OrderinG prOCedures Ordering parts has never been easier! Choose from three easy options: Effective:  st January 1 , 2006 Best deal! order via Internet (dealers only) : If you have an MQ Account, to obtain a Username  Order parts on-line using Multiquip’s SmartEquip website! and Password, E-mail us at: parts@multiquip. com.   View Parts Diagrams To obtain an MQ Account, contact your   Order Parts District Sales Manager for more information.   Print Specifi cation Information Use the int
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        saFetY inFOrMatiOn FOR YOUR SAFETY AND SAFETY OF OTHERS! HAZARD SYMBOLS Safety precautions should be followed at all Potential hazards associated with the operation of this times when operating this equipment.  Failure equipment will be referenced with hazard symbols which to read and understand the safety messages may appear throughout this manual in conjunction with and operating instructions could result in injury safety messages. to yourself and others. This manual has been developed to prov
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        saFetY inFOrMatiOn  NEVER touch the hot exhaust manifold, GENERAL SAFETY muffler or cylinder. Allow these parts to cool  DO NOT operate or service this equipment before servicing engine or pump. Never before reading the entire manual. The operate the engine with heat shields or equipment is to be operated by trained and guards removed. qualified personnel only! The equipment is  ALWAYS allow the engine to cool before adding fuel or for industrial use only. performing service and maintenance func
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        saFetY inFOrMatiOn ■ NEVER run engine without air cleaner. Severe engine LOADING AND UNLOADING damage may occur. ■ Before lifting, make sure that equipment parts (hook and ■ ALWAYS ensure pump is on level ground before use. vibration insulator) are not damaged and screws are not loosened or lost. ■ NEVER pump volatile, explosive, flammable or low flash point fluids. ■ ALWAYS make sure crane or lifting device has been These fluids could ignite or explode. properly secured to the lifting bail (hoo
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        saFetY inFOrMatiOn REFUELING EMERGENCIES ■ ALWAYS  know the location of the nearest fire extinguisher. ■ ALWAYS  know the location of the nearest first aid kit. ■ In emergencies, always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department.  This information will be invaluable in case of emergency. MAINTENANCE SAFETY ■ NEVER lubricate components or attempt service on a running machine. ■ ALWAYS  al
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        speCiFiCatiOns/diMensiOns (puMp) Table 1. Specifications (pump) Model QP205SLT/QPT205SLT Type High Pressure Centrifugal Pump Suction Size 2.00 in. (50 mm.) 1.00 in. (25 mm.) 2 ea.  Discharge Size 1.50 in. (38 mm.) 1 ea. 126 gallons/minute   Maximum Pumping Capacity (480 liters/minute) Max. Lift 25 ft. (7.62 m) Max. Head 312 ft. (95 m) Dimension  25.2 x 18.9 x 23.2 in.  (L x W x H) (64 x 48 x 59 cm.) Dry Net Weight 99 lbs. (45 Kg.) Figure 1. QP205SLT/QPT205SLT Dimensions page 10 —Qp205SLT/QpT205S
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        speCiFiCatiOns (enGine) Table 2. Specifications (engine) Model HONDA GX240K1PMT2/GX240U1PMT2 Air-cooled 4 stroke, Single  Cylinder, OHV,  Type Horizontal Shaft Gasoline   Engine 2.90 in. x 2.30 in.  Bore x Stroke (73 mm x 58 mm) Displacement 14.81 cc Max Output 8.0 H.P./3,600 R.P.M. Approx. 1.59 U.S. Gallons   Fuel Tank Capacity (6 Liters) Fuel Unleaded Automobile Gasoline Lube Oil Capacity 2-1/3 pints Speed Control Method Centrifugal Fly-weight Type Starting Method Recoil Start Dimension 14.0 x
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        General inFOrMatiOn NeveR place the pump on soft soil. The suction hose or  appLICa TIoN pipe connection should always be checked for tightness  The QP205SLT/QPT205SLT centrifugal pump is a high  and leaks. A small suction leak in the hose or fittings could  pressure pump designed to be used for dewatering  prevent the pump from priming. applications. The suction port on the QP205SLT/ Elevation QPT205SLT uses a 2-inch diameter opening. There are  three discharge ports on the pump, 2 are 1-inch i
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        puMp COMpOnents Figure 2 shows a typical application using the QP205SLT/QPT205SLT centrifugal pump. Please note that this pump is  intended for the removal of clean water. Figure 2. QP205SLT/QPT205SLT Pump Application 6. Pump — The model QP205SLT/QPT205SLT is a  1. discharge port 1.5-Inch — Connect a flexible rubber  2-inch high pressure centrifugal pump and should  hose to this 1.5-inch discharge port on the pump. Make  only be used in clear water applications (agricultural,  sure that the hose
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        basiC enGine Figure 3. Engine Controls and Components INITIaL SeR vICINg 5. Fuel valve Lever — opeN to let fuel flow. CLoSe to  stop the flow of fuel. The engine (See Figure 3) must be checked for proper  lubrication and filled with fuel prior to operation. Refer to the 6. Air Cleaner — Prevents dirt and other debris from  entering the fuel system. Remove wing-nut on top of  manufacturer's engine manual for instructions and details  of operation and servicing. The engine shown above is a air fil
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        inspeCtiOn  3. Insert and remove the dipstick without screwing it into    CaUTIoN the filler neck. Check the oil level shown on the dipstick. ALWAYS wear approved eye and hearing  4. If the oil level is low (See Figure 5), fill to the edge  protection before operating the pump. of the oil filler hole with the recommended oil type   (Table 5). Maximum oil capacity is 1.16 quarts   (1.1 liters).   CaUTIoN Neve R operate the pump in a confined  area or enclosed area structure that does  not provide
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        set -up BeFoRe ST aRTINg  NOTICE 1. Read safety instructions at the  Suction and discharge hoses are available from  beginning of manual. Multiquip. Contact your nearest dealer for more  information. 2. Place pump as near to water as  possible, on a firm flat, level surface. 5. The discharge hose is usually a collapsible  (thin-walled) hose, however if a thin-walled discharge  3. To prime pump, remove fill cap (See Figure 2) and fill  hose is not available, a rigid suction hose can be  pump casi
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        OperatiOn 3. Place the choke lever (See Figure 8) in the “CLOSED”    CaUTIoN position if starting a cold engine. do No T attempt to operate the pump  until the Safety, General Information and  Inspection sections of this manual have  been read and thoroughly understood.  This section is intended to assist the operator with the  initial start-up of the pump. It is extremely important that  this section be read carefully before attempting to use the  pump in the field. STaRTINg THe eNgINe (HoNda) 
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        OperatiOn 6. Grasp the starter grip (See Figure 11) and slowly pull    CaUTIoN it out. The resistance becomes the hardest at a certain  ALWAYS run engine at full speed while pumping. position, corresponding to the compression point. Pull  the starter grip briskly and smoothly for starting. SToppINg THe eNgINe Normal Shutdown 1. Move the throttle lever to the IDLE position (See Figure  14) and run the engine for three minutes at low speed. Figure 11. Starter Grip 7. If the engine has started, slo
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        MaintenanCe (puMp) pUMp vaCUUM TeST adjUSTINg IMpeLLeR CLeaRaNCe 1. If it is necessary to replace impeller or volute, be sure    CAUTION clearance between impeller and volute is adjusted  do No T attempt to start the engine unless the pump  correctly.  has previously been primed with water. Severe pump  2. The impeller should be as close to the volute as  damage will occur if pump has not been primed. possible without rubbing against it. Clearance is  To perform the pump vacuum test do the follo
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        MaintenanCe (puMp) Figure 17. Pump Vacuum Tester page 20 —Qp205SLT/QpT205SLT CeNTRIFUgaL pUMp • opeRa TIoN aNd paRTS MaNU aL — Rev. #1 (10/11/10)