                        INSTALLATION AND 
OPERATION INSTRUCTIONS
VILLA VISTA™
TM
Wood Burning Fireplaces
P/N  850,028M  REV. J  11/2008
MODEL
	 Villa	Vista	
	
This installation manual will enable you to obtain a safe, efficient and 
dependable installation of your fireplace system. Please read and 
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including 
but not l
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        IMPORTANT! GENERAL SAFETY         WARNING        WARNING  PRECAUTIONS. READ AND  Use care when selecting window Never leave children unattended  UNDERSTAND THESE SAFETY  treatments for windows located when there is a fire burning in  RULES BEFORE YOUR FIRST FIRE. near the fireplace.  Avoid using the fireplace. combustible flowing window  WARNING treatments such as curtains                WARNING  on nearby windows that are of  The Villa Vista™ fireplace must  To avoid the risk of damaging  suffi
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        THE FIREPLACE CONGRATULATIONS! INTRODUCTION In selecting this Lennox Hearth Products wood-burning appliance you have chosen one  of the finest fireplaces available.  The Villa Vista™ wood fireplace is a clean burning EPA  The Villa Vista fireplace is an energy efficient,  certified fireplace that is designed to provide you dependable service as well as warmth  heat circulating, close combustion fireplace  and enjoyment for many years to come. using the catalytic technology.  You will receive  a 
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        The first 5 or 6 fires should be small fires of When the catalyst light-off conditions are  OPERATING THE FIREPLACE short duration (about 30 to 60 minutes).  This achieved, the combustor will keep on going  will help cure the refractory bricks.  Ashes that until it runs out of smoke.  Note that the catalyst  Fuel will accumulate in the ashtray will protect it from does not need to be glowing to be working, it  intense heat. The first fires may produce slight can work very well at temperatures we
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Step 2.  Open the air control fully and pull the  Accelerated Combustion Slow Combustion by-pass damper control towards you to put it  When the air combustion damper is almost  The maximum heat output for the Villa Vista™  in the OPEN position.  Light the newspaper.   fireplace is achieved by burning with the com- closed, the fireplace is in a slow combustion  Leave the door open until the fire is well es- phase (see	 Figure	 4). Slow combustion will  bustion air damper opened (see	 Figure	 2). 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Step 3. Keep the combustion air damper and Then, hold it in the upper part of the firebox 3. Do not expect chemical cleaners to keep  the by-pass damper opened for 10 minutes to warm up the chimney.  Wait until the draft your chimney clean.  The rain cap can be  before closing it. It will ensure sufficient tem- is sufficient, then start the fire. removed for inspection and/or cleaning of  peratures for combustor light-off. the chimney.  Using gloves, firmly grip the  lower portion of the rain ca
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Cleaning Procedure (see Figure	6) : 1. Rotate the retainers to release the com- bustor  support plate while holding it to  make sure it  does not drop.  2. Rotate the support plate and remove the  combustor.  ROTATE 3. Remove fly ashes on the combustor  using a soft brush.  4.     Put the combustor back in place. ROTATE Door Frame Care Use a glass cleaner and a soft cloth to polish  the frame.  Do not use abrasives such as steel  wool or steel pads for they may scratch the  ROTATE door frame fin
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        DO NOT USE CHEMICAL GLASS CLEANERS  Door Adjustment ON PAINTED SURFACES AS IT MAY CAUSE  The door may need to be adjusted to be com- THE PAINT TO PEEL. pletely airtight. The gasket airtightness can be  adjusted using the adjustment screw located  CAUTION : DO NOT ALLOW WINDOW CLEANER  on the fireplace facade at the bottom of the TO GET IN CONTACT WITH DOOR GASKET OR  PAINT ON FACADE OR DOOR.  ONCE CLOSED,  fireplace opening.  (An Allen key  # 1/8 will be  CONTACT OF GLASS CLEANER WITH THE  neces
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Framing, Facing and Mantel WARNING: THE HEARTH ExTEN- The construction of the framing, facing, and Fireplace SION IS TO BE INSTALLED ONLY  mantel must be in accordance with the standards  AS ILLUSTRATED. and the following illustrations:  The crack between the fireplace  (see	 Figures	10B.11, 	 	13,	14	and	15 ): and the hearth extension must be Safety Metal Strip 1. Frame the fireplace using 2 x 3 or heavier  sealed with a non-combustible  lumber. Hearth Extension material such as sand-cement  2.
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Corner Installation 21-1/4" D J 2" X 3" MIN. F 19-17/32" E 7’ Min" Plywood 1/2” Back Wall of Chase/Enclosure OUTSIDE CHASE Including Finising Materials if any C L * G B G H Rough Framing Face A (dimension includes finish  ROUGH FRAMING FACE (UNFINISHED SHOWN) material inside framing, if any) Rough Framing Face (Unfinished Shown) * Zero Clearance From Back Spacer to Wall  30-1/16" 11-1/4" Combustion Air Kit 1" 9-3/8" 13-3/8" 22-11/32" 23-1/2" 1-1/2" K Notes FRAMING DIMENSIONS Fireplace Opening Wi
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        INSULATED CHASE CONSTRUCTION Chase Enclosure A chase is a vertical box-like structure construct- ed to surround the fireplace and chimney. Refer  STORM COLLAR to Figure	 12  for a typical chase configuration.  As with all chimney installations, avoid overhead  UNIVERSAL SUPPORT FLASHING WITH STRAP obstructions such as trees, power lines, etc.  ATTACHED TO JOIST A chase should be constructed and insulated  just like any outside wall. In a cold climate, we  recommend the base of the chase should a
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Facing 1.   Combustible wall (such as drywall panels) must be installed flush with the fireplace.  It may not project in front of and on the fireplace (i.e. the  steel facade of the fireplace (see	 Figure	13 ). 2. Decorative frame made of combustible material cannot project in front of and on the fireplace steel front, in the space delimited by the width of  the unit (38") and a height of 54" from the base of the appliance (see	 Figure	15 ). 3. Non-combustible materials such as brick, stone or c
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        HOT AIR DUCTING INSTALLATION Gravity Kit FRAME Double	hot	airoutlet 	 includes:	 	 (see	 Figure	16 ) GRILL  - 2 telescopic lengths  8" I.D.  - 2  90º elbows  8" I.D.  - 2 hot air outlet kits (louvers and     frames)   - 2 adaptors   See components list Page	22 . WARNING:  Both pipes of  the double hot air outlet  The gravity kit allows you to block the upper  must be installed. Any oth- grill of the fireplace with a clean face panel.  To  er installation may cause  do so, follow the steps below:
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        The duct system must be installed respecting  the following: COLLAR RAIN CAP 1.  Remove the top and bottom plates closing up  the 8" diameter holes on top of the fireplace.   Then, cut the insulation in order to obtain two  FLASHING 8" diameter openings.  Fix the adaptors on  the fireplace openings by turning clockwise  (refer	to	 Figures	16	and	17 ). ROOF-SUPPORT ATTIC RADIATION SHIELD 2. Maintain at least a 2" (50mm) clearance  FIRESTOP between the ducts and any combustible  material; the requ
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        OUTSIDE AIR KIT OUTSIDE AIR CONNECTION During operation, the fireplace requires fresh  air for combustion and draws air from outside  the house.  It may starve other fuel burning  ALUMINIUM TAPE OUTSIDE appliances such as gas or oil furnaces.  As  INTAKE well, exhaust fans may compete for air, caus- PLASTIC COVER ing negative pressure in the house, resulting in  smoke entering the house from the fireplace.  This situation is aggravated in modern airtight  SCREW houses. To overcome this potential
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        CHIMNEY SYSTEM CHIMNEY INSTALLATION NOTES 1. If possible, install an interior chimney as it 2' min. will provide better performance.  In areas  with continuous temperatures below 0° F  3' min. 10' (18° C), the use of an exterior chimney in- creases the likelihood of operating problems  such as low draft, high rate of creosoting,  and poor start-up characteristics.  Exterior  chimneys are also prone to down-drafting  and flow reversal.  Installations, which are  located on lower floors in the hou
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        ACBI CHIMNEY INSTALLATION RAIN CAP COLLAR FLASHING UNIVERSAL Figure23 	 SUPPORT ATTIC RADIATION  SHIELD 2.  From below, install a firestop in each ceil- ing/floor separation through which the chimney  will pass.  At the attic level, install an attic  radiation shield from above, (see	 Figure	 24).   S2100+ and ASHT+: Place the first chimney  length on the fireplace, to lock turn 1/4 of a  turn clockwise.  ACBI: A starter section must  be installed before installing the first chimney  FIRESTOP le
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        2.  Install the necessary chimney lengths to  OFFSET CHIMNEY INSTALLATION COLLAR CHIMNEY achieve the required offset.  Lock the chimney  For the minimum chimney height when using  length together.  It is recommended to use three  elbows, see Table	3 and refer to Figure27 	 . (3) metal screws.  If penetrating a wall, use a  wall radiation shield. Note:	 	 Use	of	ACBI	chimney	with	these	fireplaces	 require	 the	 use	 of	 a	 starter	 section	 used	 at	 the	 3.  Use another elbow to turn the chimney
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        DEVIATION TWO LENGTHS BETWEEN ELBOWS ONE LENGTH BETWEEN ELBOWS CHIMNEY ELBOW & 7” LENGHT 12" 18" 36" 48" 12" & 48" 18" & 48" 36" & 48" 48" & 48" 11 1/2" 23 5/8" 5 1/2" 7" 14 3/4" 17 1/2" 19" 26 3/4" DEVIATION (292 mm) (600 mm) (140 mm) (178 mm) (375 mm) (445 mm) (483 mm) (679 mm) 15 TOTAL LENGTH 32 1/4" 38" 55 1/2" 67" 77 1/8" 82 7/8" 100 1/4" 111 1/8" LENGTH (819 mm) (965 mm) (1410 mm) (1702 mm) (1959 mm) (2105 mm) (2218 mm) (2823 mm) ACBI 10 1/2" 13 1/2" 22 1/2" 28 1/2" 33 3/4" 36 3/4" 45 3/4"
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Table	 6  gives maximum height of supported CHIMNEY CHASE AND MULTIPLE TERMINA- CHIMNEY SUPPORT INSTALLATION chimney. TIONS Universal Roof Support For the purpose of this manual, a chimney chase  NOTE: 	 For	 the	 ACBI	 chimney,	 a	 universal	 sec- This support has two possible uses: is considered a part of the chimney system  tion	 must	 be	 used	 every	 20	 feet	 (6	 m)	 instead	 rather than part of a building.  The termination  ofthe 	 	universalroof 	 	support	(ST). must be placed a minimum