Resumo do conteúdo contido na página número 1 
                    
                        www.regency-fi re.com
Owners & 
G36D Zero Clearance Direct Vent Gas Fireplace
Installation Manual
MODELS:    G36D-NG1 Natural Gas     G36D-LP1 Propane
WARNING:   If the information in these instructions are not followed exactly, 
FOR YOUR SAFETY
a fi re or explosion may result causing property damage, personal injury 
What to do if you smell gas:
or loss of life.
FOR YOUR SAFETY:   Do not store or use gasoline or other fl ammable 
         Do not try to light any appliance.
vapors and liquids in th
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        To the New Owner: Congratulations!  You are the owner of a state-of-the-art Gas Fireplace by  FIREPLACE PRODUCTS  INTERNATIONAL.  The G36D is a hand crafted appliance and has been designed  to provide you with all  the warmth and charm of a wood fi replace at the fl ick of a  switch.  The model G36D has been approved by Warnock Hersey for both safety and  effi ciency.  As it also bears our own mark, it promises to provide you with economy,  comfort and security for many trouble free years to follow
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Safety Label ..................................................................4 Operating  ....................................................................34 Instructions ..................................................................34 Lighting Procedure ......................................................34 INSTALLATION Shutdown Procedure ...................................................34 First Fire ............................
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        SAFETY LABEL This is a copy of the label that accompanies  each G36D Zero Clearance Direct Vent Gas  Fireplace. We have printed a copy of the  contents here for your review. The safety label  is located on the front inside base of the unit,  visible when the bottom louver is open. ® NOTE: UltraGlow units are constantly being  improved. Check the label on the unit and if  there is a difference, the label on the unit is  the correct one. W all For the State of Massachusetts, installation  and repa
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        INSTALLATION 14) Under no circumstances should any solid  IMPORTANT MESSAGE   CLOTHING OR OTHER FLAMMABLE  fuels (wood, paper, cardboard, coal, etc.)  MATERIAL SHOULD NOT BE PLACED  be used in this appliance. SAVE THESE  ON OR NEAR THE APPLIANCE.    INSTRUCTIONS 15) The appliance area must be kept clear and  free of combustible materials, (gases and  other fl ammable vapours and liquids). The G36D-NG1 or G36D-LP1 Direct Vent  GENERAL SAFETY  Fireplace must be installed in accordance  Emissions fr
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        INSTALLATION This includes: 5) This appliance is Listed for bedroom   MANUFACTURED  installations when used with a Listed Millivolt  1) Clocking the appliance to ensure the correct Thermostat. Some areas may have further  MOBILE HOME  fi ring rate (rate noted on label 26,000 Btu/h) requirements, check local codes before  after burning appliance for 15 minutes. ADDITIONAL  installation. REQUIREMENTS 2) If required, adjusting the primary air to ensure  6) The G36D Direct Vent Gas Fireplace is  that
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        INSTALLATION 2) Frame in the enclosure for the unit with  CLEARANCES MANTEL LEG  framing material. The framed opening is   37-1/4" high x 36-1/4" wide x 17-3/8" deep  CLEARANCES The clearances listed below are Minimum  (946mm high x 921mm wide x 441mm  distances unless otherwise stated: deep). Combustible mantel leg clearances as per  diagram below: A major cause of chimney related fi res is  failure to maintain required clearances (air  space) to combustible materials. It is of the  greatest imp
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        INSTALLATION COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered   with a non-combustible board. These drawings are to scale at 1:6 (one inch = 6 inches) Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the pai
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        INSTALLATION 3) Attach the standoff securely to the top  T o p Header with 2 screws per standoff (on opposite  10" dia. hol e corners). through wall 1/2" for Fle x Drywal l or for DuraV ent "C" Screw Position: For a facing material depth of 1-1/4"  2" (32mm), the top facing support must be  reversed. 3-1/2" 4" 17-1/8" Opening for gas connectio n Note: 40-1/2" (1029mm) is the minimum  height for both fl ex termination or  Simpson Dura-Vent venting. Top Facing Support and  Side Nailing Strips 5) Th
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS ® ® ® 10 UltraGlow G36D Zero Clearance Direct V G36D Zero Clearance Direct Vent Gas Fireplace ent Gas Fireplace V V . V ertical Inside corner det ail T ermination V ertical T ermination G V A 24" 24" 18" D V E H B B C M Fixed B V V Closed Openable Fixed Closed V Openabl e V F N B L V A B K V A B j A Air supply outlet Area where terminal is not permited V ent terminal A V A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) H
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        INSTALLATION VENTING ® ® ® ® UltraGlow UltraGlow UltraGlow Direct  V Direct  Vent System (Flex) ent System (Flex) Horizontal Terminations Only These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by  Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent  Termination Locations" section. ® ® ® ® UltraGlow UltraGlow UltraGlo
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. ® Description     Simpson Dura-Vent     Selkirk            Amerivent               Security ® TM ®            Direct VentGS Direct-Temp          Direct Vent          Secure Vent 6" Pipe Length, Galvanized   908             4DT-6  N/A  SV4L6 6" Pipe Length, Black    908B             4DT-6B  N/A SV4LB6 7" Pipe Length, Galvanized   N/A             N/A   4D7 #N/A 7" Pipe Length, Black   
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic horizontal termination Flat Wall Installation are: Wall Thickness Vent Length Required  (inches) (inches)  1 Horizontal Termination Cap o 4" -  5-1/2" 6"  1 90 Elbow   1 Rigid Pipe Adaptor 7" -  8-1/2" 9"  1 Wall Thimble 10" - 1-1/2" 12"  1 Length of pipe to suit wall thickness (see chart)  9" - 14-1/2" 11" - 14-5/8" Adj. Pipe Wall thickness  is measured from the back standoffs
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        INSTALLATION  RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ® ® ® ® UltraGlow UltraGlow UltraGlow DIRECT  VENT SYSTEM (FLEX) DIRECT  VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram shows all allowable combinations of vertical runs with horizontal terminations, using using one one 90 90 elbow (two  45 elbows equal one 90 elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid vent systems. All Rigid Pipe Systems All Rigid Pipe Systems 4" inner
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ® ® ® ® UltraGlow UltraGlow UltraGlow DIRECT VENT SYSTEM (FLEX) DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two  45 elbows equal one 90 elbow). o Note: 1) A maximum of two 90 elbows are permitted.  o  2) A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90 elbows are used.  3) Minimum distance between
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS   (Propane & Natural Gas) The G36D is approved for a maximum 23 ft. (7.0m)  vertical,  with a maximum 12 ft. (3.7m) horizontal offset  o o o using two 90 elbows (two  45 elbows equal one 90 elbow) with Rigid Pipe vent systems for Propane and  Natural Gas, as per diagram 1. The G36D is approved for a  maximum 37 ft. (11.3m) straight vertical, including a maximum 20" (0.5m) horizontal  o o o offset using two 90 elbow (two  45 elb
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        INSTALLATION The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, with Rigid  Pipe vent systems for Propane and Natural Gas, as per the diagram 3. The shaded area in the diagram 3 shows all allowable combinations of straight  vertical and offset to vertical terminations with Rigid Pipe vent systems for  o Propane and Natural Gas. Maximum two 45 elbows allowed. •  Vent must be supported at offsets •  Firestops are required at each fl oor level and whenever passing  through a wall. 
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE  Masonry chimneys may take various contours which the fl exible liner will accommodate. However,  CONNECTED TO A CHIMNEY FLUE  keep the fl exible liner as straight as possible, avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. The Air Intake pipe must be attached to the inlet air collar of the termination cap. This appliance is designed to be attached to  two 3" (76mm) co-linear alumini
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS  with Co-linear Flex System for both Residential & Manufactured Homes  into Masonry Fireplaces The shaded area in the diagrams  show the  allowable  vertical terminations. ® UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 19                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        INSTALLATION UNIT INSTALLATION   b) Horizontal runs of vent must be  supported every three feet. Wall straps  WITH HORIZONTAL  are available for this  purpose. TERMINATION 5) Mark the wall for a 10" x 10"  square hole.  Install the vent system according to the The center of the square hole should line  up with the centerline of the horizontal pipe.  manufacturer's instructions included with  the components. Cut and frame the 10 inch square hole in  the exterior wall where the vent will be  termi