Resumo do conteúdo contido na página número 1 
                    
                        Do Not 
Discard
Owner's Manual
Installation and Operation
Model:
Super-Magnum
Coal Stoker Stove
NOTICE
DO NOT DISCARD THIS MANUAL
 •  Important operating and
 •  Read, understand and  •  Leave this manual with 
    maintenance instructions    
     follow these instructions      party responsible for use 
    included.
     for safe installation and      and operation.
     operation.
WARNING WARNING
Please read this entire manual 
HOT SURFACES!
before installation and use of this 
Glass and oth
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        Super-Magnum Coal Stoker Stove Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance,  you have become part of a long standing family committed to meeting the heating needs of consumers with the  most distinctive, powerful and responsible home heating products available.  The Super-Magnum has huge features in an elegant package, giving you 5000 to 100,000+ BTU when you need  it, automatically. You need only set your desired room temperature, keep 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Super-Magnum Coal Stoker Stove TABLE OF CONTENTS Section 1: Listing and Code Approvals Section 9: Troubleshooting A.  Appliance Certifications   4 Troubleshooting Chart   23 B.  Mobile Home Approval   4 C.  Glass Specifications   4 Section 10: Service & Maintenance D.  Electrical Rating    4 A.  Shut-Down Procedure   24 E.  BTU & Efficiency Specifications  4 B.  Quick Reference Maintenance  24 C.  General Maintenance Procedures 25 Section 2: Special Warnings and Notes D.  Motors and Components  
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Super-Magnum Coal Stoker Stove Listing and Code Approvals 1  A.  Appliance Certification E.  BTU & Efficiency Specifications Model:  Super Magnum Coal Stoker Particulate Emissions  Laboratory: OMNI-Test Laboratories, Inc. Not Tested Rating:  Report No. 135-S-24-6.2 Type:  Solid Fuel Room Heater / Coal 5,000 - 103,000 / hr *BTU Input:   Burning Type. Heating Capacity: 2,500 sq. ft. or more Standard(s): UL1482, UL391, & ULC S627-00  Hopper Capacity: 110 lbs. This appliance is also approved for ins
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Super-Magnum Coal Stoker Stove Special Warnings and Notes 2  Carbon monoxide, referred to as CO, is a colorless, odorless  CO detectors are very sensitive and may  sound an alarm  gas that is produced during combustion of coal and other  for fumes other than CO or CO from sources other than  fuels. CO fumes are toxic and can be fatal. the stove such as car or lawn mower exhaust. The Super-Magnum is a natural draft system which relies  If the alarm sounds  on a properly designed chimney to remove
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Super-Magnum Coal Stoker Stove Getting Started 3  A. Design, Installation & Location B. Fire Safety Considerations Maintain the designated clearances to combustibles.  Insulation must not touch the chimney. You must  1.  Appliance Location maintain the designated air space around the chimney.  Consideration must be given to safety, convenience,  This space around a chimney is necessary to allow  traffic flow, and the fact that the appliance will need a  natural heat removal from the area. Insula
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Super-Magnum Coal Stoker Stove C. Component  Locations Coal Storage Hopper Removable Hopper Lid Heat Transfer Kit  Filler Plate Air Grill Load Door Ash Removal  Door Exhaust  Sensing  Probe (ESP) Heat Exchange  Cleaning Rod TM Verti-Flow Feeder Control Panel Distribution Air Filter Distribution Blower 3-90-02702R4_08/12                                                       Do Not Burn Wet Coal! 7                                                                                                     
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Super-Magnum Coal Stoker Stove D. Pre- Use Check List 1.  Place the appliance in a location near the WARNING  final installation and follow the procedures Inspect appliance and components for   below: damage. Damaged parts may impair safe  2. Open the appliance and remove all articles operation. • Do NOT install damaged components.  packed inside. Inspect all items for shipping • Do NOT install incomplete components.  damage. Notify dealer of any missing or • Do NOT install substitute components
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Super-Magnum Coal Stoker Stove Dimensions & Clearances 4  A. Appliance Dimensions 3-90-02702R4_08/12                                                       Do Not Burn Wet Coal! 9                                                                                                                                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Super-Magnum Coal Stoker Stove B.  Clearances To Combustibles E A C D F B E Parallel Corner  Inches Millimeters Inches Millimeters Installation Installation Back Wall To Unit Hopper 2                51 Walls to Unit Body 15              381 A E Side Wall To Unit 24              610 Walls to Flue Connector  24             610 B F Back Wall To Flue Connector 17              432 C  34              864 Side Wall To Flue Connector D C.  Floor Protection Requirements Floor protection must be of a non-
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Super-Magnum Coal Stoker Stove Chimneys and Venting 5  No part of the chimney connector may pass through  A.  Draft an attic or roof space, closet or other concealed space,  Draft is widely misunderstood.  It is important that you,  or through a floor or ceiling. Whenever possible, avoid  the stove operator, realize that draft is a variable effect,  passing the connector through a combustible wall; if you  not a given quantity. Stoves and chimneys do not have  must, use an approved wall pass-thr
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Super-Magnum Coal Stoker Stove Closest  Non-combustible cover, one  Combustible Minimum 2" (50mm) side only. If two covers are  Material Clearance to Brick used, each must be mounted  Hole with a minimum  on non-combustible spacers  clearance of  18" (450 mm)  Minimum 12"  at least 7/8" (21mm) away  between connector and wall. Liner (300mm) to Brick from the wall. Fire Clay Thimble Chimney  Connector Masonry Chimney Built to     1" (25mm) NFPA 211 Specifications.    Clearance Minimum 12" (300mm)
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Super-Magnum Coal Stoker Stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney,  have it thoroughly inspected and cleaned. Any faults  which make the chimney unsafe and unusable must be  repaired prior to use. These can include improper height,  structural defects, blockages, inadequate clearance to  combustibles, unsealed openings into other rooms of  the house, signs of creosote or smoke leakage, a loose  or absent clean-out door, or absence of a liner. 2. Vent
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Super-Magnum Coal Stoker Stove E.  Draft Test Procedure Because of the dangers associated with coal gases  and the potential for carbon monoxide release, It is  important to balance the airflow into the stove with the  draft in the flue. The combustion blower has a restrictor  plate attached to it, which must be adjusted upon  completion of the installation. The barometric damper,  if installed, must also be set to prevent over-drafting in  the appliance. Follow these steps to ensure safe and  e
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Super-Magnum Coal Stoker Stove Mobile Home 6  A.  Mobile Home Installation CAUTION Mobile home approval - U.S. only. Maintain structural integrity of mobile home: 1. An outside air inlet must be provided for  • Floor, wall, ceiling and/or roof. combustion air, and must remain clear of leaves,  Do NOT cut through: debris, ice, and/or snow. The outside air path must  • Floor joist, wall studs, or ceiling trusses. be unrestricted while the appliance is in operation. • Any supporting material that w
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Super-Magnum Coal Stoker Stove Appliance Set-Up 7  A.  Outside Air Attachment Parts and Supplies Needed: 1 piece of metal flexible  pipe, 3" X needed length. 1 Rodent Screen, Plus, you'll  want to obtain a trim ring for finishing around the pipe  on the inside wall.  1. Remove the knockout from the bottom shield.  There are three small areas that are not previously  cut. You can cut these tabs using a hacksaw or by  drilling them. A small rounded file will be helpful in  removing any sharp burrs
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Super-Magnum Coal Stoker Stove B.  Leveling the Appliance D.  Air Filter To adjust the leveling bolts, you must first loosen To ensure cleanliness of the air circulated through the  the locking nut. Turn the leveling bolt to the desired heat exchange, the Super Magnum is equipped with a  position, and re tighten the locking nut against the cast replaceable filter. The filter is located under the stove.  iron leg. To remove the filter, loosen the two thumb screws and  remove the cover. Slide the 
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Super-Magnum Coal Stoker Stove To Install the air grill, remove the existing painted  F.  Optional Door Trim Kit grill.  Then, using the same two screws and spring  The door trim kit includes a brushed stainless frame for  washers, install the brushed stainless grill. each door, and an air grill. To install the optional door  trim, you'll first need to remove the latch mechanism  from the door. The process is the same for each door. 1. Using a hex key wrench, loosen the set screw at  the latch. 
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        Super-Magnum Coal Stoker Stove Operating Instructions 8   A.  Fuel Specifications B.  General Operating Information The Super Magnum is designed for use with The Super Magnum's ESP control will maintain an  Anthracite "Rice" coal Only. Anthracite is a hard coal output level to fit your temperature demands. There are  which is mined mostly in the Eastern United States. two modes of operation; "Stove Temp" mode, where the  The post-mining process involves breaking the large control will maintain a
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Super-Magnum Coal Stoker Stove 2.  Circuit Board As stated previously, the circuit board is a microprocessor, which means it has the ability to "think" and adjust  itself based on both reported temperatures and demand temperature. The circuit board also has the ability to  self-diagnose when things are not happening as they should be.  Power Light Indicates power to the  Feed adjuster control. Sets the maximum feed  rate Status Light Will be lit in either stove  Test or room temp mode when  Runs