Resumo do conteúdo contido na página número 1 
                    
                        R
Cape Cod Woodstove
Beaverton
Tested and 
O-T L
Oregon USA
Listed by
C
CAUTION!
OMNI-Test Laboratories, Inc.
The baffle and kaowool blanket placement 
is crucial to the optimum performance 
of the stove.  Follow the steps on pg. 33 
carefully to ensure proper placement 
of baffles and kaowool at time of initial 
installation and following chimney clean-
ing.
This manual contains instructions for Installation, Operation & Maintenance
Please read this entire manual before you install and use your
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        R Cape Cod Wood Stove NOTES  My new Cape Cod wood stove.... SERIAL NUMBER: DATE PURCHASED: DEALERSHIP: DEALER PHONE #: ADDITIONAL INFORMATION  PERTINENT TO YOUR INSTALLATION: ATTACH SALES RECEIPT &  WARRANTY STUB HERE: This information will be necessary should your  stove require Warranty service. 32198A   February 15, 2002    32198A   February 15, 2002    Page 2                                                                                                                                       
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        R Cape Cod Wood Stove WELCOME Aladdin Hearth Products welcomes you to our tradition of excellence!  In choosing a Quadra-Fire appliance, you have  our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make  products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced  technology to achieve the optimum operation of ou
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        R Cape Cod Wood Stove TABLE OF  CONTENTS LISTINGS............................................................5 OPERATION SERIAL LABEL & LOCATON..........................6       PRE-USE CHECK.........................................26 DIMENSIONS.....................................................7      BURNING PROCESS ...................................26 CLEARANCES       WOOD SELECTION AND STORAGE........27       TOP VENT INSTALLATIONS .....................8      AIR  CONTROLS..................
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        R Cape Cod Wood Stove LISTINGS LISTINGS & CODE APROVALS These installation instructions describe the  cannot be unexpectedly cancelled.  If any assistance  installation and operation of the Cape Cod woodstove.   is required during installation, please contact your  This stove meets the U.S. Environmental Protection  local dealer. Agency’s 1990 particulate emission standards.  Inspect and clean vent system frequently in  The  Cape Cod is listed by OMNI-Test Laborato- accordance with the instructi
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        R Cape Cod Wood Stove LABEL LOCATION:  SAFETY LABEL BACK OF STOVE 32198A   February 15, 2002    32198A   February 15, 2002    Page 6 HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.  CAUTION:  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS LISTED ROOM HEATER, SOLID FUEL TYPE.   Tested and Beaverton Report #061-S-15-2 O-T L SERIAL NO. Listed by Oregon USA ALSO FOR USE IN MOBILE HOMES.  
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        R Cape Cod Wood Stove DIMENSIONS FRONT VIEW accessory parts 27" 26-1/2 29" SIDE VIEW 8-1/4" 22-1/2" 27-1/2" 16-1/4" 29-3/4" 16" 24-1/4" 32198A   February 15, 2002    32198A   February 15, 2002  Page 7                                                                                                                                                                                                                                                                                                            
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        R Cape Cod Wood Stove TOP VENT INSTALLATIONS CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES (In inches and  millimeters.) FIGURES 1, 2 & 3 SINGLE WALL: Six inch (6") diameter single wall, minimum 24 MSG black or blued steel connector pipe, with a listed  factory-built chimney suitable for use with solid fuels, or a masonry chimney, and the following clearances:                             A                  B                 C                  D                  E                  F              
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        R Cape Cod Wood Stove REAR VENT INSTALLATIONS CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES (In inches and millimeters)   FIGURE 4  In a Masonry Fireplace OR Through the Wall:  Six inch (6") diameter listed double wall air insulated connector pipe with  listed factory-built Class “A” chimney or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)  Additional specifications include a maximum 8" deep mantel without heat shield and the following clearances:                      
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        R Cape Cod Wood Stove FLOOR PROTECTION CLEARANCES The floor must be non-combustible or otherwise  adequately protected from radiant heat given off by  NOTE:  Additional floor protection is required on  the unit and from sparks and falling embers.  A layer  rear vent installations. For this type of installation the  of thin brick or ceramic tile over a combustible floor  floor protector must extend the length of the flue and 2"  is not sufficient.  to each side of the flue.  Floor protection can 
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        R Cape Cod Wood Stove ACCESSORIES The Cape Cod has several options available for installation and appearance.  These options are packaged  and sold separately and are listed below. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor  protection, before actually beginning the installation.  If you’re not using an existing chimney, place the stove  where there will be a clear passage for a factory-built listed chimney through the ceiling and roof
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        R Cape Cod Wood Stove CHIMNEY HEIGHT REQUIREMENTS INSTALLATION A masonry chimney or a factory-built chimney must  be the required height above the roof and any other nearby  obstructions.  The chimney must be at least three feet  FIGURE 6 higher than the highest point where it passes through the  2-10-3 RULE roof and at least two feet higher than the highest part  of the roof or structure that is within ten feet of the  2 ft Min (61cm) chimney, measured horizontally.  See Figure 6.  These  3 ft 
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        R Cape Cod Wood Stove FLUE  & VENTING SYSTEMS INSTALLATION WARNING:  ALWAYS FOLLOW CHIMNEY CONNECTOR MANUFACTURER’S INSTRUCTIONS FOR PROPER  INSTALLATION. CHIMNEY CONNECTOR IS TO BE USED ONLY WITHIN THE ROOM, BETWEEN THE STOVE AND CEILING  WALL, NEVER PASSING THROUGH A COMBUSTIBLE CEILING OR WALL.  THE CONNECTOR SHALL NOT  PASS THROUGH AN ATTIC OR ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR,  OR CEILING.  MAINTAIN MINIMUM CLEARANCES TO COMBUSTIBLES AS REFERENCED ON PAGES 9,  10 & 1
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        R Cape Cod Wood Stove MASONRY CHIMNEY INSTALLATION For optimal performance, masonry chimneys  used to vent this appliance should be lined with  Wood Stud 2"  (51mm)  a 6" stainless steel liner.  Installations into a clay  Clearance from  Fireclay liner 5/8"  chimney wall flue without a stainless steel liner may reduce  (16mm) Minimum or  efficiency, cause the glass to darken, and produce  Equivalent. excessive creosote. Ensure that a masonry chimney meets the  Header minimum standards of the Nat
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        R Cape Cod Wood Stove EIGHT INCH SOLID PACK CHIMNEY  INSTALLATION WITH METAL SUPPORTS AS A  THIMBLE FIRECLAY FLUE LINER  WITH AIR SPACE CONCRETE CAP RAFTER FLASHING 1" CLEARANCE  WITH FIRESTOP CEILING JOIST EAVE COMBUSTIBLE WALL 1" CLEARANCE THIMBLE, 12" OF BRICK SHEATHING FLOOR PROTECTOR AIRTIGHT  CLEANOUT DOOR FIGURE 8 FIGURE 9 32198A   February 15, 2002    32198A   February 15, 2002  Page 15                                                                                                       
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        R Cape Cod Wood Stove MASONRY CHIMNEY INSTALLATION First, make the frame for the thimble, ensuring  For the method of installation to a masonry  it is no smaller than 14" square, to maintain a 2" air  chimney shown in Figures 10 & 11, (on page 17),  space around the chimney section.  Attach the wall  it will be necessary to purchase an 8 inch inside  spacer to the chimney side of the frame.  Then insert  diameter, 12 inch long section of prefabricated listed  the frame into the opening, toe nail
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        R Cape Cod Wood Stove MASONRY CHIMNEY, CONT. INSTALLATION Min. Chimney Clearance  to Wall Spacer and  Combustibles - 2" (51mm) Min. Clearance  2" (51mm) 1" (25mm) Air Space  Chimney Flue Liner to Chimney Section Fireclay Liner  or Equivalent Chimney  Connector Chimney Section Trim Collar Wall Band Wall Spacer Masonry  Chimney  Constructed to  NFPA 211 FIGURE 10 Fire Clay Flue Liner with Airspace Masonry  Chimney Trim Collar Wall Spacer Chimney Section with 2"  (51mm) Clearance to  Combustibles W
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        R Cape Cod Wood Stove CONNECTION TO A MASONRY  INSTALLATION FIREPLACE There are several kits available to connect the stove to a masonry fireplace.  Look for a listed kit.  The kit  is an adapter which is installed at the location of the fireplace damper.  The existing damper may have to be  removed to allow installation of the kit.  The key points of this type of stove connection are that the connector  pipe must extend up the chimney above where the fire clay liner starts, and the areas of the
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        R Cape Cod Wood Stove CONNECTION TO A METAL  INSTALLATION PREFABRICATED CHIMNEY The other method is to install an exterior  chimney that runs up the outside of the residence.   When a metal prefabricated chimney is used,  See Figures 15 and 16.  (The components illustrated  the manufacturer’s installation instructions must be  may not look exactly like the system you purchase,  followed precisely.  It will be necessary to install the  but they demonstrate the basic components necessary  ceiling 
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        R Cape Cod Wood Stove CONNECTION TO AN INTERIOR   METAL PREFABRICATED CHIMNEY INSTALLATION FIGURE 13 Listed  Chimney Attic  Listed Cap Insulation  Combustible  Shield Maintain 2" (51mm) Storm Collar Ceiling  Specified  Joists Clearance Flashing Chimney Ceiling  Connector Listed Chimney To Stove FIGURE 14 Ceiling Support Combustible Wall Chimney  Connector * * Refer to Clearances             to Combustibles * Floor  Protector IMPORTANT ! FOLLOW THE MANUFACTURERS’  INSTALLATION INSTRUCTIONS AND  M