Resumo do conteúdo contido na página número 1 
                    
                         
 
 
 
Installation / Operator /  
Maintenance Manual for 
Etna, Elbrus, Vesuv & Meru 
 
 
 
Manufactured by:     Imported by: 
 
 
 
 
 
 
Frohnhof 9       PO Box 120 
91580 Petersaurach     Pound Ridge, NY 
Germany       USA 
T: ++49 9802 951473    T: 914 764 5679 
F: ++ 49 9802 9589909    F: 614 764 0465 
www.wolf-bavaria.com    www.wittus.com 
 
                                                                                                                                                   
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        2    Installation / Operator / Maintenance Manual      VESUV ETNA  Model: 0400 (Glass Sims) Model: 0300 (Glass Sims)    Model: 0402 (Tile Sims) Model: 0302 (Tile Sims)                                         ELBRUS MERU  Model: 0901 (Tiles)  Model: 0200    Model 0902 (Soap Stone)                                                                                                                                                                                                                            
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        3  IMPORTANT!    CAUTION: Please read this entire manual before you install and use your new room heater. For your safety, follow these  installation, operation and maintenance instructions exactly, without deviation. Failure to follow these instructions may  result in property damage, bodily injury, or even death. If this appliance is not properly installed, a house fire may result.  Contact your local building or fire officials about restrictions and installation inspection requirements in you
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        4  Congratulations on the purchase of your new woodstove manufactured by Wolf Bavaria in  Germany.    When you purchased your new woodstove, you joined the ranks of thousands of concerned individuals whose answer to  their home heating needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued  support to help you achieve the maximum benefit and enjoyment available from your new German woodstove.    It is our goal at Wolf Bavaria to provide you, our valu
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        5  TABLE OF CONTENTS    1. Planning Your Installation 7  1.1 Questions to Ask Local Building Officials 7  1.2 Smoke Detectors 7  1.3 Selecting a Location 7  1.4 Clearance from Combustible Walls 8  1.5 Floor Protection 9  1.6 Ventilation 9  1.7 Fresh Air 9  2. Installation 10  2.1 Installing Marble Accents 10  2.2 Baffle Bricks 10  2.3 Types of Chimneys 11  2.4 Acceptable Connector Pipe for Installations 11  2.5 Chimney Inspection 11  2.6 Chimney Height Requirements 12  2.7 Draft Requirements 12 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        6  12. Warranty 25  13. Replacement Parts List 26  13.1 Replace Tiles 26  13.2 Replace Glass 26  13.2.1 Replace glass and door handle on Etna, Vesuv and Elbrus 26  13.2.2 Replace glass and door handle on Meru 27  13.2.3 Replace baffel bricks on Etna, Vesuv, Elbrus and Meru 28          Testing/Listing    Appliance Type: Solid Fuel Room Heater   U.S. Test Standard: UL 1482   Canadian Test Standard: CAN/ULC-S627    EPA Exemption Certification    Packaging List    (1)  Installation / Operation / Ins
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        7  1. Planning Your Installation  1.1 Questions to Ask Local Building Officials  A correct installation is critical and imperative for reducing fire hazards and perilous conditions that can arise when wood  burning appliances are improperly installed. The installer must follow all of the manufacture’s instructions.    The installation of a wood burning appliance must conform to local codes and applicable state and federal requirements.  Familiarity with these requirements before installation is 
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        8  1.4 Clearance from Combustible Walls      WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES.      There are listed clearances for your stove which were determined in a laboratory test, using various “classes” of stove pipe  or chimney. Minimums are first established for the stove itself and then increased, based on how much heat is transferred  by each class of pipe.    Residential Standard (not approved for manufactured [mobile] homes)  Using single wall pipe connector to
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        9    1.5 Floor Protection  This appliance requires a non-combustible floor protection to protect against burning embers. If the floor is to be stone, tile,  brick, etc., it must be mortared or grouted to form a continuous, non-combustible surface. If a chimney connector extends  horizontally over the floor, protection must cover the floor under the connector and at least 2” (51 mm) to either side.  The floor protection must extend completely beneath the woodstove and to the front, sides, and rea
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        10  2. Indirect method:  for an appliance not certified for direct connection of outside combustion air, the outside air is  ducted to a point no closer than (12 in.) 300 mm from the appliance to avoid an adverse effect on the performance  of the appliance.  3. A mechanical ventilation system: if the house has ventilation system (air exchange or heat recovery):  a. The ventilation system may be able to provide sufficient combustion make-up air for the solid-fuel-fired appli- ance.   b. The house
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        11    2.3 Types of Chimneys  The chimney is a vital part of your woodstove installation. A properly built masonry chimney or a properly installed, fac- tory built chimney will provide a consistent draft under a variety of weather conditions (a smoking woodstove is usually  caused by a chimney problem). The minimum stove flue size is 6 inches (152 mm) in diameter, which is approximately 28  square inches (711 square mm). The maximum flue size should be no more than three times the cross sectional
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        12  Vapor Barrier At Chimney Penetration  Install all venting components according to the vent manufacturer’s installation instructions. Ensure that there is an effec- tive vapor barrier at the location where the chimney penetrates the exterior of the structure. This can be accomplished by  applying a non-hardening, waterproof sealant to the following components:    ? Around the chimney at the point where the storm collar will meet the chimney, just above the flashing.  ? Along the vertical seam
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        13                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        14    2.8 Combustible Wall Chimney Connector Pass-Throughs  Method A. 12” (305 mm) Clearance to Combustible Wall Member: Using a  minimum thickness of 3.5” (90 mm) brick and a 5/8” (16 mm) minimum  wall thickness clay liner, construct a wall pass-through. The clay liner must  conform to ASTM C315 (Standard Specification for Clay Fire Linings) or  its equivalent. Keep a minimum of 12” (305 mm) of brick masonry between  the clay liner und wall combustibles. The clay liner shall run from the brick 
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        15  3. User’s Guide  3.1 Hand Protection  Please use a protective glove when opening the doors!!! You can then add wood while the handle is hot  3.2 Technical Data and Dimensions    VESUV ETNA                                                                                                                                                                                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        16      ELBRUS    MERU                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        17    Heat Output Dimensions Flue Diameter Center Height  Weight Area Heated   h x w x d (inner) rear design  Model  3  (kW) (mm) (mm) (mm) (kg) (m )  VESUV 8 1478 x 828x 636 150 1250 285 180  ETNA 8 1478 x 992x 636 150 1250 260 180  8 1478 x 702x 619 150 1250 290 180  ELBRUS  160 (ceramic)  MERU 8 1024 x 598 x 473 150 858 180  190 (stone)  Chimney Data Average Wood Use – Single Load    3-4 pieces of wood, 15-20% moisture  Draft Average Flue Gas Flue Gas Heat  2 o  (Pa) (cm ) (g/s) ( C) (kg/h)  
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        18    3.5 Acceptable Fuel  Acceptable fuel sources are pieces of wood with a length of 30 cm (12”) and a diameter of 10 cm (4”), as well as wood  briquettes.   Only air-dried wood should be used. The burning of waste materials, in particular synthetic materials, is not permit- ted, according to federal laws regulating emissions. In addition, this causes damage to the fireplace and chimney. Air- dried wood will achieve a maximum water content of 30% after at least 1 year (soft woods) and/or 2 yea
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        19    5. Fresh Air Supply  The woodstove can only be installed in rooms with a sufficient supply of fresh air intake for combustion purposes. This is  true of rooms that have at least one exterior door or one window that can be opened. Rooms that are connected to the same  fresh air network, i.e. rooms within the same residence or common areas, are also appropriate for installation.    The woodstove requires    approx. 40m³ fresh air per hour for combustion.      With newer, well-insulated house
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        20        6. Operating Your Woodstove  Etna, Elbrus und Vesuv  6.1 Regulating the Heat   Draft controls to regulate secondary air are located under the door on the  right and left sides respectively. Pull the control towards you to open.   .  1) Secondary Draft Control  ash    drawer    1      MERU:  Close       Open             Pull = Open  1    Press = Close                  The secondary draft control lever regulates the amount of air that is needed to reburn exhaust gases that are produced i