Resumo do conteúdo contido na página número 1 
                    
                         
 
 
TRADITION SERIES P24 
 
 
                   
                  
 
                        P24FS                                                                           P24I 
 
 
 
OWNER’S MANUAL 
 
 
• Warning: If your appliance is not properly installed a house fire may result. For your safety, follow 
 
the installation directions. Contact local building or fire officials about restrictions and installation 
inspection requirements in your area.  
• PLEASE read this entire manual befo
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        2 INTRODUCTION  Thank you for purchasing the Breckwell Pellet Burning Stove. You are now prepared to burn  wood in the most efficient, convenient way possible. To achieve the safest, most efficient and  most enjoyable performance from your stove, you must do three things: 1) Install it properly;  2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you  do all three.     PLEASE read this entire manual before installation and use of this pellet fuel-burning
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        SAFETY PRECAUTIONS 3    Do not operate your stove if you smell smoke Never try to repair or replace any part of the  coming from it.  Turn it off, monitor it, and call your stove unless instructions are given in this  dealer. manual. All other work should be done by a  trained technician.     Never use gasoline, gasoline-type lantern fuel, Do not throw this manual away. This manual  kerosene, charcoal lighter fluid, or similar liquids to has important operating and maintenance  start or “freshen
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        4 TABLE OF CONTENTS      INTRODUCTION --------------------------------------------------------------------------------------------- 2  SAFETY PRECAUTIONS ---------------------------------------------------------------------------------- 3  SPECIFICATIONS ------------------------------------------------------------------------------------------- 5  INSTALLATION --------------------------------------------------------------------------------------------- 5   Preparation ---------------------------
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        INSTALLATION 5  SPECIFICATIONS  FREESTANDING:  Width: 26”  Height: 33 ¼”  Depth: 30 7/8” (excluding ash lip)  Weight: 325 lbs.  Flue size: 3” or 4”  Hopper Capacity: Up to 65 lbs.    (this can vary widely depending on pellet size, length, and diameter)    EPA status: exempt  SIDEWALL CLEARANCES   Burn time: 1 lb. to 5 lbs. per hour    BTU range: 8,200 to 50,000    FIGURE 1  Approved installations: mobile home, alcove, conventional    FIREPLACE INSERT:  Width: 22” (at fireplace rear)             
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        6 INSTALLATION  COMBUSTION AIR SUPPLY  For a mobile home installation the stove must be connected to an  outside source of combustion air. A 2” inside diameter metallic pipe,  either flexible or rigid, may be attached to the inlet at the stove’s rear  (refer to figures 5 & 6). A rodent guard (minimum ¼” wire  mesh)/wind hood must be used at the terminus (refer to figure 7). All  connections must be secured and airtight by either using the  appropriately sized hose clamp and/or UL-181-AP foil tap
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        INSTALLATION 7    Equivalent Vent Length (EVL)      The longer the run of pipe in your installation (both with insert and    freestanding), the more restriction there is in the system. Therefore,  larger diameter pipe should be used.      • Use 4” pipe if you have more than 15 feet of equivalent vent    length.      • Horizontal runs shall not exceed 10’ of EVL.    • Recommended vertical runs to be minimum of 8’.      • To calculate EVL, use the following conversions:    90º elbow or “T”  = 5 eq
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        8 INSTALLATION  B. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to  Figure 9a & 9b)    NOTE: Follow L-Vent chimney manufacturer’s instructions.    OPTION:  To achieve a center vertical installation a 45º elbow and a  clean-out tee can be used to offset the pipe from the exhaust outlet  to the rear center of the stove (see figure 9a). You can also use the  P24FS Vertical Install Kit (part # A-VIK) (see figure 9b).    OPTION: Install L-Vent elbow in place of clean-out tee. Locate  stove. Drop plumb b
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        INSTALLATION 9  C. VERTICALLY INTO EXISTING CHIMNEY SYSTEM    Adapters are available to adapt from 3” L-Vent to 6” or 8” Class-A  chimney. (Figure 10a)    As an alternative, 3” or 4” L-Vent can be run inside existing chimney  to termination. (Figure 10b)  This is the preferred method.    Follow guidelines for equivalent vent length.        FIGURE 10a        FIGURE 10b                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        10 INSTALLATION  D. VERTICALLY INTO EXISTING MASONRY    FIREPLACE    NOTE: Follow L-Vent chimney manufacturer’s  instructions.    1. Have the masonry chimney inspected by a qualified  chimney sweep or installer to determine its structural  condition.    2. You will need a pipe length equal to the chimney  height from the hearth. If outside combustion air is to  be used, you will need a pipe length equal to the  chimney height plus 18 inches.    3. Install a blanking plate and the chimney pipe, a
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        INSTALLATION 11  INSERT INSTALLATIONS      Insert installations must be vented with 3” or 4” pipe.  Pipe may be single wall stainless steel flexible pipe.  Vent may terminate within chimney beyond a blanking  plate or extend to the chimney top. See  “COMBUSTION AIR SUPPLY” for outside air access  information.    The fireplace and chimney should be cleaned  thoroughly before starting the installation. We suggest  painting the interior of particularly old and dirty  fireplaces to seal any odors. I
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        12 INSTALLATION  B. WHEN VENT PIPE EXTENDS TO   CHIMNEY TOP   (Refer to Figure 15)      1. You will need a pipe length equal to the   chimney height (from hearth) plus 6 inches. If   outside combustion air is to be used, you will   need a pipe length (see “COMBUSTION AIR   SUPPLY”) equal to the chimney height plus   12 inches.      2. Attach cerablanket wrap to the end of vent   pipe that will connect to the stove. Use 12-  inch lengths of light gauge metal wire (not   included) or metallic tape
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        INSTALLATION 13  D. AS A BUILT-IN FIREPLACE    Figures 16 and 17 describe a P24 installation  vented into either a special chase built outside  an outer wall or a false inside wall. This is  especially suited for new construction or  remodeling.    The equipment compartment (sides and rear of  the stove in fireplace) must be enclosed per the  applicable electrical standards.    NOTE: Floor protection for Built-in raised  hearths requires a continuous sheet beneath to  prevent the possibility of 
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        14 INSTALLATION  E. INSTALLATION IN TO A FACTORY BUILT    (METAL) FIREPLACE            (Refer to figure 18)      When installing into a factory built fireplace, the firebox    must accept the insert without modification other than  removing bolted or screwed together pieces such as    smoke shelf/deflectors, ash lips, screen or door tracks    and damper assemblies. These items must be reinstalled  to restore the fireplace to its original operating condition if    the insert is removed and not re
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        OPERATION 15  PANEL CONTROLS (See Figure 19)        The blowers and automatic fuel supply are controlled from a panel on the left-hand side of the P2000.  The control panel functions are as follows.        a. ON/OFF SWITCH      • When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will    stay on for at least 10 and up to 15 minutes, depending on when Proof of Fire is reached. The  fire should start in about 5 to 7 minutes.    • The green light located
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        16 OPERATION  PROPER FUEL    THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in  diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning  wood in forms other than pellets is not permitted. It will violate the building codes for which the stove has been approved and will  void all warranties. The design incorporates automatic feed of the pellet fuel into the
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        OPERATION 17  RE-STARTING A WARM STOVE    If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.      IF STOVE RUNS OUT OF PELLETS    The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes.  After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes.  After the 10 minutes the “3” light on the bar graph will flash an
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        18 THERMOSTAT INSTALLATION  OPTIONAL THERMOSTAT        A thermostat may help you maintain a constant house temperature    automatically. A millivolt thermostat is required. A fixed wall mount or    Breckwell’s hand held model can be used. The control panel can be  set up two ways to operate your stove in thermostat mode.     THERMOSTAT INSTALLATION        • A MILLIVOLT THERMOSTAT IS REQUIRED.     • Unplug stove from power outlet.    • Remove control board from stove.  • The two thermostat wires 
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        OPERATION 19    OPERATING SAFETY PRECAUTIONS    PLEASE READ THIS!    a. Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns.    b. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup in firebox,  immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door, change the damper  setting or tamper with any controls on the stove. Wait until firebox clears, and blowers shut down, do as  instructed in 
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        20 MAINTENANCE  FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT   IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER CLEAN WHEN  HOT.    NOTE: Inspect burn pot periodically to see that holes have not become plugged, if  so, clean thoroughly.    ASH REMOVAL      Ashes should be placed in a metal container with a tight-fitting lid. The closed    container or ashes should be placed on a noncombustible surface or on the    ground, well away from all combustible materials pending final dis