Resumo do conteúdo contido na página número 1 
                    
                        MUSTANG SURVIVAL
�
INFLATABLE VEST 
TM
WITH LIFT 
Owner’s Manual
TM
MD0450 22 Inflatable Vest with LIFT
Hydrostatic Inflation Model - Manual with Automatic Backup 
TM 
SecureZIP US Patent No. 6,832,415 and Patents Pending                                                                                                                                                                                                                                                                                       
                    
                    Resumo do conteúdo contido na página número 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        CONTENTS Page  1 Introduction    1 Why are PFDs Required Safety Equipment?    2 What is an Inflatable PFD?    3 Instructions for Use     3 Component Inspection Instructions     4 Readiness Checklist     5 Donning Instructions     6 Inflation      8 In-water Adjustments     9 Special Considerations for Automatic Devices       10 Deflation     10 Usage Below Freezing     11 Re-arming Your PFD      15 Auto/Manual Conversion Cap (MA7219) Instructions     15 Conversion Instructions     17 Repacking  
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        INTRODUCTION The MD0450 22 requires user involvement to ensure a level of safety  equal to other inflatable PFDs. Knowledgeable users increase their safety  significantly by wearing and using these PFDs as prescribed in this  owner’s manual. General - This Inflatable PFD will turn most wearers from a face  down to a face up position and provide support suitable for offshore  conditions. See page 11 for re-arming instructions.  This Inflatable PFD was designed to be more comfortable and less  res
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Inflatable PFD so you know what to do in an emergency. WHAT IS AN INFLATABLE PFD? Congratulations on the purchase of your Inflatable Vest with Patent  TM TM Pending LIFT [Life-saving Inflatable Flotation Technology]. LIFT is  different from all other inflatable PFD’s. In general, inflatable PFD’s are  designed to suspend a user’s head above water to prevent drowning.  TM The Inflatable Vest with LIFT provides freeboard that far exceeds the  TM minimal 3” generally provided. LIFT elevates you to 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        INSTRUCTIONS FOR USE This manual supplies instructional, maintenance and safety information  for model MD0450 22 unless specified otherwise. The model number is  listed on the label. FIGURE 1 MD 0450 U np ack ed Or al I nf l a t o r C o v er P an el W ind o w C h est S t r a p H y d r o s ta t ic C h es t V el c r o T ab I nf l a t or F O L D #1 F O L D #1 B u c k l e FO LD #3 FO L D # 3 F O LD # 2 FO LD #2 B ea ded W a i st B el t H a nd l e R i g h t L o b e F r o n t B u c k l e L e ft L o b 
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        RE-ARMING YOUR PFD (p. 11).  NOTE: The single point indicator must be green before  proceeding. 2) Open the cover at wearer’s right-hand side of the chest and lay the  device flat.  3) Ensure the oral-inflation dust cap is in the stowed position (Fig. 22). 4) Ensure the single point indicator is green and the beaded handle is  attached to it’s Velcro tab; secure the zippers on the Inflatable Vest  TM with LIFT (see Repacking, p. 17). 5) Ensure the date on the inflator is not five years or older 
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Donning Instructions It is important that the PFD is properly adjusted to fit the person wearing  it. An incorrect fit or improper fastening of attachments could reduce its  effectiveness. TM 1) Put the Inflatable Vest with LIFT on just like a jacket (Fig. 3). If  TM the Inflatable Vest with LIFT is already inflated prior to donning,  it may be excessively tight while donning. If so, expel some air by  TM depressing the oral tube valve, don the Inflatable Vest with LIFT ,  TM and refill Inflatab
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        3) Fasten the middle buckle (Fig. 4). Adjust the middle belt to a secure  fit using the front adjuster on the belt.  FIGURE 4 IMPORTANT: Ensure the  chest buckle is fastened,  when inflated (Fig. 4). 4) Feed the loose end of the waist belt into the belt opening in the  storage pocket (Fig. 5). FIGURE 5 Inflation It is recommended that the following procedures be followed to inflate  TM your Inflatable Vest with LIFT . Manual Inflation 1) Activate the inflation system by grasping the beaded handl
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        firmly downward. The PFD should fully inflate within 5 seconds (Fig.  6).  NOTE: Deflation may occur if the CO cylinder is removed  2 TM while the Inflatable Vest with LIFT is inflated. FIGURE 6 2) Fasten the chest straps (Fig. 7) and adjust to a snug fit. Important: Ensure the chest buckle is fastened, when inflated. FIGURE 7 Fastened  Chest Strap Automatic Backup Inflation  Inflation will occur automatically within 5 seconds after the inflator is  immersed in water. Hydrostatic pressure opens 
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        NOTE: Hydrostatic inflator must be submerged in at least 4 inches  of water to activate the inflator. NOTE: When inflated, the carbon dioxide (CO gas) used to inflate  2 PFDs will slowly escape through the cell over time. A slight  reduction of pressure will be observed after several hours of  inflation. Topping up by oral inflation may be required in the  event of prolonged immersion. Oral Inflation TM Properly armed and inspected Inflatable Vest with LIFT PFDs will inflate  when manually or au
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        In-water Adjustments Follow these instructions to adjust the waist belt, when wearing the  TM Inflatable Vest with LIFT in the water. To tighten: a. Grasp the loose end with the left hand. Pull the webbing to your  right side (away from the buckle) (Fig. 9). b. Simultaneously grasp the waist belt along the body with the right  hand (approximately 6 inches to the right of the buckle), and feed  the webbing into the buckle. FIGURE 9 To loosen: a. Simultaneously grasp and hold the waist belt with t
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Special Considerations for Automatic Devices The PFD might not be armed when needed, either knowingly or unknow- ingly. Premature automatic inflation causes several risks that you must  address to avoid drowning. Much less common but also important are: 1) Double inflation (CO cylinder inflation after full oral inflation) could  2 damage the PFD, 2) Inflation when stored in a tight space could damage the PFD, and 3) The PFD could inflate when you are in an awkward place or position.  If this PFD
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Usage Below Freezing When the temperature is below freezing, a fully discharged cylinder  TM may not adequately inflate your Inflatable Vest with LIFT Under these  TM conditions use the oral inflator to top-up the Inflatable Vest with LIFT TM It may be neccessary to manually release the Velcro tabs, located at the  bottom of the left and right panel covers, for full inflation because oral  inflation may not provide sufficient pressure to open the tabs. Re-arming Your PFD NOTE: A valid re-arm kit
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        2) Insert the metal key between the black locking ring and labeled  yellow cap. Turn the key counter-clockwise (Fig. 13). FIGURE 13 Key Locking Ring 3) Turn the black locking ring counter-clockwise and lift off the cap  (yellow inflator operating head Fig. 14). Dispose of the used cap. FIGURE 14 Cap 4) Squeeze the sealing ring to elongate and remove the inflator body  (Fig. 15). TM Inflatable Vest with LIFT Owner’s Manual  12                                                                       
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        FIGURE 15 Red Indicator Inflator Body Sealing Ring 5) Dispose of the used inflator body. FIGURE 16 Red Indicator Trash 6) Check that the new inflator body indicator is green. Insert the new  inflator body with CO cylinder pointing upward inside the Inflatable  2 PFD (Fig. 17). Let the sealing ring rest on the adapter around the four  lugs. FIGURE 17 Green Indicator Caution:  Do not turn  the center  shaft 13 MUSTANG SURVIVAL                                                                        
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        7) Now check the new manual/automatic cap as follows (Fig. 18):   1.  Is the single point status indicator showing green?   2.  Is the expiry day OK?  If YES is the answer to both questions, then proceed as follows. If the  answer is NO to either question, get a new cap. FIGURE 18 Water  Inlet  Valve Single  Point  Indicator Expiry 8)  Hold the CO cylinder through the fabric of the Inflatable Vest with  2 TM   LIFT (Fig. 19). Position the replacement cap with the water inlet  valve pointing to t
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        9) While pressing FIRMLY onto the inflator body, turn the BLACK  locking ring clockwise into the locked position (Fig. 21). Pull on the  cap to make sure it has locked onto the inflator body. FIGURE 21 Lanyard Black  Locking  Ring 10) Check: To see that the single point status indicator on the cap is  green; the pull to inflate lanyard is present and that the locking ring  is locked.  11) Ensure the beaded handle is fed through the pocket opening and  fastened to the Velcro tab (Fig. 39). TM 12)
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        2) Fasten, by tying, the conversion cap lanyard to the loop in the pocket  immediately in front of the inflator after passing it through the  opening in the cover (Fig.22).  FIGURE 22 O p e n i n g L a n y a r d F O L D # 1 F O L D # 3 F O L D # 2 R i g h t L o b e C o n v e r s i o n C a p 3) Position the conversion cap over the inflator’s hydrostatic valve  opening. The conversion cap’s metal clip should be placed along the  top of the inflator’s hydrostatic valve (Fig.23). FIGURE 23 4) Secure
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        CONVERSION CAP REMOVAL  Once the conversion cap is removed, the MD3196 becomes an automatic  inflation device. Firmly pull the conversion cap lanyard to remove the  conversion cap (Fig.25).  NOTE:Do not pull inflation lanyard when removing conversion cap FIGURE 25 To remove the conversion cap when packed, pull the conversion cap  lanyard out from the opening of the cover of the LP’s right lobe. Visually  confirm the conversion cap has been removed from the valve opening.  Place the conversion ca