                         Owner’s Manual
MD3183 Inflatable PFD  
Hydrostatic Inflation Model - Manual with Automatic Backup  
Recreational: USCG Approved Type II
Uninspected Commercial Vessels: USCG Approved Type V
MD3184 Inflatable PFD 
Hydrostatic Inflation Model - Manual with Automatic Backup  
with Harness 
Recreational: USCG Approved Type V
 
 
DO NOT REMOVE PRIOR TO SALE                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        CONTENTS Page  1 Approval Conditions and Carriage Requirements    2 Note to Uninspected Commercial Vessel Operators    2 Why are PFDs Required Safety Equipment?    2 What is an Inflatable PFD?    3 Instructions for Use     4 Uninspected Commercial Vessel Use       4 Component Inspection Instructions     4 Readiness Checklist     5 Sizing and Fit     5 Donning Instructions     5 Inflating Your Inflatable PFD     7 Special Considerations for Inflatable Devices      7 Deflating the Inflatable PFD  
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        APPROVAL CONDITIONS AND CARRIAGE REQUIREMENTS Approved for recreational use by the U.S. Coast Guard (USCG) as a      Type II (Model MD3183), or Type V (Model MD3184) Personal Flotation  Device (PFD). Neither are approved for water skiing or other high impact,  high-speed activities. Model MD3184 has Type II performance but is  approved as a Type V PFD because it has a built-in sailing harness that  can cause injury if not properly used. A separate section titled “SAILING  HARNESS” (p. 15) discus
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        less restrictive to wear than inherently buoyant PFDs. When worn, used  and serviced according to this owner’s manual, this PFD can greatly  increase your chances of survival in the water. Not recommended for  non-swimmers or weak swimmers. Users of inflatable PFDs must be  at least 16 years old. NOTE TO UNINSPECTED COMMERCIAL VESSEL  OPERATORS The operator of the vessel is required to provide the following user  information to each person on board. Inflatable PFDs will not provide any buoyancy 
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        CO gas cylinder. The Inflatable PFD is designed to offer maximum  2 mobility with minimum bulk. The Inflatable PFD can be inflated either  automatically by water immersion, manually by jerking a pull-tab, or  orally by mouth. It is recommended that you familiarize yourself with the  procedures outlined in INSTRUCTIONS FOR USE (p. 3). INSTRUCTIONS FOR USE This manual supplies instructional, maintenance and safety information  for both models (MD3183, MD3184). The model number is listed on the  un
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Uninspected Commercial Vessel Use This Inflatable PFD is not approved for “hot work” and care must be  taken to avoid damage from abrasion and sharp objects. Component Inspection Instructions 1) Examine the single point status indicator through the window panel  (Fig. 1). Ensure the indicator is green. If the indicator is red, the  mechanism has been fired or is incorrectly fitted (see Re-arming Your  PFD, p. 9). NOTE: The single point status indicator must be green before  proceeding. 2)  Undo 
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        about the readiness of your Inflatable PFD. Sizing and Fit This PFD provides a minimum of 33.7 lbs of buoyancy when inflated and  is designed for wearers over 16 years of age, with a chest range of 30-52  inches (76-112 cm) weighing over 80 pounds (36 kg). Donning Instructions It is important that the Inflatable PFD is properly adjusted to fit the  person wearing it. An incorrect fit or improper fastening of attachments  could impede its effectiveness. 1) All belts and straps are already threade
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        1) Manual Inflation  Activate the inflation system by jerking firmly downward on the pull- tab (Fig. 4). The Inflatable PFD should fully inflate within 5 seconds. FIGURE 4 Automatic Inflator  2) Automatic Backup Inflation   When the inflator is lowered more than about 4 inches in the water,  then the hydrostatic valve opens and lets the water meet the water  sensitive element that in turn releases a stainless steel coil spring.  The spring then drives a needle into the end of the gas cylinder,  
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        NOTE: Oral inflation may cause the Inflatable PFD to break-out  suddenly (loudly) if any of the zippers are closed.  ii.  Locate the oral inflation tube by opening the wearer’s left front  panel of the Inflatable PFD. Remove the dust cap from the end of  the oral tube and blow into the tube until the Inflatable PFD is fully  inflated. FIGURE 5 Special Considerations for Inflatable Devices  The Inflatable PFD might not be armed when needed, either knowingly  or unknowingly. Inadvertant inflation 
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        cap will not lock in the deflate position so it is necessary to hold it in  place (Fig. 5).  2) Gently squeeze the Inflatable PFD until all air or gas has been  expelled. To avoid damage; do not wring or twist the Inflatable PFD.  Put the inflation tube dust cap back in its stowed position on the  oral inflation tube (Fig. 6). IMPORTANT: Ensure all air has been removed from the PFD. 3) Examine the single point status indicator (Fig. 1). If the indicator is  red, the mechanism has been fired and 
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Re-arming Your PFD NOTE: A valid re-arm kit (MA7214) is required for this procedure.  1) Place the Inflatable PFD (Personal Flotation Device) on a smooth, flat  surface and wipe off any water. Access the inflator by reaching under  the cover and pull it toward you, turning the cell and cover inside- out to fully expose the inflator for re-arming. Hold the CO cylinder  2 through the fabric, using one hand (Fig. 8). FIGURE 8 2) Insert the metal key between the black locking ring and labeled  yello
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        FIGURE 10 Cap 4) Squeeze the sealing ring to elongate and remove the inflator body  through the sealing ring (Fig. 11).  FIGURE 11 Red Indicator Inflator Body Sealing Ring 5) Dispose of the used inflator body. FIGURE 12 Red Indicator Trash 6) Check that the inflator body indicator is green. Insert the new inflator  body with CO cylinder pointing upward inside the Inflatable PFD  2 (Fig.13). Let the sealing ring rest on the adapter around the four lugs. 10                 Inflatable PFD Owner’s M
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        FIGURE 13 Green Indicator Caution:  Do not turn  the center  shaft 7) Now check the new manual/automatic cap as follows (Fig. 14):   1.  Is the single point status indicator showing green?   2.  Is the expiry day OK?   If YES is the answer to both questions, then proceed as follows. If the  answer is NO to either question, get a new cap. FIGURE 14 Water  Inlet  Valve Single  Point  Indicator 8)  Hold the CO cylinder through the fabric of the Inflatable PFD (Fig.  2 15). Position the replacement 
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        FIGURE 15 FIGURE 16 9) While pressing FIRMLY onto the inflator body, turn the BLACK  locking ring clockwise into the locked position (Fig. 17). Pull on the  cap to make sure it has locked onto the inflator body. FIGURE 17 Black  Locking  Ring 10) Check: To see that the single point status indicator on the cap is  green; the pull to inflate lanyard is present and that the locking ring  is locked. 11)  Refold the Inflatable PFD in accordance with the Repacking section  (p. 13). 12                 
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Repacking If your Inflatable PFD has been used and/or the hydrostatic inflator  replaced, always inflate through the oral tube and check that it stays  inflated at least overnight. With the dust cap in the top of the oral tube,  gently squeeze the Inflatable PFD until all air or gas has been expelled  (Fig. 6). Do not wring or twist the Inflatable PFD. Put the oral tube dust  cap back in its stowed position on the oral tube (Fig. 7). Let the life  jacket dry before packing.  IMPORTANT: Ensure al
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        FIGURE 22 FIGURE 21 C D 4) Fold over the top side (E) and cover (F). FIGURE 23 FIGURE 24 E F 5)  Mustang Survival uses advanced 2-step zippers. ZIP 1 - Reset the  zipper by pulling the slider (G) around the top to the Velcro™ tab  (H). ZIP 2 - Close by pulling the slider (G) in the opposite direction  to the end the zipper (Fig. 26). Ensure that the Inflatable cell does  not get caught by the zipper when closing.  FIGURE 25 FIGURE 26 G H H G 14                 Inflatable PFD Owner’s Manual Infla
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        6)  Fasten the Velcro™ tab (H) to keep zipper closed. FIGURE 27 H 7)  ZIP 1 - Reset the 2-step zipper by pulling the slider (I) to the  Velcro™ tab (H). ZIP 2 - Close by pulling slider (I) in the opposite  direction to the end the zipper (Fig. 29). Ensure that the Inflatable  cell does not get caught by the zipper when closing. FIGURE 29 FIGURE 28 H H I I 8)  Use a finger to push the zipper ends into the openings at the bottom  of the the packed Inflatable PFD (Fig. 30).  FIGURE 30 14           
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        9)  Ensure the pull-tab (J) is on the outside of the folded Inflatable PFD.  Fig. 30 depicts a correctly folded Inflatable PFD. FIGURE 31 J Sailing Harness  CAUTION: Use only as a sailing harness.  Models with a sailing harness (MD3184) are designed to prevent the  user from falling overboard when used with a tether with an under-load  quick-release hook and have been designed and tested in accordance  with Offshore Racing Council (ORC) requirements. Care and attention  must be taken to ensure t
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        quick-release under-load hardware. This harness has not been  designed for fall arrest, lifting or climbing and should not be  relied upon in any of these instances. US Coast Guard approval does not apply to this harness and the  potential for injury has not been assessed. Chest Buckle FIGURE 32 D-Ring Chest Belt Webbing Tether Quick Release Lanyard Webbing IS YOUR PFD IN GOOD AND SERVICEABLE  CONDITION? Check your Inflatable PFD between outings to be sure that it is properly  armed; that it is 
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        1) Before Each Use:   i)  Examine the single point status indicator through the window  panel, ensuring it is green. If the indicator is red, the mechanism  requires service. See Re-arming Your PFD, p. 9.   ii)  Ensure the manual pull-tab is accessible.   iii)  Visually examine your Inflatable PFD for damage or excessive  abrasion, wear, tear or contamination. Particular attention must be  paid to the stitching, straps and hardware. If in doubt, send it to your  Mustang dealer for evaluation and