Resumo do conteúdo contido na página número 1 
                    
                        1
INSTALLER:  LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER:  RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND
OPERATION INSTRUCTIONS
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CR97-003  ●  CAN-2.21-M85  ●  IAS US. 4-96
OUTDOOR
GSST8N
NATURAL GAS
GSST8P
PROPANE
Certified for Canada and United States using ANSI/CSA Methods.
SAFETY INFORMATION
!
WARNING
If the information in these instructions are not 
followed exactly, a fire or explosion may result 
causing property dama
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        2 TABLE of CONTENTS  PG 2-5 INTRODUCTION  12  OPERATING INSTRUCTIONS         Warranty     General Instructions  13  MAINTENANCE     General Information / Rates and Effi ciencies     Cleaning     Care of Glass and Plated Parts       Dimensions 13   ADJUSTMENTS     Gas Pressure Adjustment 5-7   INSTALLATION        Venturi Adjustment     Gas Installation     Flame Characteristics     Electrical Connection     Clearance to Combustibles 14  REPLACEMENTS     Replacement Parts 8-11  FINISHING     Access
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        3 NAPOLEON® products are manufactured under the strict Standard of the world recognized  ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained  craftsmen who take great pride in their work. Th e burner and valve assembly are leak and test-fi red at a  quality test station. Once assembled the complete fi replace is thoroughly inspected by a qualifi ed technician  before packaging to ensure that you, the customer, r
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        4 GENERAL INSTRUCTIONS THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER  to conform with local  codes. Installation practices vary from region to region and  it is important to know the specifi cs that apply to your area,  for example: in Massachusetts State: • The appliance off valve must be a “T” handle gas cock. • The fl exible connector must not be longer than 36 inches. • WARNING: This product must be installed by a licensed plumber or gas fi tter when installed wit
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        5 DIMENSIONS FIGURES 1a-c 9 /16 7 11 /16 3 49 /8 36 15 ELECTRICAL GAS LINE  1 13 1 /2 ACCESS ACCESS INSTALLATION GAS INSTALLATION Note: All gas connections must be contained within the  appliance when complete. 1.  The appliance is designed to accept a 1/2” gas supply line. The  appliance is equipped with a 1/2” manual shut-off valve. 2. The access to the gas inlet is located in the bottom of the  cabinet. 3. The shut off valve / fl ex connector assembly must always be  W385-0380 contained within
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        6 ELECTRICAL CONNECTION FIGURE 3 ! GAS WARNING VALVE RISK OF ELECTRIC SHOCK! IGNITOR Control and valve operate with 110v. Do NOT use the appliance if any part has been  IGNITOR 12 3 4 under water.  Call a qualifi ed service technician  WIRE IMMEDIATELY to have the appliance inspected  for damage to the electrical circuit. BROWN HARD WIRING CONNECTION B L IT IS NECESSARY TO HARD WIRE THIS A G C CONTROL MODULE R W APPLIANCE. K SWITCH O H U This appliance must be electrically connected and  I N T Il
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        7 C G D G I E K H A J B F B FIGURE 5 INSTALLATIONS CANADA U.S.A. A 8 INCHES 8 INCHES Clearance above grade, veranda porch, deck or balcony. B 12 INCHES 9 INCHES Clearance to windows or doors that open.   C 12 INCHES* 12 INCHES* Clearance to permanently closed windows.  D 18 INCHES** 18 INCHES** Vertical clearance to ventilated soffi t.   E 12 INCHES** 12 INCHES** Vertical clearance to an unventilated soffi t.   Clearance to an inside combustible corner wall or protruding  F 1 INCH 1 INCH combustib
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        8 FINISHING TMCSS MOUNTING CABINET INSTALLATION ! WARNING Before starting the installation remove the  INSTALLATION 1 protective layer from all three components that  TEMPLATE make up the GSST8 (cabinet, frame, and Torch) NOTE:  It is recommended that all fasteners be  stainless steel. 1. Using the installation template (W122-0401) supplied,  determine the best mounting location for your new Torch.   (refer to your manual for clearances)  Mark all 14 hole  centres on the wall (surface) using the
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        R E HITCH PIN N I A T E E 9 RAIN TABS When shipped, the rain tabs should be at a 90º angle.  Push  the rain tabs down until they are at an approximate 60º angle to  assist rain in running off and out of the unit. RAIN TAB FIGURE 8 DOOR REMOVAL The door is held in place at the bottom by a retainer tab  FIGURE 9 that inserts into a slot in the bottom edge of the door, and  at the top with a tab that secures in the same fashion.  The  door is removed by lifting it off the tabs.  When replacing,  gu
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        10 TFSSO FRAME INSTALLATION 1.  Hang the frame onto the fi rebox by engaging the  FIGURE 13 top trim bracket into the slot in the top of the frame  and the bottom hooks of the frame into the slot in  the mounting cabinet. FIGURE 12 TRIM SLOT BRACKET TRIM BRACKET 2. Install the trim bracket supplied in your manual  baggie to the fi rebox using 3 screws. FRAME (REAR VIEW) DOOR CHAIN NOTE:  If the frame needs to be secured, use two screws  in the holes provided behind the control door. Insert the doo
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        11 ACCENT GLASS INSTALLATION Carefully sprinkle the accent glass onto the glass support  ACCENT evenly.  Ensure no glass falls into the burner area.  If this  GLASS happens, insert a clean bag into your vacuum cleaner and  BURNER vacuum out the accent glass.  Replacement accent glass  can be purchased from your authorized dealer. FIGURE 16 GLASS SUPPORT LK8 LIGHT INSTALLATION (OPTIONAL) 1. Turn off the electrical and gas supply to the appliance. 2. Remove the frame from the unit by removing the 
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        W a K r n E o T c 12 OPERATING INSTRUCTIONS If the appliance keeps shutting off, have it serviced. Keep After extended periods of non-operation such as following  a vacation or a warm weather season, the fi replace may  burner and control compartment clean. When lit for the fi rst time, the fi replace will emit a slight emit a slight odour for a few hours. This is caused by  odour for a few hours. This is a normal temporary dust particles burning off. condition caused by the curing “burn-in” of int
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        13 MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE  CLEANING SERVICING THE APPLIANCE. •  Visually inspect the appliance for carbon buildup. CAUTION: Label all wires prior to disconnection when  •  Using a small whisk or brush, brush off the excess carbon   servicing controls. Wiring errors can cause improper and   and vacuum up or sweep into the garbage. dangerous operation. Verify proper operation after servicing.  This appliance should be inspected before use and at  •  Check the fi re
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        14 REPLACEMENTS Contact your dealer for questions concerning prices and  availability of replacement parts. Normally all parts can be  ! WARNING ordered through your authorized dealer or distributor.  Failure to position the parts in accordance with these diagrams or  When ordering replacement parts always give the following  failure to use only parts specified approved with this appliance may  information: result in property damage or personal injury. 1.  MODEL & SERIAL NUMBER OF APPLIANCE FOR 
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        15 TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT  THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED. SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, Hot and neutral wires are  - Connect the hot wire to the black wire.  Connect the neutral  burner ignites,  reversed at control module. wire to the white wire. electrode continues  to spark for Sensor / fl ame not  - Raise electrode / sensor up into fl ame 1/4” above the burner. complete 7 seco
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        16 W415-0689 / 06.25.08 Fireplace Service History This fireplace must be serviced annually depending on usage SPECIAL CONCERNS DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE