Resumo do conteúdo contido na página número 1 
                    
                        ODSHR Series 
Outdoor Woodburning Fireplace
Homeowner's Installation 
and Operating Manual
Model:
ODSHR42
1384
SHR cover
5/27/99   djt
Underwriter's Laboratories 
Report No. MH20546
DO NOT DISCARD THIS MANUAL:  Retain for future use.
20002264  10/06  Rev. 17                                                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        ODSHR Outdoor Woodburning Fireplace Table of Contents PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation.  Failure to follow  these instructions may result in a possible fire hazard and will void the warranty.  Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  Specifications and Framing Dimensions  . . . . . . . . . . . . . . . . . . . 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        ODSHR  Outdoor Woodburning Fireplace Safety Information NOTE: This unit is intended for outdoor use in the United States using CF11 or SK chimney systems. The unit  may be installed indoors, in the U.S. only, using CF11 chimney system only. This unit is intended for outdoor  use in Canada using the SK chimney system only. Do not obstruct or modify air inlets/outlets in any  Description manner.  Do not install combustible materials on any of the  The ODSHR Series (Super Hearth) fireplace is a clea
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        ODSHR Outdoor Woodburning Fireplace   ODSHR42 Series Woodburning Fireplace Minimum ��"  Rough  (889 mm) ���" Opening  Depth 13���" Dia. 62 ���" (1578 mm) ����� " (340 mm) 264 mm) ����� " (280 mm) 11" Dia. ���" ���" (279 mm) Minimum Rough Opening  Minimum Width 53���" (1365 mm) Rough  Opening  Height ���" 12���" (318 mm) 48���" (1226 mm) 15 ���" (397 mm) 44" Outside �� " Gas Line 42" (1118 mm) Air (610 mm) Access (1067 mm) 13���" �����" (349 mm) (189 mm) 14���" 7���" 52 ���" Gas Line Access (368 
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        ODSHR  Outdoor Woodburning Fireplace Chase Installation Exterior Chase Installation Insulation methods shown are optional for cold climate, not a  requirement for unit operation or exterior installation . Termination Cap Interior Chase  Storm Collar Termination Cap Installation Pan Flashing Storm Collar Pan Flashing Batt Insulation (cut out around  Exterior  firestop) Siding Draftstop Exterior  Siding Firestop Ceiling  Level Interior sides  of chase  Ledge  should be  Bracket weather proof Surrou
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        ODSHR Outdoor Woodburning Fireplace Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY IWF282 SECTION 30˚ Elbow Offsets 30˚  ELBOW IWF282  RETURN ELBOW MBUF  B 1' Offset 1 ¹⁄₂' 3' 4' Rise G A 5/26/96  0  0  0  0  0  3"  11" G 30˚   1  0  0  0  0  8 ¹⁄₄"  20" OFFSET  0  1  0  0  0  11 ¹⁄₄"  25 ¹⁄₄" D ELBOW E  2  0  0  0  0  13 ¹⁄₂"  29 ¹⁄₄" RISE 6 FT.  1  1  0  0  0  16 ¹⁄₂"  34 ¹⁄₄" 11CS  30˚  C  0  0  1  0  0  20 ¹⁄₄"  40 ³⁄₄" SUPPORT RETURN H ELBOW 2  1  0  0  0 
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        ODSHR  Outdoor Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure  The Ten Foot Rule safety and to save time and money. An installer must  predetermine where a fireplace will be set and how the  Major U.S. building codes specify a minimum chimney  chimney system will be run. height above the roof top. The “Ten Foot Rule” is a fire  safety rule and not a draft rule.  To ensure proper draft,  Mounting the Fireplace it is recommended that you always mee
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        ODSHR Outdoor Woodburning Fireplace Chimney Supports Installation The chimney system is supported by the fireplace for  vertical chimney heights less than 30' (9 m) above the   Insulating Fireplace Enclosure  hearth. Chimney supports are required if the vertical  for Cold Climates height exceeds 30' (9 m) with 11CF chimneys. Locate  chimney supports at ceiling holes or other structural  If you live in a cold climate, it is not required but  framing at 30 foot heights. Spacing between chimney  hig
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        ODSHR  Outdoor Woodburning Fireplace Locate center point of the chimney on ceiling as though   Framing a straight up chimney arrangement is to be used.  Mea- Framing can be constructed before or after the fireplace  sure your offset dimension from straight up chimney  is set in place, however, most installers build the frame  center point on ceiling. before setting the fireplace. Ceiling Chimney Hole/ Possible Obstructions Frame fireplace with 2 x 4 lumber or heavier materials.   The size of the ho
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        ODSHR Outdoor Woodburning Fireplace Cutting the Hole 17 ¹⁄₂" Existing  (445 mm) Cover fireplace collar opening and cut proper sized 17 ¹⁄₂" Ceiling  (445 mm) Joists chimney hole in chimney. Chimney  Framing the Ceiling Hole Hole Frame the ceiling chimney hole as shown in Figure  13.  It is good practice to use framing lumber that is the  same size as the ceiling joists; this is a requirement at  attic level. The following table gives firestop spacer model num- bers: New Framing  Members Chimney Ho
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        ODSHR  Outdoor Woodburning Fireplace Positioning, Safety Strips,  Securing the Fireplace Slide fireplace into position. Metal Safety Strips Lift the fireplace front slightly and slide the metal safety  (1, 2 or 3 pieces) strips under front bottom edge about 1 ¹⁄₂" (38 mm),  allowing the remainder to extend in front of firebox.  Overlap strips at least 1/2" (13 mm) to provide a posi- "Z" Safety  Fire- tive joint. (Flat safety strips are packed with fireplace.)   Strip place (Fig. 12)  (not supplied) 
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        ODSHR Outdoor Woodburning Fireplace Installing the Chimney System Inner Pipe  Section Start by attaching the first chimney section to the collar  on top of the fireplace.   Pipe  Rim Hem Install the pipe as pictured in Figure 17.  When  you  get a good lock, you will hear the pipe clearly snap  Lance together. Once sections are snap-locked in place, it is  Pipe  extremely difficult to get them apart.  Make sure the  Rim pipe is firmly snapped and locked together as each  pipe section is mounted. Whe
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        ODSHR  Outdoor Woodburning Fireplace Firestop spacers are not available for, nor are they WARNING:  DO NOT PACK REQUIRED AIR SPACES  required on, vertical walls. WITH INSULATION OR OTHER MATERIALS. The CFM Corporation chimney components have been Mark an outline of the roof hole around the centerpoint  tested and approved with the area where the outer of the nail. NOTE: Hole dimensions given in the chim- pipe slides through the firestop spacer sealed with a ney top installation instructions are h
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        ODSHR Outdoor Woodburning Fireplace   Air Space Clearances Finished Wall Stud Combustible framing material MUST NOT pen- etrate AIR SPACE (shaded areas) Noncombustible  Decorative Fac- ing 2 x 4 Header 2" Must be Sealed  Ledge Bracket with Noncombustible  Standoff Material ³⁄₄" Air Space  to Sides Side View Side View Front View Surround FP1166 Firestop Fig. 21   Fireplace surround flush with finished wall. Stud Wall  ³⁄₄" Air Space  Finished Wall Shield to Back FP1166 surround flush 2 x 4 Finished
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        ODSHR  Outdoor Woodburning Fireplace Mantel Clearance -  No Noncombustible Facing Material Combustible Mantel  12" 12" and Trim Combustible Mantel  (305mm) (305mm) Finished Wall Finished Wall and Trim Max. Max. Header Header 1 ¹⁄₂" 1 ¹⁄₂" Standoff Standoff 12" 12" Noncombustible (305mm) Noncombustible  (305mm) Material Material min. min. Surround  Surround  Face Face 6" * (159mm) Noncombustible Facing  Min. Material Fireplace Opening Fireplace Opening * Minimum width from top of sur- Must be sea
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        ODSHR Outdoor Woodburning Fireplace 40"  Side Wall Protection Min. Adjacent combustible side walls that are within dimen- sions shown in Figure 25 of fireplace opening must  be protected with CFM Corporation Wall Shield Model  SP40 or a specifically built wall shield described in  Figure 26. 40" Min. The special wall shield design described in Figure 26 is  an alternate method of adding protection to side walls  and can be used in place of the SP40 with the same  wall clearances specified for the S
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        ODSHR  Outdoor Woodburning Fireplace Alternate noncombustible materials may be used pro- Seal Cracks Between  Fireplace and Hearth  Noncombustible  viding the (total) thermal resistance (Rt value) of the al- Extension with Non- Decorative Covering  ternate material employed is greater than or equal to R  combustible Material May be Installed  or =  1.09. Thermal resistance (R) or thermal conductivity   .018" Minimum  (K), may be obtained from manufacturer of the material.   Sheet Metal Factors a
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        ODSHR Outdoor Woodburning Fireplace BTU input of a gas appliance installed in fireplace  Wall Covering 2 x 4 Header  should be rated less than 100,000 BTU/Hr. - Do Not Notch at  Noncombustible  Ledge Brackets Decorative Facing Gas pipe installation is intended for connection to a  decorative gas appliance only when (1.) incorporating  Seal All Cracks  Between Fireplace an automatic shutoff device and (2.) complying with the  Surround and Wall  Standard for Decorative Gas Appliances for Installa- 
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        ODSHR  Outdoor Woodburning Fireplace 1 2 3 9a,b 4 8 6 10 7 5 11 13 12 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time,  without notice. ODSHR Outdoor Woodburning Fireplace  Ref. Description Part Number 2264pts  1. Damper Blade 3990185 odshr  2. Damper Handle 20001418  3. Screen Rail 20002262 replacement parts  4. Screen Rod 20002222 1/5/00   djt  5. Screen (two per fireplace) 20002223  6. Screen Pull (t
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        ODSHR Outdoor Woodburning Fireplace Accessories The following accessories for this appliance are available from your local CFM Corporation products distributor.  Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695  Meadowvale Blvd., Mississauga, Ontario, Canada L5N 8A3, Attn:  Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be oper- ated only with CFM Corporation approved