ADT Security Services PremisePro none user manual

User manual for the device ADT Security Services PremisePro none

Device: ADT Security Services PremisePro none
Category: Home Security System
Manufacturer: ADT Security Services
Size: 1.04 MB
Added : 6/16/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADT Security Services PremisePro none. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADT Security Services PremisePro none.

For your convenience

If looking through the ADT Security Services PremisePro none user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADT Security Services PremisePro none on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADT Security Services PremisePro none to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADT Security Services PremisePro none User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADT Security Services PremisePro none but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADT Security Services PremisePro none. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

WARNING: This manual contains information on limitations regarding product use and function and
information on the limitations as to liability of the manufacturer. The entire manual should be carefully read.
User Manual

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Table of Contents System Keypads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Keypad Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Reference Sheets 3 Access Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Con- Equipment Maintenance Facility trols could void your authority to use this equipment. If trouble is experienced with this equipment (PC1616, PC1832, PC1864) for repair or war- This equipment has been tested and found to comply with the limits for a Class B digital de- ranty information, contact the facility indicated below. If the equipment is causing harm to vice, pursuant to Part 15 of th

Summary of the content on the page No. 5

System Keypads LCD5500Z Keypad LCD5501Z Keypad Ready Armed Trouble Armed Trouble Ready PK5500/PK5501 12 3 Stay Away 45 6 Chime 78 9 Reset 0 Bypass # * 1

Summary of the content on the page No. 6

Keypad Display Symbols LCD5501 Fixed Message PK5501 15 5 9 6 9 7 11 14 7 11 10 10 8 1 Clock Digits 1, 2 – These two 7 segment clock digits indicate the hour digits when the local clock is active, and identify the zone when the OPEN or ALARM icons are active. These two digits scroll one zone per second from the lowest zone number to the highest when scrolling through zones. 2: (Colon) – This icon is the hours/minutes divider and will flash once a second when the local clock is active. 3Clock Di

Summary of the content on the page No. 7

Reference Sheets Fill out the following information for future reference and store this guide in a safe place. Access Codes Master Code [40] : _________________________ Code Access Code Code Access Code Code Access Code Code Access Code 01 10 19 28 02 11 20 29 03 12 21 30 04 13 22 31 05 14 23 32 06 15 24 33 (Duress) 07 16 25 34 (Duress) 08 17 26 09 18 27 System Information Enabled?  [F] FIRE  [A] AUXILIARY [P] PANIC The Exit Delay Time is _______ seconds. The Entry Delay Time is _______ se

Summary of the content on the page No. 8

Sensor / Zone Information Sensor Protected Area Sensor Type Sensor Protected Area Sensor Type 01 33 02 34 03 35 04 36 05 37 06 38 07 39 08 40 09 41 10 42 11 43 12 44 13 45 14 46 15 47 16 48 17 49 18 50 19 51 20 52 21 53 22 54 23 55 24 56 25 57 26 58 27 59 28 60 29 61 30 62 31 63 32 64 4

Summary of the content on the page No. 9

About Your Security System Your DSC Security System has been designed to provide you with the greatest possible flexibility and conve- nience. Read this manual carefully and have your installer instruct you on your system's operation and on which features have been implemented in your system. All users of this system should be equally instructed in its use. Fill out the “System Information” page with all of your zone information and access codes and store this manual in a safe place for future r

Summary of the content on the page No. 10

Additional features of the PC1616/PC1832/PC1864 Security System are an Automatic Inhibit (Swinger Shutdown) for Alarm, Tamper and Trouble signals after 3 occurrences in a given set period (see Section 5.6 Option [377] in the Installation Manual). There is also a Programmable Keypad Lockout option (see Section 5.3 Option [012] in the Installation Manual). IMPORTANT NOTICE A security system cannot prevent emergencies. It is only intended to alert you and – if included – your central sta- tion of a

Summary of the content on the page No. 11

Disarming (Turning Off /Unsetting) Enter your access code to disarm anytime the system is armed (i.e. Armed ( ) indicator is on). The keypad will beep if you walk through the entry door. Enter your code within _____ seconds to avoid an alarm condition (please check with your installer to have this time programmed). Disarming Error If your code is invalid, the system will not disarm and a 2-second error tone will sound. If this happens, press and try again. Stay Arming (Partially Turning On /

Summary of the content on the page No. 12

When Alarm Sounds The system can generate 2 different alarm sounds: Continuous Siren = Intrusion (Burglary Alarm) Temporal / Pulsed Siren = Fire Alarm Intrusion (Burglar) Alarm Continuous Siren If you are unsure of the source of the alarm approach with caution ! If the alarm was accidental, enter your Access Code to silence the alarm. Call your central station to avoid a dispatch. Fire Alarm Pulsed Siren Follow your emergency evacuation plan immediately! If the fire alarm was accidental (i.e.

Summary of the content on the page No. 13

4. To unbypass a zone, enter the two-digit number of the zone(s) to be bypassed (01-64). You can also use the keys to find the zone, and then press to select the zone. The “B” will disappear from the dis- play to show that the zone is no longer bypassed. 5. To exit bypassing mode and return to the Ready state, press . Bypassing Zones with a PK5501/LCD5501Z keypad Start with disarming the system 1. Press , then your [access code] (if required). 2. Enter the two-digit number of the zone(s)

Summary of the content on the page No. 14

Trouble Conditions When a trouble condition is detected, the Trouble ( ) or System indicator will turn on, and the keypad will beep every 10 seconds. Press the key to silence the beeps. Press to view the trouble condition. The Trouble ( ) or System indicator will flash. The corresponding trouble will be represented by numbers 1-8. LED/ Trouble Condition Comments Action DIGIT 1 Service Required (1) Low Battery (2) Bell Circuit (3) System Trouble (4) System Tamper (Press [1] for more infor- (5

Summary of the content on the page No. 15

For systems using multiple partitions/areas, access codes can be assigned to specific or multiple partitions/areas. Please contact your alarm company for details. The minimum number of variations of access codes (key) is 27027 when 37, 6-digit user codes are used. For SIA Installations, duplicate or duress codes derived from user codes +/- 1 digit are not allowed. The access codes have programmable attributes which allow zone bypassing, remote access using the ESCORT5580TC or one-time use activ

Summary of the content on the page No. 16

Bell Squawk Attribute This attribute is used to determine whether an access code should generate an arming/disarming Bell Squawk upon entry of the code for Away arming. The Wireless Keys with access codes associated with them may gener- ate Arming/Disarming Bell squawks. If desired, this option may be used with codes that are manually entered. Please contact your installer to have this programmed. NOTE: The Master Code cannot use the Bell Squawk attribute, but is required to enable it for other

Summary of the content on the page No. 17

[2] Auto-arm Control Pressing [2] while in the User Function menu will enable (3 beeps) or disable (one long beep) the Auto-arm fea- ture, by partition. With this feature enabled, the panel will automatically arm in the Away mode (Stay Away zones active) at the same time each day. The auto-arm time is programmed with the [][6][Master Code][3] command. [3] Auto-arm Time The system can be programmed to arm at a programmed time each day, per partition. Up

Summary of the content on the page No. 18

Changing Brightness/Contrast PK5500/LCD5500 keypads When this option is selected, the keypad will allow you to scroll through 10 different brightness/contrast levels. 1.Press [Master code]. 2. Use the keys to scroll to either Brightness Control or Contrast Control. 3. Press to select the setting you want to adjust. 4. a) ‘Brightness Control’: There are multiple backlighting levels. Use the keys to scroll to the desired level. b) ‘Contrast Control’: There are 10 different display contrast le

Summary of the content on the page No. 19

Refer to the following chart: [1] - A, B, C, 1 [6] - P, Q, R, 6 [2] - D, E, F, 2 [7] - S, T, U, 7 [3] - G, H, I, 3 [8] - V, W, X, 8 [4] - J, K, L, 4 [9] - Y, Z, 9,0 [5] - M, N, O, 5 [0] - Space 7. When the required letter or number is displayed use the arrow keys ( ) to scroll to the next letter. 8. When you are finished programming the Zone Label, press the key, scroll to “Save,” then press . 9. Continue from Step 2 until all Labels are programmed. Viewing the Event Buffer from a PK5500/LCD5500

Summary of the content on the page No. 20

Testing Your System NOTE: If you are going to perform a System Test, call your Monitoring Station to inform them when you begin and also when you end the test. Testing Your Keypad Sounder and Siren The System Test provides several system tests, and a two-second check of the keypad sounder and bell or siren. 1.Press [Master Code] . 2. The following will occur: - The system activates all keypad sounders and bells or sirens for two seconds. All keypad lights turn ON. - PK5500/LCD5500 keypads


Alternative user manuals
# User manual Category Download
1 ADT Security Services 3000EN User manual Home Security System 1
2 ADT Security Services D7412 User manual Home Security System 0
3 ADT Security Services 3000 User manual Home Security System 65
4 ADT Security Services Security Manager 2000 User manual Home Security System 0
5 ADT Security Services ADT-UDACT User manual Home Security System 23
6 ADT Security Services Focus 200 Plus User manual Home Security System 1
7 ADT Security Services EZ User manual Home Security System 19
8 ADT Security Services Power 864 User manual Home Security System 21
9 ADT Security Services 8112 User manual Home Security System 21
10 ADT Security Services BHS-4000A User manual Home Security System 5
11 ADT Security Services D9412 User manual Home Security System 19
12 ADT Security Services 6112 User manual Home Security System 3
13 ADT Security Services Security System User manual Home Security System 6
14 ADT Security Services BHS-3000C User manual Home Security System 5
15 ADT Security Services PowerSeries SCW9045-433 User manual Home Security System 49
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9