Friedrich CP14 user manual

User manual for the device Friedrich CP14

Device: Friedrich CP14
Category: Air Conditioner
Manufacturer: Friedrich
Size: 0.81 MB
Added : 8/26/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich CP14. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich CP14.

For your convenience

If looking through the Friedrich CP14 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich CP14 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich CP14 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich CP14 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich CP14 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich CP14. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operating Guide
Compact Programmable
Room Air Conditioner with remote control
CP14
CP18
CP24
Please register
your air conditioner
Whenever you call to request service
on your appliance, you will need to
provide your complete model number
and serial number. You can fi nd this
information on the model and serial
number label.
Please record model and serial
number information below:
MODEL NUMBER
SERIAL NUMBER
PURCHASE DATE
66121417 (1-07)

Summary of the content on the page No. 2

Table of Contents Air Conditioner Safety ......................................................................................................................................................2 Installation Requirements ...............................................................................................................................................3 Tools and Parts ........................................................................................................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fi re, electrical shock or injury when using your air conditioner, follow these basic precautions: ■ Plug into a grounded 3 prong outlet. ■ Do not use an extension cord. ■ Do not remove plug ground prong. ■ Unplug air conditioner before servicing. ■ Do not use a plug adapter. ■ Use two or more people to move and install air conditioner. SAVE THESE INSTRUCTIONS Installation Requirements Location Requirements Tools and Parts Gathe

Summary of the content on the page No. 4

Window installation Electrical Requirements Window opening measurements: 27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A). WARNING 20" min. (50.8 cm) opening height (B). Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove powercord ground prong. A Do not use a plug adapter. B Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. A.27"min.(76.2cm) B . 20" min. (50.8 cm) Ground wire must be connected to

Summary of the content on the page No. 5

RESET RESET TEST TEST Recommended grounding method WARNING This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer's responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical

Summary of the content on the page No. 6

Installation Instructions Unpacking 5. Remove the window lock bracket and screw from the air 6. Remove front panel screw from right side of fi lter conditioner and set aside. area. WARNING Excessive Weight Hazard Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. Remove packaging materials Remove and dispose of or recycle packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a

Summary of the content on the page No. 7

Window Installation (on some models) NOTES: Bottom view ■ Handle air conditioner carefully and gently. ■ Be sure your air conditioner cabinet does not fall out of the opening during installation or removal. ■ The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded A 3prong power outlet. ■ Do not block the louvers on the front panel. B ■ Do not block the louvers on the outside of the air conditioner. A. Curtain housing B. Curtain bottom c

Summary of the content on the page No. 8

Install Cabinet into Window Attach Side Curtains to Window Frame ■ Handle air conditioner carefully and gently. 1. Pull left-hand curtain out until it fits into window channel. Use a ³⁄₃₂" drill bit to drill a starter hole through the hole in the ■ Be sure your air conditioner cabinet does not fall out of the curtain housing and into the lower window sash. opening during installation or removal. ■ The place where the power cord exits the air conditioner Front View should be no more than 4

Summary of the content on the page No. 9

2. Using #10 x ⁷⁄₈" pan-head Phillips screws, attach bracket to cabinet. Repeat for other bracket. Complete Installation 3. Loosen locking nut and turn the adjustment bolt (C) for each 1. Insert seal behind the top of the lower window sash and bracket until the bolt touches the wall (B). against the glass of the upper window (B). 4. Tighten the locking nut on adjustment bolt to lock in position. 2. Place one window-lock bracket on top of lower window and against upper window sash on each sid

Summary of the content on the page No. 10

■ Use 2" x 4" or thicker lumber for wood frame. 2. Insert cabinet into the framed wall opening. The top of the cabinet should extend ³⁄₄" (19.1 mm) into the room. If there is trim, the cabinet should extend ³⁄₄" (19.1 mm) past the trim. A B A B C A. Outside width B. Outside height C. Depth 4. Apply wood preservative to the outside exposed surface. 5. Insert the frame in the wall opening. Square and level frame. A. ³⁄₄ " (19.1 mm) extending into room B. Trim 6. Attach frame securely to the wall

Summary of the content on the page No. 11

3 5.5. UsUsing 1 - #10 x ing 2 - #10 x ³⁄₈" r /8 o" round-head scre und-head screws, att w, attach front of panel ach bottom front of panel to chassis. to chassis. WARNING Electrical Shock Hazard Connect green ground wire to ground screw. Failure to do so can result in death or electrical shock. 3. Connect green ground wire to cabinet base with ground screw. Position ground wire pointing straight up. Put excess ground 6. Reinstall fi lter and replace front grille. wire between coil and air c

Summary of the content on the page No. 12

Starting Your Air Conditioner—Digital Control Temperature Press, or press and hold, the plus button to raise the Money Auto Swing Timer Saver® temperature 1º until it reaches 86ºF (30ºC). 0 F 0 F Temp/Hour Temp/Hour Hr. Hr. POWER High Cool Med Mode Fan Speed Low Fan Only Press, or press and hold, the minus button to lower the temperature 1º until it reaches 64ºF (18ºC). 1. Press POWER to turn on air conditioner. Timer Delay To set the Timer for a 1- to 24-hour delay until the air conditioner tur

Summary of the content on the page No. 13

To raise the temperature: To operate air conditioner with remote control Press the plus button to raise the temperature. Each time you press or hold the plus button, the temperature will go up 1º until it NOTE: Remote control may vary in appearance. reaches 86°F (30°C). To lower the temperature: Press the minus button to lower the temperature. Each time you press or hold the minus button, the temperature will go down 1º until it reaches 64°F (18°C). To set Timer for a 1- to 24-hour delay before

Summary of the content on the page No. 14

Air Conditioner Care Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care Cleaning the Front Panel for your air conditioner properly. Call your local authorized dealer 1. Turn off air conditioner. for an annual checkup. Remember… the cost of this service call 2. Remove the air filter and clean it separately. See “Cleaning is your responsibility. the Air Filter.” 3. Wipe the front panel with a soft, damp cloth. Cleaning th

Summary of the content on the page No. 15

■ There is excessive heat or moisture (open container Air conditioner power supply cord trips (Reset button cooking, showers, etc.) in the room. Use a fan to exhaust pops out) heat or moisture from the room. Try not to use heat- producing appliances during the hottest part of the day. ■ Disturbances in your electrical current can trip (Reset ■ The louvers are blocked. Install the air conditioner in a button will pop out) the power supply cord. Press and location where the louvers are free f

Summary of the content on the page No. 16

Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges fo


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21