Friedrich EQ08 user manual

User manual for the device Friedrich EQ08

Device: Friedrich EQ08
Category: Air Conditioner
Manufacturer: Friedrich
Size: 1.34 MB
Added : 8/26/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich EQ08. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich EQ08.

For your convenience

If looking through the Friedrich EQ08 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich EQ08 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich EQ08 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich EQ08 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich EQ08 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich EQ08. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Power
®
Temperature
Cooler Warmer
Cool
Fan Fan Money
Only Speed Saver
Timer Operation
On/Off Start Stop Set Hr.
Room Air Conditioners
Portable Chassis Models
XQ05, XQ06, XQ08, XQ10, XQ12
EQ08, YQ07
Register your air conditioner
Modelinformationcanbefoundonthenameplate.Itis
located on thefront of theunit, on theleftsidedirectly
below the controls.
To register your room air conditioner, complete and mail
the enclosed registration card or register on-line at www.
friedrich.com (USA only). For your

Summary of the content on the page No. 2

920-197-01 Congratulations! You have purchased the very latest in room air conditioner technology. Your new Friedrich high efficiency room air conditioner will give you many yearsofde- pendable service. Many extra features have been built into your Friedrich air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation. Table of contents Air Conditioner Operation Your Safety and the safety of others.......................

Summary of the content on the page No. 3

920-197-01 WARNING: Before operating your unit Make sure the wiring is adequate for your unit. CIRCUIT RATING REQUIRED WALL OR TIME DELAY If you have fuses, they should be of the time delay type. Before you install RECEPTACLE MODEL FUSE or relocatethisunit,besurethattheamperageratingofthecircuitbreaker AMP VOLT NEMA NO. or time delay fuse does not exceed the amp rating listed in Figure 1. XQ0 XQ06 XQ0 XQ10 DO NOT use an extension cord. 15 125 5-15R XQ12 EQ08 Thecordprovidedwillcarry theproper

Summary of the content on the page No. 4

920-197-01 How to operate your Friedrich room air conditioner (XQ models) To start unit 8 9 2 3 4 1 Figure 3 If your air conditioner is installed and plugged into a proper re cep t a cle, it is ready to go. The first time the unit is started, the compressor will delay for three minutes. See Automatic Component Protection on the following page. PM Touch the Power button once. The unit will automatically be in Cool 1 mode with the temperature set at 75°F (24°C) and the fan speed at F1, the sleep s

Summary of the content on the page No. 5

920-197-01 Howtousetheremotecontrol To start unit To set the timer NOTE: You can set the START and STOP times a minimum of one hour 1 POWER - Press the Power button once. The unit will automatically apart, and a maximum of 23 hours apart. start in the mode and fan speed it was last left on. 9 TIMER START - Press Start to view the current start time for cooling. Tosetmodeofoperation Continue pressing the Start button until you arrive at the start time youdesire. Thestarttimeforcoolingwillthenbese

Summary of the content on the page No. 6

920-197-01 Care and maintenance To remove filter Simply turn the unit off and pull the filter frame up and towards you (See Figure 6). Clean with warm water and a mild detergent, rinse, dry, and replace by sliding the filter back into position behind the front panel. Figure 6 Installation instructions ® NOTE: This section includes installation instructions for window mount and thru-the-wall mount methods. TwinTemp heat/cool units are designed for permanent thru-the-wall installation. Mounting th

Summary of the content on the page No. 7

920-197-01 Sash window installations Figure B WARNING Falling Object Hazard CURTAIN ASSEMBLY Not following Installation Instructions RETAINING for mounting your air conditioner can BRACKET SHELL SUPPORT result in property damage, injury, or CHANNEL death. STEP 1 After removing the unit from shipping carton, remove tape holding decorative front in place. Lay front in a safe out-of-the-way place, then CURTAIN slide chassis out of cabinet (see Figure A). ASSEMBLY (LEFT) STEP 2 Attach curtain a

Summary of the content on the page No. 8

920-197-01 STEP 6 Inspect the unit before inserting it into the sleeve. The fan and blower wheel should be manually rotated to insure that they turn Figure D freely. Be sure the electrical cord will be out of the way when inserting the unit into the sleeve. GRAY FOAM NOTE: For your safety, DO NOT plug the electrical cord into an GASKET electrical outlet until installation is complete. (see illustration, item #5 on page 6) STEP 7 If the unit checks out OK, it is ready to be placed into po

Summary of the content on the page No. 9

920-197-01 Thru-the-wall installations WARNING Falling Object Hazard Not following Installation Instructions for mounting your air conditioner can result in property damage, injury, or death. STEP 1 After removing the unit from shipping carton, remove tape holding STEP 5 Position the front edge to extend into the room 3/4" minimum at decorative front in place. Lay front in a safe out-of-the-way place, top of cabinet and 1" minimum at bottom (see Figure G). then slide chassis out of cabinet (s

Summary of the content on the page No. 10

920-197-01 STEP 7 Cut two pieces of standard 1" lumber (supplied by installer) to the STEP 9 Complete the installation by following STEPS 6 through 10 of Sash length and width required. Place in front and back of bottom sill chan- Window Instructions (Page 8). Window Seal Gasket mentioned nel as shown in Figure G. Secure with nails (supplied by installer). in STEP 8 will not be required. STEP 8 Seal all holes in the cabinet with caulking compound (supplied IMPORTANT: Before operating your unit,

Summary of the content on the page No. 11

920-197-01 Troubleshooting tips Power failure Noises If you have a power failure, the unit's auto-restart feature will resume operation All air conditioners make some noise. We build them to operate as quietly as in the selected mode prior to the power failure. possible. An air con di t ione r mounted in a wall is quieter than one mounted in a window. It is important to ensure that the chassis seal gasket is properly installed (refer to Installation Instructions, Step 8, page 8). Won't cool? If

Summary of the content on the page No. 12

920-197-01 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charg

Summary of the content on the page No. 13

Power ® Temperature Cooler Warmer Cool Fan Fan Money Only Speed Saver Timer Operation On/Off Start Stop Set Hr. Unidades de aire acondicionado de tipoventana Modelos de chasis portátil XQ05, XQ06, XQ08, XQ10, XQ12 EQ08, YQ07 Registre su unidad de aire acondicionado La información del modelo aparece en la placa de la partefrontaldelaunidad,enelladoizquierdo,justo debajo de los mandos. Porfavorcompleteyenvíelatarjetaderegistroque viene con el producto, o regístrese en línea en www. friedrich.com

Summary of the content on the page No. 14

920-197-01 ¡Enhorabuena! Acaba de comprar la tecnología más avanzada en unidades de aire acondicionado de tipo ventana. Su unidad de aire acondicionado de tipo ventana Friedrich le dará muchos años de servicio de confi anza. Este modelo de Friedrich incorpora muchas características para garantizar el funcionamiento silencioso, la mejor circulación posible del aire frío, aire seco, controles funcionales y un funcionamiento económico. Contenido Funcionamiento del aire acondicionado Su segurida

Summary of the content on the page No. 15

920-197-01 ADVERTENCIA: Antes de utilizar la unidad Asegúrese de que los cables sean apropiados. CIRCUITO ENCHUFE Si tienen fusible, deben ser de relevo. Antes de instalar o mover la unidad de O FUSIBLE DE PARED MODELO DE RELEVO: sitio, asegúrese de que los amperios del interruptor automático y del fusible de relevo no excedan el máximo de amperios indicados en la fi gura 1. AMP VOLT NÚM. NEMA XQ05 • XQ06 NO utilice un cable de extensión. XQ08 • XQ10 15 125 5-15R El cable que se suministra tran

Summary of the content on the page No. 16

920-197-01 Funcionamiento del aire acondicionado Friedrich (Modelos XQ) Puesta en marcha Si el aire está instalado y enchufado en el enchufe correcto, está listo para 8 9 2 3 4 1 Figura 3 ponerse en marcha. La primera vez que utilice la unidad, el compresor tardará tres minutos en ponerse en marcha. Consulte la sección de “Protección automática de los componentes” en la página siguiente. PM Pulse una vez el botón Power (Encendido). La unidad se enciende 1 automáticamente en COOL a una temper

Summary of the content on the page No. 17

920-197-01 Cómo utilizar el mando a distancia Puesta en marcha TIMER START - Pulse Start para ver a qué hora debe empezar a 9 enfriar. Siga pulsando hasta que aparezca en la pantalla la hora en 1 POWER - Pulse una vez el botón Power. La unidad se encenderá la que quiere que se encienda. Así se indica a qué hora quiere que automáticamente con el modo y velocidad del ventilador en que estaba cuando se apagó. comience enfriar. TIMER STOP - Pulse el botón Stop y siga pulsando hasta que la hora

Summary of the content on the page No. 18

920-197-01 Cuidado y mantenimiento Cómo quitar el filtro Apague la unidad y saque el fi ltro estirando hacia arriba y hacia usted (véase la fi gura 6). Límpielo con agua caliente y un detergente suave, enjuáguelo y séquelo y vuelva a ponerlo en su sitio detrás del panel frontal. Figura 6 Instrucciones de instalación NOTA: Este manual incluye instrucciones de instalación para montarlo en ventanas o en la pared. Los modelos TwinTemp® de aire frío/aire caliente son de insta- lación de pared. Para m

Summary of the content on the page No. 19

920-197-01 Instalación de ventana Figure B ADVERTENCIA BARRA DE Peligro de caída de objetos SUJECIÓN DEL ACOPLE No seguir las instrucciones de DE LA instalación para montar su aire CANAL DE APOYO DEL PERSIANA acondicionado puede ocasionar ESTANTE daños a la propiedad, lesiones físicas o la muerte. PASO 1 Cuando saque la unidad de la caja de embalaje, quite la cinta adhesiva que sujeta la parte frontal. Deje la parte frontal en un ACOPLE sitio seguro y deslice el chasis de la caja (vé

Summary of the content on the page No. 20

920-197-01 PASO 6 Inspeccione la unidad antes de meterla en la funda. Debe rotar manualmente el ventilador y la rueda del extractor para asegu- Figura D rarse de que no estén obstruidas. Asegúrese de apartar el cable al meter la unidad en la funda. JUNTA SELLADORA NOTA: Por motivos de seguridad, NO enchufe el cable hasta que DE ESPUMA GRIS termine de instalar la unidad. (Véase la ilustración del artículo 5 de la página 18) PASO 7 Si la unidad se ve bien, puede ponerla en su sitio en


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21