Friedrich SH15 user manual

User manual for the device Friedrich SH15

Device: Friedrich SH15
Category: Air Conditioner
Manufacturer: Friedrich
Size: 2.63 MB
Added : 8/26/2013
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich SH15. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich SH15.

For your convenience

If looking through the Friedrich SH15 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich SH15 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich SH15 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich SH15 User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich SH15 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich SH15. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Hazardous Duty Room
Air Conditioner
|
230-Volt: SH15 SH20
920-024-07 (8/09)
Power
Temperature
Installation & Operation Manual

Summary of the content on the page No. 2

Table of Contents Operation and Care Instructions Your Safety and the safety of others................................................................................................................................... 3 General Instructions............................................................................................................................................................ 3 Filter information...................................................................................

Summary of the content on the page No. 3

Congratulations! Thank you for your decision to purchase the Friedrich Hazardgard (Hazardous Duty Room Air Conditioner). Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable, efficient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit to assure quiet operation, the greatest circulation of cool, dry air, and the most economic operation. General Instructions This Installation

Summary of the content on the page No. 4

Filter Information A clogged, dirty!lter reduces the air"ow through the unit and The!lter in your Friedrich removes dust, pollen and other reduces its ef!ciency. You should check the!lter every seven impurities from the air as they are drawn through the unit. to ten days, depending on the amount your unit is used. Clean The!lter is permanent and reusable, and has a germicidal the!lter regularly. treatment which is not affected by washing. FILTER RETAINER CLIPS The lter can be removed for cleanin

Summary of the content on the page No. 5

Hazardgard Special Features Permanent Split-Capacitor, totally enclosed fan motor to Copper tubing/aluminum!n coils. assure ef!cient operation even under adverse electrical Galvanized steel cabinet and base pan, all bonderized. conditions. Motor has a special stainless steel shaft to resist Slide-out chassis for easy installation in window or corrosion and a hermetically sealed overload for arc-free through–the–wall. operation. Extra insulation inside, including completely insulated High capacit

Summary of the content on the page No. 6

Installation Instructions Models SH15 and SH20 NOTE: THIS MANUAL INCLUDES INSTALLATION INSTRUCTIONS FOR BOTH WINDOW MOUNT AND THROUGH- THE-WALL INSTALLATIONS WARNING Explosion Hazard Electrical Shock Hazard Electrically connect unit in accordance with NEC Code Article 501. Failure to do so can result in re, or electrical shock. Electrical Requirements ALL FIELD WIRING MUST MEET THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 70) ARTICLE 501. THE FIELD-PROVIDED CIRCUIT PROTECTION

Summary of the content on the page No. 7

Window Mount Installation Hardware ITEM DESCRIPTION QTY. No. SHELL MOUNTING PARTS 1 SUPPORT BRACKET 2 2 SCREW, 10 - 24 x 1" HEX HEAD 4 3 10 - 24 FLAT WELDNUT 4 4 SCREW, SHEET METAL #12A x 2" 7 WINGBOARD ANGLE MOUNTING 5 WINGBOARD ANGLE, TOP 1 6 WINGBOARD ANGLE, SIDE 2 7 SCREW, SHEET METAL #8A x 3/8" 2 WINGBOARD MOUNTING PARTS 8 WINGBOARD (MASONITE) - (NOT SHOWN) 1 ITEM # 3 ITEM # 2 9 "J" TYPE SPEED NUT 4 10 WINGBOARD CLIP (SPRING STEEL) 4 11 SCREW. #8A x 1/2" PHILLIPS TRUSS HD. 4 WINDOW SEALIN

Summary of the content on the page No. 8

UnpackingTheUnit STEP1 Remove decorative plastic return air grille to a safe area away from the unit. STEP2 Remove the installation hardware, wingboard and two (one light colored and one dark colored) gaskets from beneath the unit, and place them in a safe area away from the unit. STEP3 Remove the chassis retainer by removing the far right screw in the basepan (see Figure A); save this screw to reattach the chassis retainer after installatio. Also, remove and discard the two retainer screws and

Summary of the content on the page No. 9

Shell(Cabinet)Preparation each end of the top angle (Item #5) with the top loops of the side It will be necessary to relocate the sill plate of the cabinet 2" angle. Install two (2) screws (Item #7) to secure the top angle back from its shipping position, and the shell guides 4" forward, tabs and the side angle to the rear-most holes in the side of the to the forward-most hole in the shell rail. Discard the chassis cabinet (See Figure B, below). retainer wire disconnected in Section II, Step 3.

Summary of the content on the page No. 10

ShellInstallation:SashWindowInstallations WARNING Falling Object Hazard Not following Installation Instructions for mounting your air conditioner can result in property damage, injury, or death. STEP1 Check the window sill and frame to be sure they are in good condition and "rmly anchored to the wall. Repair if necessary. STEP2 CABINET MOUNTING: Raise the lower window sash 1/4" more than the height of the cabinet. Carefully slide the cabinet through the open window until the sill plate channe

Summary of the content on the page No. 11

NOTICE Shell Installation: Thick Wall Instructions for mounting sleeve with slope must be obser- The illustrations below show a standard frame construction ved to prevent entry of water into room. installation as well as some suggested ways of adapting the Failure to follow instructions can result in property damage. support bracket to thick walls and large brick ledges. Typical Installation Sill Plate Figure1 Figure2 10 - 24 SCREW 10 - 24 FLAT NUT 3/8" (10 MM) SLOPE DOWN 3/8" (10 MM) SLOPE

Summary of the content on the page No. 12

"J" TYPE SPEED NUT (ITEM #9) 2 REQUIRED FigureG SPRING STEEL CLIP (ITEM #10) 2 REQUIRED CUT WINGBOARD PANEL CUT EDGE SLIDE CLIP OVER CUT EDGE OF WINGBOARD PANEL CENTER THE HOLE IN THE SPEED NUT OVER THE SLOT IN THE WINGBOARD PANEL STEP5 ASSEMBLE CLIPS TO WINGBOARD PANELS: Assemble "J" type speed nuts (Item #9) and spring steel clips (Item #10) to the edges of the cut wingboard panels (See Figure G). TOP OF CABINET Figure H PLACE WINGBOARD PANEL IN WINDOW JAM TO COMPRESS THE SPRINGS INSIDE THE

Summary of the content on the page No. 13

ShellInstallation:Through-the-wallInstallations WARNING Falling Object Hazard Not following Installation Instructions for mounting your air conditioner can result in property damage, injury, or death. WallPreparation The maximum wall thickness permissible without special construction is determined by the model size to be installed. THE OUT- SIDE CABINET CONDENSER AIR INTAKE LOUVERS MUST NOT BE BLOCKED BY EXTENDING INSIDE THE WALL AREA. Observe the maximum wall thickness shown as dimension "A"

Summary of the content on the page No. 14

Figure L FRAME WALL CONSTRUCTION CAULK ALL SIDES WEATHER CABINET SHIM THE VOID SPACE AT THE TOP AND SIDES WITH WOOD AS REQUIRED Figure M BRICK VENEER WEATHER CABINET CONSTRUCTION CAULK ALL SIDES SHIM VOID SPACES AT TOP AND SIDES WITH WOOD AS REQUIRED Figure N SOLID MASONRY CONSTRUCTION CAULK ALL SIDES CABINET MORTAR 14

Summary of the content on the page No. 15

STEP3 Slide the cabinet into the hole far enough to allow the guide-channel of the sill plate to contact the inside wall surface (See Figure O). STEP4 Drill three (3) 5/32" diameter pilot holes through holes in sill-plate into the framing and install three (3) #12 x 2" long screws (Item #4) (See Figure O). NOTICE Instructions for mounting sleeve with slope must be observed to prevent entry of water into room. Potential property damage can occur if instructions are not followed. Figure O TYPI

Summary of the content on the page No. 16

Chassis Installation STEP 1 Slide the chassis into the cabinet stopping approximately 3" from full insertion. Stuff the chassis seal gasket (Item #14) one inch deep between the chassis and the cabinet (See Figure P). Begin at either bottom corner and go up the side, across the top, and down the opposite side. Make sure that the gasket is behind the conduit connector (furthest from you). Push the chassis into the shell the remaining distance so that the plastic front shrouds the front edge o

Summary of the content on the page No. 17

STEP2 Be sure that the!lter is in place then install the return air grille (See Figure Q). The top of the return air grille can be butted against the bottom of the discharge plenum. Snap the grille into place by pushing the grille up and onto the unit's latches at the bottom. (See Detail 4). Figure Q Discharge Air Plenum DETAIL 2 Slot Tab Return Air Grille Slot Tab DETAIL 1 DETAIL 1 Latches DETAIL 3 Latch Return air grille DETAIL 4 Side view (Cutaway) STEP3 You have completed your installation.

Summary of the content on the page No. 18

Friedrich Air Conditioning Company 10001 Reunion Place, Suite 500 San Antonio, Tx 78216 1-800-541-6645 www.friedrich.com ® HAZARDGARD ROOM AIR CONDITIONERS LIMITED WARRANTY LIMITED ONE YEAR PARTS WARRANTY 1. Limited warranty – One year. Friedrich warrants that it will provide a replacement for any part of this HazardGard Room Air Conditioner found defective in material or workmanship for a period of one (1) year from the date of original purchase. 2. Limited warranty – One year. The Friedr

Summary of the content on the page No. 19

Unidades de aire acondicionado | 230-Volt: SH15 SH20 920-024-07 (8/09) Power Temperature Instrucciones de Instalacion y Funcionamiento

Summary of the content on the page No. 20

Tabla De Contenidos Instrucciones Para Uso Y Mantenimiento Instrucciones generales ....................................................................................................................................................................... 21 Información sobre el ! ltro .................................................................................................................................................................. 22 Lista de control para el mantenimiento .............


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21