Friedrich XQ06M10 user manual

User manual for the device Friedrich XQ06M10

Device: Friedrich XQ06M10
Category: Air Conditioner
Manufacturer: Friedrich
Size: 2.77 MB
Added : 4/17/2014
Number of pages: 47
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich XQ06M10. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich XQ06M10.

For your convenience

If looking through the Friedrich XQ06M10 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich XQ06M10 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich XQ06M10 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich XQ06M10 User manual - Online PDF
Advertisement
« Page 1 of 47 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich XQ06M10 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich XQ06M10. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Temperature
Cooler Warmer
Cool Power
Fan Fan Money
®
Only Speed Saver
Timer Operation
On/ Start Stop Set Hr.
2 0 11
Room Air Conditioners
R-410A Models
Cool Only

115-Volt: XQ05M10 , XQ06M10 , XQ08M10 , XQ10M10

* * * *
Cool with Electric Heat
115-Volt: EQ08M11
*
X-Star-ServMan (1-11) Last character may vary.
*
Service Manual

Summary of the content on the page No. 2

Table Of Contents Important Safety Information .......................................................................................................................................... 2-4 Unit Identifi cation ............................................................................................................................................................... 5 Performance Data .............................................................................................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION The information contained in this manual is intended for use by a qualifi ed service technician who is familiar with the safety procedures required for installation and repair, and who is equipped with the proper tools and test instruments required to service this product. Installation or repairs made by unqualifi ed persons can result in subjecting the unqualifi ed person making such repairs as well as the persons being served by the equipm

Summary of the content on the page No. 4

• Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, and sleeve on the room side of the air conditioning unit while cleaning. • Electrical component malfunction caused by water could result in electric shock or other electrically unsafe conditions when the power is restored and the unit is turned on, even after the exterior is dry. • Never operate the A/C unit with wet hands. • Use air conditioner on a single dedicated circuit within th

Summary of the content on the page No. 5

PROPERTY DAMAGE HAZARDS FIRE DAMAGE HAZARDS: • Read the Installation/Operation Manual for this air conditioning unit prior to operating. • Use air conditioner on a single dedicated circuit within the specifi ed amperage rating. • Connect to a properly grounded outlet only. • Do not remove ground prong of plug. • Do not cut or modify the power supply cord. • Do not use extension cords with the unit. • Failure to follow these instructions can result in fi re and minor to serious property damage. WA

Summary of the content on the page No. 6

UNIT IDENTIFICATION Model Number Code X Q 08 M 1 0 A - A 9th Digit – Engineering Suffi x Indicates Modifi cation (Subject to change) 1st Digit – Function 8th Digit – Marketing Suffi x E = Electric Heat Indicates Modifi cation X = Straight Cool (Subject to change) 7th Digit – Options 0 = Straight Cool 1 = 1 KW Heat Strip, Nominal 2nd Digit Q = Chassis Size 6th Digit – Voltage 1 = 115 Volts 5th Digit - Model Series / Year Introduced 3rd and 4th Digit - Approximate M=2010 BTU/HR

Summary of the content on the page No. 7

PERFORMANCE DATA * R-410A EVAP. AIR TEMP. DEG. F OPERATING PRESSURES ELECTRICAL RATINGS BREAKER FUSE REF. COOLING CONDENSER Discharge Temp Suction Temp Super Heat Sub-Cooling Voltage PERFORMANCE DATA** TEMPERATURE DEG. F Temp. Locked Rotor Charge in Discharge Air Suction Discharge Amps Cool Amps Heat 60 Hertz Amps Drop F. Amps OZ. XQ05M10 57 23 117 133 60 5 19 157 410 4.5 24.0 27.0 115 15 * XQ06M10 54 26 120 152 63 12 18 150 410 4.9 25.0 21.0 115 15 * XQ08M10 51 29 119 160 63 13 25 138 420 6

Summary of the content on the page No. 8

ELECTRICAL DATA WARNING ELECTRIC SHOCK HAZARD Turn off electric power before service or installation. All electrical connections and wiring MUST be installed by a qualifi ed electrician and conform to the National Electrical Code and all local codes which have jurisdiction. Failure to do so can result in personal injury or death. NOTICE FIRE HAZARD Not following the above WARNING could result in fi re or electically unsafe conditions which could cause moderate or serious property damage. R

Summary of the content on the page No. 9

WARNING ELECTRICAL SHOCK HAZARD Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician. Do not use plug adapters. Do not use an extension cord. Do not remove ground prong. Always plug into a grounded 3 prong outlet. Failure to follow these instructions can result in electrical shock, serious injury or death. 8

Summary of the content on the page No. 10

How to operate the Friedrich room air conditioner (XQ models) To start unit Figure5 8 9 2 3 4 1 8 9 2 3 4 1 If your air conditioner is installed and plugged into a proper rec epta c le, it is Figure 3 ready to go. The first time the unit is started, the compressor will delay for three minutes. See Automatic Component Protection on the following page. PM Touch thePower button once. The unit will automatically be inCool X Star 1 PM mode with the temperature set at 75°F (24°C) and the fan speed at

Summary of the content on the page No. 11

How to use the remote control (XQ models) To start unit To set the timer NOTE: You can set the START and STOP times a minimum of one hour POWER - Press thePower button once. The unit will automatically 1 apart, and a maximum of 23 hours apart. start in the mode and fan speed it was last left on. TIMERSTART - PressStart to view the current start time for cooling. 9 Continue pressing theStart button until you arrive at the start time To set mode of operation you desire. The start time for cooling

Summary of the content on the page No. 12

ELECTRONIC CONTROL SEQUENCE OF OPERATION MODE CONTROL FAN ONLY MODE The mode control pad(s) allow the selection of the operating When in the FAN ONLY mode, the compressor will not modes of the unit. operate. The fan will run continuously at the user-selected speed (see “Fan Speed Set” below). Smart Fan is not There is a two second delay before the mode activates its available in FAN ONLY Mode. appropriate relay. FAN SPEED SET OPERATING SEQUENCE / CHARACTERISTICS XQ fan speed is changed by p

Summary of the content on the page No. 13

FUNCTIONAL COMPONENT DEFINITIONS MECHANICAL COMPONENTS Plenum assembly Diffuser with directional louvers used to direct the conditioned airfl ow. Blower wheel Attaches to the indoor side of the fan motor shaft and is used for distributing unconditioned, room side air though the heat exchanger and delivering conditioned air into the room. Slinger fan blade Attaches to the outdoor side of the fan motor shaft and is used to move outside air through the condenser coil, while slinging condens

Summary of the content on the page No. 14

COMPONENTS TESTING TESTING THE ELECTRONIC CONTROL ERROR CODE LISTINGS BOARDS FOR XQ MODELS E1 SHORT CYCLE SITUATION: Defi ned as (compressor powered on before the three minute time delay ten times in one hour. Investigate and correct short cycling problem. X Star PM E2 KEYBOARD STUCK ERROR: If key button(s) are pressed continuously for twenty seconds or more. If MODE Power key is stuck, unit will default to cool. Exit Error Code Cool Mode to see if error “E2” is no longer displayed

Summary of the content on the page No. 15

COMPONENTS TESTING (Continued) EQ08 SYSTEM CONTROL SWITCH - TEST 4. Turn thermostat knob counterclockwise to its warmest position. “EQ08” SYSTEM CONTROL SWITCH – TEST 5. Test for continuity - contacts should be open. Turn knob to phase of switch to be tested. There must be NOTE: The thermostat must be within the temperature continuity as follows: range listed to open and close. 1. “Fan Only” Position – between terminals “MS” and “H” To maintain the comfort level desired, a cross ambient

Summary of the content on the page No. 16

COMPONENTS TESTING (Continued) FAN MOTOR A single phase permanent split capacitor motor is used to drive Many motor capacitors are internally fused. Shorting the the evaporator blower and condenser fan. A self-resetting terminals will blow the fuse, ruining the capacitor. A 20,000 overload is located inside the motor to protect against high ohm 2 watt resistor can be used to discharge capacitors temperature and high amperage conditions. (See Figure 23) safely. Remove wires from capacitor and

Summary of the content on the page No. 17

COMPONENTS TESTING (Continued) HEATING ELEMENT (See Figure) DRAIN PAN VALVE All electric heat models are equipped with a heating element. During the cooling mode of operation, condensate which The EQ08 has a 1.15 KW element. collects in the drain pan is picked up by the condenser fan blade and sprayed onto the condenser coil. This assists in cooling the refrigerant plus evaporating the water. Figure Heating Element During the heating mode of operation, it is necessary that water be re

Summary of the content on the page No. 18

REFRIGERATION SEQUENCE OF OPERATION A good understanding of the basic operation of the The refrigerant leaves the condenser Coil through the liquid refrigeration system is essential for the service technician. line as a warm high pressure liquid. It next will pass through Without this understanding, accurate troubleshooting of the refrigerant drier (if so equipped). It is the function of the refrigeration system problems will be more diffi cult and time drier to trap any moisture present in

Summary of the content on the page No. 19

R-410A SEALED SYSTEM REPAIR CONSIDERATIONS WARNING Refrigeration system under high pressure Do not puncture, heat, expose to fl ame or incinerate. Only certifi ed refrigeration technicians should service this equipment. R410A systems operate at higher pressures than R22 equipment. Appropriate safe service and handling practicces must be used. Only use gauge sets designed for use with R410A. Do not use standard R22 gauge sets. The following is a list of important considerations when working wit

Summary of the content on the page No. 20

R-410A SEALED REFRIGERATION SYSTEM REPAIRS IMPORTANT SEALED SYSTEM REPAIRS TO COOL-ONLY MODELS REQUIRE THE INSTALLATION OF A LIQUID LINE DRIER. EQUIPMENT REQUIRED: 9. High Pressure Gauge - (0 to 750 lbs.) 1. Voltmeter 10. Low Pressure Gauge - (-30 to 200 lbs.) 2. Ammeter 11. Vacuum Gauge - (0 - 1000 microns) 3. Ohmmeter 12. Facilities for fl owing nitrogen through refrigeration tubing 4. E.P.A. Approved Refrigerant Recovery System during all brazing processes. 5. Vacuum Pump (capa


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21