FieldServer FS-RA-CLX-BAS user manual

User manual for the device FieldServer FS-RA-CLX-BAS

Device: FieldServer FS-RA-CLX-BAS
Category: Server
Manufacturer: FieldServer
Size: 1.44 MB
Added : 11/5/2013
Number of pages: 34
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FieldServer FS-RA-CLX-BAS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FieldServer FS-RA-CLX-BAS.

For your convenience

If looking through the FieldServer FS-RA-CLX-BAS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FieldServer FS-RA-CLX-BAS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FieldServer FS-RA-CLX-BAS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FieldServer FS-RA-CLX-BAS User manual - Online PDF
Advertisement
« Page 1 of 34 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FieldServer FS-RA-CLX-BAS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FieldServer FS-RA-CLX-BAS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



FieldServer Technologies
A Sierra Monitor Corporation Company
1991 Tarob Court, Milpitas, California 95035 USA
Phone: (408) 262-2299
Toll Free: (888) 509-1970
Fax: (408) 262-2296
Email: support@fieldserver.com
Web Site: www.fieldserver.com



SlotServer Instruction Manual









APPLICABILITY & EFFECTIVITY


This manual provides instructions for the following FieldServer products:

Description
FS-RA-CLX-BAS
FS-RA-CLX-FIR
FS-RA-CLX-PRO

The instructions a

Summary of the content on the page No. 2

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Table of Contents TABLE OF CONTENTS 1. INTRODUCTION............................................................................................................. 4 1.1. About this product...................................................................................................... 4 2. PRE-STARTUP CHECKLIST.......................................................................................... 5 2.1. Accessories supplied with the

Summary of the content on the page No. 3

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Table of Contents Appendix A.4. Dealing with ControlLogix RPI Settings........................................................26 Appendix A.5. Installing SlotServer on a Remote Rack using CNB Cards...........................27 Appendix A.5.1. Hardware and Software requirements....................................................27 Appendix A.5.2. Setup .........................................................................................

Summary of the content on the page No. 4

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 4 of 34 1. Introduction 1.1. About this product The SlotServer Instruction Manual provides the information necessary to configure the SlotServer, allowing an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and other third party communications protocols supported by the SlotServer. The SlotServer uses implicit communications between the CPU and the SlotServer and is consequently treated as an I/O Se

Summary of the content on the page No. 5

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 5 of 34 2. Pre-Startup checklist 2.1. Accessories supplied with the SlotServer Please verify that the following components were supplied with the SlotServer module: FieldServer Technologies Description PART # 2-way combi-comb connector for LonWorks port Software CD CAT-5 Direct Ethernet Cable Documentation Binder 2.2. Third party components (not supplied by FieldServer Technologies) The following components will nee

Summary of the content on the page No. 6

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 6 of 34 3. Steps for implementation of a SlotServer Project 3.1. Read the SlotServer Instruction Manual This provides guidelines for getting started with the SlotServer, and is very useful for first time implementation of a SlotServer application. 3.2. Install the SlotServer in a ControlLogix Rack. Refer to Section 4 for information on installation. 3.3. Write the SlotServer configuration. • Refer to the FieldServer configurati

Summary of the content on the page No. 7

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 7 of 34 4. SlotServer Installation The SlotServer plugs directly into the AB1756 ControlLogix rack. Take note of the slot number used for the SlotServer as this will be needed when configuring the I/O in the RSLogix software. 4.1. SlotServer Ports and Displays Note that there are several hardware ports available on the SlotServer card, but that this SlotServer model only makes use of a select few. The ports and displays of i

Summary of the content on the page No. 8

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 8 of 34 Communications Status LED’s LonSvc Run Node Off Conf Err Sys Err Com Err 10/100 Act Rx Tx LED Description When the SlotServer is powered up, this light will start flashing after approximately 2 Run minutes. If this light does not flash, it is an indication that the firmware is not running, and that the SlotServer will not be operating. This light will flash when the card’s Neuron chip is unconfigured, and will extingu

Summary of the content on the page No. 9

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 9 of 34 TP/FT10 LonWorks connection This two wire connection is polarity insensitive and can be multi-dropped into a LonWorks Network. Ethernet Port The Ethernet port can be used for configuration and troubleshooting, as well as for Protocols that require an Ethernet connection. Use standard Ethernet cables for this connection. RS-485 Port This is a standard 2-wire RS-485 port. Specify as R1 in the configuration. 4.2.

Summary of the content on the page No. 10

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 10 of 34 5. SlotServer Topology The SlotServer connection varies based on the protocol being used. Refer to the appropriate driver supplement for more details. The diagram in section 4.1 shows the ports available on the SlotServer for each of the protocols. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 ema

Summary of the content on the page No. 11

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 11 of 34 6. Configuring the CPU interface to the SlotServer 6.1. CPU interface Description The SlotServer Data Images (Data Arrays) share data with the ControlLogix CPU tags using the backplane for communication and the FieldServer Logix driver. To map the Logix Driver, the Driver needs to be configured in the SlotServer Configuration. The information that follows details the configuration parameters that can be used for this

Summary of the content on the page No. 12

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 12 of 34 Example // Data Arrays Data_Arrays Data_Array_Name, Data_Array_Format, Data_Array_Length In_1, Float, 76 In_2, Float, 76 Out_1, Float, 76 Out_2, Float, 76 6.4. Server Side Connection Descriptors Section Title Connections Column Title Function Legal Values Adapter Adapter Name ControlNet Example // Server Side Connections Connections Adapter ControlNet 6.5. Server Side Node Des

Summary of the content on the page No. 13

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 13 of 34 6.6. Server Side Map Descriptors 6.6.1. SlotServer Specific Map Descriptor Parameters Column Title Function Legal Values Name of this Map Up to 32 alphanumeric Map_Descriptor_Name Descriptor characters Rate at which IO image Use twice the rate used in Scan_Interval data is updated RSLogix e.g. 0.2s WRBC - to write into Input Image Data buffer Function of Server Map Function Descriptor RDBC - to read from Output

Summary of the content on the page No. 14

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 14 of 34 6.6.3. Map Descriptors Example Only two Map Descriptors are allowed, one to transfer data to the Logix CPU and one to accept data from the Logix CPU. // Server Side Map Descriptors Map_Descriptors 4 Map_Descriptor_Name, Scan_Interval, Function, Node_Name, IO_Data_Type, DA_Name_Start , DA_Count, Protocol_Type_ID Input_BP_Image, 0.2s, WRBC, SlotServer_CPU, REAL, In_1, 2, 0 Output_BP_Image, 0.2s,

Summary of the content on the page No. 15

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 15 of 34 7. Programming the ControlLogix CPU for a small SlotServer Interface The discussion that follows describes the basic steps to set up and test the system for transferring data between CPU tags and the SlotServer using the I/O image method. The quick rd Start example uses LonWorks as the example 3 Party Protocol. A hardcoded template is filled with Lon variables is created. Each item uses a different amount of bytes and

Summary of the content on the page No. 16

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 16 of 34 7.2. Step 2: Add and configure the SlotServer as an IO Module • Right-click on I/O Configuration and select “New Module”. • Choose the 1756-MODULE Choose the 1756-MODULE Be sure to choose the correct Slot number in the rack where your SlotServer reside Click Next and choose a RPI of 100 ms. This is the rate at which the I/O image data will be transferred FieldServer Technologies 1991 Tarob Court Milpitas,

Summary of the content on the page No. 17

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 17 of 34 Click Finish to complete the Module Properties setup 7.3. Step 3: Write Ladder Program to get Input Data from Data Arrays • Add a CPS (Synchronous Copy File) Ladder element to synchronize the incoming Data from the Input Data Arrays. Use the Input Image Data as Source. You can create the Destination Tag by right clicking on Destination and choosing New Tag. FieldServer Technologies 1991 Tarob Court Milpit

Summary of the content on the page No. 18

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 18 of 34 Create a Controller Tag of Type REAL, dimension of 80 for the Destination • Add an EQU (Compare if equal) ladder element to check when the first Data Array has been received. The block number is at offset 2 of the input image. • Finally, add another CPS ladder element to copy the LonWorks Data from the InData_Copy Tag to a new Controller Tag, called Lon_In_01. Also create the Tag by right clicking on Destination a

Summary of the content on the page No. 19

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 19 of 34 Below is the final ladder program to access data from LonWorks Function Block In[0] Very Important Note! It is very important to first make a synchronous copy of the input image data before using it. If this is not done, the input data cannot be guaranteed to be from a specific SlotServer Data Array. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408)

Summary of the content on the page No. 20

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011) Page 20 of 34 7.4. Step 4: Write Ladder Program to Send Output Data to Data Arrays This step demonstrates how to write data to the Data Array Out[0] • Create a Controller Tag called Lon_Out_01 of type REAL[80]. • Add a new rung to the Ladder program and add a MOV element to move a block number value of 1 into Lon_Out_01[2]. • Finally add a CPS (Synchronous Copy File) element to copy the full Lon_Out_01 tag into the Output Image T


Alternative user manuals
# User manual Category Download
1 FieldServer FS-X20 User manual Server 1
2 FieldServer FS-B-OPC-01 User manual Server 0
3 FieldServer Safetran FS-8700-128 User manual Server 4
4 FieldServer SIEMENS TIWAY I FS-8700-31 User manual Server 0
5 FieldServer FS-RA-CLX-FIR User manual Server 1
6 FieldServer FS-RA-CLX-PRO User manual Server 1
7 Edelbrock 1921 User manual Server 0
8 Sony VAIO VGF-HS1 User manual Server 11
9 Sony NAS-SV20DI User manual Server 1
10 3Com 10031370-01 User manual Server 1
11 3Com SuperStack 3 User manual Server 9
12 3Com CS/2500 User manual Server 11
13 8e6 Technologies 8e6 Enterprise Reporter Administrator Console ER User manual Server 0
14 Accton Technology Fike Cheetah FS-8700-48 User manual Server 10
15 Acer AR380 F1 User manual Server 1