FieldServer FS-RA-CLX-PRO user manual

User manual for the device FieldServer FS-RA-CLX-PRO

Device: FieldServer FS-RA-CLX-PRO
Category: Server
Manufacturer: FieldServer
Size: 0.58 MB
Added : 11/5/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FieldServer FS-RA-CLX-PRO. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FieldServer FS-RA-CLX-PRO.

For your convenience

If looking through the FieldServer FS-RA-CLX-PRO user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FieldServer FS-RA-CLX-PRO on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FieldServer FS-RA-CLX-PRO to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FieldServer FS-RA-CLX-PRO User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FieldServer FS-RA-CLX-PRO but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FieldServer FS-RA-CLX-PRO. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



A Sierra Monitor Company






SlotServer Start-Up Guide







APPLICABILITY & EFFECTIVITY

This manual provides instructions for the following FieldServer products:

Description
FS-RA-CLX-BAS
FS-RA-CLX-FIR
FS-RA-CLX-PRO
The instructions are effective for the above as of November 2009
Kernel Version: 5.15
Document Revision: 1

Summary of the content on the page No. 2

SlotServer Start-up Guide Table of Contents TABLE OF CONTENTS 1 Equipment Set-up .................................................................................................................................... 3 1.1 Supplied equipment ............................................................................................................................................ 3 1.2 Third Party Components (Not Supplied by FieldServer Technologies) .....................................

Summary of the content on the page No. 3

SlotServer Start-Up Guide Page 3 of 14 1 EQUIPMENT SET-UP 1.1 SUPPLIED EQUIPMENT USB Flash Drive loaded with:  SlotServer Start-up Guide  SlotServer Configuration Manual  FieldServer Utilities Manual  All FieldServer Driver Supplements  Support Utilities  Any additional folders related to special files configured for a specific FieldServer  Additional components as required - See Driver Manual Supplement for details Accessories:  2-way combi-comb connector for LonW

Summary of the content on the page No. 4

SlotServer Start-Up Guide Page 4 of 14 1.4 SLOTSERVER PORTS AND DISPLAYS Note that there are several hardware ports available on the SlotServer card, but that this SlotServer model only makes use of a select few. The ports and displays of interest are as shown in the diagram below: Scrolling display shows card messages Card Status Indicators show general card status Service Pin for LonWorks Commissioning Communications Status LED’s show status of communications and card software

Summary of the content on the page No. 5

SlotServer Start-Up Guide Page 5 of 14 1.5 TECHNICAL SPECIFICATIONS The following table presents the relevant technical specifications. Slot width 1 BackPlane Current Load 0.6A Operating Temperature 0-60°C (32-140°F) Storage Temperature -40 - 85°C (-40 - 185°F) Humidity 5-95% (Non-Condensing) Allen Bradley Platform: ControlLogix 1756 Rack LonWorks Connection type: TP/FT-10 Ethernet port 10/100 MB/sec. RS-485 port 2-wire, half duplex. UL 60950-1:2003 Approvals CAN/CSA-C22.2

Summary of the content on the page No. 6

SlotServer Start-Up Guide Page 6 of 14 2 INSTALLATION The SlotServer plugs directly into the AB1756 ControlLogix rack. Take note of the slot number used for the SlotServer as this will be needed when configuring the I/O in the RSLogix software. 2.1 POWER UP THE DEVICE Apply power to the device. Refer to the panel to ensure that the SlotServer has powered up successfully. The diagram in Section 1.4 indicates the location of each of these items on the SlotServer panel. Scrollin

Summary of the content on the page No. 7

SlotServer Start-Up Guide Page 7 of 14 2.5 CONNECT USING “REMOTE USER INTERFACE” (RUINET) All configuration file transfers and system diagnostics are executed via the RUI or “Remote User Interface” which is installed with the Utility software. Refer to the FieldServer Utilities manual for further information.  Browse to the Remote User Interface icon in the Start menu directory and click on it.  The RUI menu screen should appear.  If necessary, refer to Appendix A for troublesh

Summary of the content on the page No. 8

SlotServer Start-Up Guide Page 8 of 14  Once download is complete, hit to get back to the main menu and use the "!" option (or simply cycle power to the SlotServer) to put the new file into operation. Note that it is possible to do multiple downloads to the SlotServer before resetting it.  Firmware created by FieldServer Technologies can be downloaded from the configuration file by simply typing “F” from the download menu. Note that FieldServer usually supplies firmware upg

Summary of the content on the page No. 9

SlotServer Start-Up Guide Page 9 of 14 Appendix A. Useful Features Refer to the Configuration Manual for useful configuration features. The unit may be removed under power for convenient swapping of modules. Appendix A.1. LED Functions Service Pin The LonWorks Service pin can be used for commissioning the SlotServer into a LonWorks network. LonSvc Run Node Off Conf Err LonWorks Activity can be determined using this LED as follows: LON LED Activity Sys Err Com Err Explicit Impli

Summary of the content on the page No. 10

SlotServer Start-Up Guide Page 10 of 14 Ethernet Lights These lights are related to the Ethernet network ports provided on the SlotServer. The 10/100 light will be green if the physical connection to the network hub is 10/100 running at 100 MBits/s. If the light is off, the connection is running at 10 MBits/s. The Act (Activity) light will indicate activity on the network. The frequency of Act flashing is directly related to the network activity. It does not necessarily mean

Summary of the content on the page No. 11

SlotServer Start-Up Guide Page 11 of 14 Appendix B. Troubleshooting Appendix B.1. Things to check when communications fail.  Check for loose cabling on the third party network  Verify that the correct program is loaded to the CPU  Verify that the correct data types for the tags have been used. Appendix B.2. Timeout Errors on SlotServer The following remedial action is suggested if timeout errors are experienced:  The PLC is not set to RUN mode - it may still be in PRG mode.

Summary of the content on the page No. 12

SlotServer Start-Up Guide Page 12 of 14 Appendix B.5. Technical Support Before contacting Technical support to report an issue, go to Start|Programs|FieldServer utilities|Tools and browse to Serial Capture. Take a log (See ENotes 26 and 58 in the folder called Library on the USB Flash Drive). Send this log together with the configuration file to support@fieldserver.com for evaluation. Note that while all necessary documentation is shipped with the FieldServer on the USB flash

Summary of the content on the page No. 13

SlotServer Start-Up Guide Page 13 of 14 Appendix C. Vendor Information 1 Appendix C.1. Installing SlotServer on a Remote Rack using CNB Cards Appendix C.1.1. Hardware and Software requirements  Two 1756 racks, one containing the CPU and the other the SlotServer  Two Controlnet CNB cards with connection cables to connect the racks to one other  RSlinx  RSLogix  RSNetworx  SlotServer EDS file (Available on SlotServer CD, or call Technical Support) Appendix C.1.2. Setup  I

Summary of the content on the page No. 14

SlotServer Start-Up Guide Page 14 of 14 Appendix D. Limited Warranty FieldServer Technologies warrants its products to be free from defects in workmanship or material under normal use and service for two years after date of shipment. FieldServer Technologies will repair or replace without charge any equipment found to be defective during the warranty period. Final determination of the nature and responsibility for defective or damaged equipment will be made by FieldServer Technolo


Alternative user manuals
# User manual Category Download
1 FieldServer FS-X20 User manual Server 1
2 FieldServer FS-B-OPC-01 User manual Server 0
3 FieldServer Safetran FS-8700-128 User manual Server 4
4 FieldServer SIEMENS TIWAY I FS-8700-31 User manual Server 0
5 FieldServer FS-RA-CLX-FIR User manual Server 1
6 FieldServer FS-RA-CLX-BAS User manual Server 2
7 Edelbrock 1921 User manual Server 0
8 Sony VAIO VGF-HS1 User manual Server 11
9 Sony NAS-SV20DI User manual Server 1
10 3Com 10031370-01 User manual Server 1
11 3Com SuperStack 3 User manual Server 9
12 3Com CS/2500 User manual Server 11
13 8e6 Technologies 8e6 Enterprise Reporter Administrator Console ER User manual Server 0
14 Accton Technology Fike Cheetah FS-8700-48 User manual Server 10
15 Acer AR380 F1 User manual Server 1