Accton Technology CHEETA 3016P user manual

User manual for the device Accton Technology CHEETA 3016P

Device: Accton Technology CHEETA 3016P
Category: Switch
Manufacturer: Accton Technology
Size: 0.96 MB
Added : 12/31/2013
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Accton Technology CHEETA 3016P. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Accton Technology CHEETA 3016P.

For your convenience

If looking through the Accton Technology CHEETA 3016P user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Accton Technology CHEETA 3016P on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Accton Technology CHEETA 3016P to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Accton Technology CHEETA 3016P User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Accton Technology CHEETA 3016P but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Accton Technology CHEETA 3016P. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CheetaHub Power-3008P/3016P
Quick Installation Guide

Summary of the content on the page No. 2

Quick Installation Guide CheetaHub Power-3008P/16P Fast Ethernet Dual-Speed Hubs with 8/16 10/100Mbps (RJ-45) Ports, and Internal Switch CheetaHub Power-3008P CheetaHub Power-3016P

Summary of the content on the page No. 3

Copyright © 1999 by Accton Technology Corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation. Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. Accton reserves the right to make revis

Summary of the content on the page No. 4

Contents Introduction 1 Installing the Hub 1 Package Contents 1 Description of Hardware 1 Mounting the Hub 2 Stacking Hubs on a Flat Surface 2 Mounting Hubs in a Rack 3 Connecting the Hub System 3 Making a Connection via an RJ-45 Station Port 3 Making a Connection via an MDI Daisy-Chain Port 4 Powering On the Hub 5 Verifying Port Status 5 Verifying System Operation 6 Applications 6 Product Specifications 7 Repeater Criteria 7 Internal Switching Criteria 8 Troubleshooting 8 Diagnosing Hub Indicat

Summary of the content on the page No. 5

ii

Summary of the content on the page No. 6

Quick Installation Guide Introduction The CheetaHub Power-3008P/16P provides 8 (16) RJ-45 ports that automatically adjust to the speed of the attached device (for 10Mbps Ethernet or 100Mbps Fast Ethernet connections). These dual-speed hubs contain two internal repeater buses – one for 10Mbps traffic and another for 100Mbps traffic. Traffic passing between attached devices that operate at the same speed is confined within the appropriate repeater bus. But when traffic must pass between 10 and

Summary of the content on the page No. 7

CheetaHub Power-3008P/3016P containing the destination node via a 2-port switch that connects the two repeater buses. By confining traffic to its respective collision domain, and only forwarding traffic to the other segment when required, the overall load on the network is significantly reduced. These hubs provide a friendly design that simplifies installation and network troubleshooting. The following figure shows the components of the EH3016P: Mounting the Hub These hubs can be placed direct

Summary of the content on the page No. 8

Quick Installation Guide 2. Place the first hub on a firm flat surface where you want to install the stack. 3. Repeat step 1 for each hub before stacking them. The rubber foot pads cushion the hub against shock/vibrations and provide space between each hub for ventilation. Mounting Hubs in a Rack Please comply with the following instructions to ensure that your hub is securely mounted in the rack. 1. Use a standard EIA 19-inch rack. 2. Use the brackets and screws supplied in the rack mounting k

Summary of the content on the page No. 9

CheetaHub Power-3008P/3016P 3. Connect one end of the cable to the RJ-45 port of the network interface card, and the other end to any available (MDI-X) station port on the hub. The RJ-45 ports support 10Mbps and 100Mbps Ethernet connections. When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to ensure that it is properly seated. Using a hub in a stand-alone configuration, you can network up to 8 (16) end nodes.  Do not plug a phone jack connector into any RJ-45 po

Summary of the content on the page No. 10

Quick Installation Guide cabling will be limited to 5 meters (16 feet). The only way to extend the inter- hub cabling, would therefore be to reduce the length of the cabling used to attach the end nodes to the hubs.  Ethernet Switch - There are no formal restrictions on cascade length if a device is connected to a switch, which effectively breaks up the collision domain. When a collision domain is broken up by a device like a switch, cascade length is limited only by the time-out requirement

Summary of the content on the page No. 11

CheetaHub Power-3008P/3016P Port and Hub Status LEDs LEDs Condition Status Power Green Hub is receiving power. Link Yellow Indicates a valid 10BASE-T connection between port and attached device. Green Indicates a valid 100BASE-TX connection between port and attached device. Partition Yellow Port has been partitioned due to an abnormal condition. Col Flashing Indicates that a packet collision has been Yellow detected on the indicated segment. Act Flashing Indicates that the port is transmitting o

Summary of the content on the page No. 12

Quick Installation Guide Connecting to a Network Backbone - You can easily connect to a collapsed backbone switch via the RJ-45 MDI daisy-chain port on the front panel. Because a switch breaks up the collision domain, it can be used to connect multiple CheetaHubs. Product Specifications Repeater Criteria Access Method CSMA/CD, 10 Mbps or 100 Mbps Standards Conformance IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX Communication Rate 10/100 Mbps on all RJ-45 ports Media Supported 10BASE-T - 100Ω C

Summary of the content on the page No. 13

CheetaHub Power-3008P/3016P Maximum Current 0.3A max. @ 110VAC, 0.1A max. @ 240VAC RMS RMS Temperature 0°C to 50°C (32 to 122°F) Standard Operating, -40~70°C (-40~158°F) Storage Humidity 5% to 95% (Noncondensing) Certification CE Mark Emissions FCC Class A, VCCI Class A, EN55022 (CISPR22) Class A Immunity IEC 1000-4-2/3/4/6 Safety CSA/NRTL (C22.2.950, UL 1950), TÜV/GS (EN60950) IEC60950 (CB Report) Internal Switching Criteria Network Bridging Function Filtering, forwarding and learning Switching

Summary of the content on the page No. 14

Quick Installation Guide Power and Cooling Problems If the Power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fan on back of the unit is unobstructed and running prior to shutdown. If you still cannot i

Summary of the content on the page No. 15

CheetaHub Power-3008P/3016P Assignment Assignment Pin (Station Ports) (Daisy-Chain Port) 1+I+ nput Receive Data Output Transmit Data 2-I- nput Receive Data Output Transmit Data 3+O+ utput Transmit Data Input Receive Data 6-O- utput Transmit Data Input Receive Data 4d ,5,7,8Nd ot Use Not Use Schematics for both straight and crossover twisted-pair cable are shown below. Straight-Through Crossover () Hub) () Adapter() Hub (Hub 1+ IRD+ 1+ OTD1+ IRD 1 IRD 2- IRD- 2- OTD2- IRD 2 IRD 3+ OTD+3+ IRD3+ OT

Summary of the content on the page No. 16

Quick Installation Guide VCCI Class A Compliance (Japan) BCIQ Class A Compliance (Taiwan) CE Mark Declaration of Conformance (for EMI and Safety - Europe) This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specifications: EMC: EN55022(1988)/CISPR-22(1985) Class A IEC1000-4-2(1995) 4kV CD, 8kV AD IEC1000-4-3(1995) 3V/m IEC1000-4-4(1995) 1kV - (power line), 0.5kV - (signal line) IEC 1000-4-6(1995) 3Vrms This product complies with the requi

Summary of the content on the page No. 17

CheetaHub Power-3008P/3016P Voltage Cord Set Specifications 1t 20 Volts UL Listed/CSA Certified Cord Se Minimum 18 AWG; type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade, grounding type attachment plug rated 15A, 125V 2t 40 Volts UL Listed/CSA Certified Cord Se (d North America) Minimum 18 AWG; type SVT or SJT three conductor cor Maximum length of 15 feet Tandem blade, grounding type attachment plug rated 15A, 125V 240 Volts Cord Set with H05VV-F cord having three con

Summary of the content on the page No. 18

Quick Installation Guide 15. Zum Netzanschluß dieses Gerätes ist eine geprüfte Leitung zu verwenden. Für einen Nennstrom bis 6A und einem Gerätegewicht größer 3kg ist eine Leitung nicht leichter als 2 H05VV-F, 3G, 0.75mm einzusetzen. Warranty Accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of three years from the date of purchase from Accton or it’s Authorized reseller. For the warranty to apply,

Summary of the content on the page No. 19

EH3008P EH3016P E0999-R02 150052-102


Alternative user manuals
# User manual Category Download
1 Accton Technology 100BASE-TX User manual Switch 3
2 Accton Technology 8se User manual Switch 1
3 Accton Technology 12SE User manual Switch 1
4 Accton Technology ES2027 User manual Switch 0
5 Accton Technology 10BASE-T EH2045S User manual Switch 16
6 Accton Technology 16 User manual Switch 1
7 Accton Technology E0298-R03 User manual Switch 0
8 Accton Technology Accton Fast etherHub 3500 System 12mi SNMP User manual Switch 0
9 Accton Technology ES3008 User manual Switch 12
10 Accton Technology EH3012C User manual Switch 0
11 Accton Technology Direk Tronik ES4524D User manual Switch 3
12 Accton Technology ES3528M-SFP User manual Switch 214
13 Accton Technology ES3526XA User manual Switch 240
14 Accton Technology ES3005 User manual Switch 3
15 Accton Technology Direk Tronik 24/48-Port User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4