Goodman Mfg . Co. LP.CKF50Hz user manual

User manual for the device Goodman Mfg . Co. LP.CKF50Hz

Device: Goodman Mfg . Co. LP.CKF50Hz
Category: Air Conditioner
Manufacturer: Goodman Mfg
Size: 0.46 MB
Added : 2/22/2014
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg . Co. LP.CKF50Hz. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg . Co. LP.CKF50Hz.

For your convenience

If looking through the Goodman Mfg . Co. LP.CKF50Hz user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg . Co. LP.CKF50Hz on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg . Co. LP.CKF50Hz to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg . Co. LP.CKF50Hz User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg . Co. LP.CKF50Hz but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg . Co. LP.CKF50Hz. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL
TECHNICAL MANU TECHNICAL MANUAL AL
CKF 50 Hz
Condensing Units
• Refer to Service Manual RS6100004 for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
RT6111009r4

Summary of the content on the page No. 2

PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. CKF 036 2 M REVISION LEVEL CATEGORY: C: Split Systems ELECTRICAL: 1: 208-230V/1 phase/60Hz 2: 220-240V/1 phase/50Hz PRODUCT FAMILY: 3: 208-230V/3 phase/60Hz K: Air Conditioner 5: 308-415V/3 phase/50Hz NOMINAL CAPACITY 018: 1.5 Tons 024: 2 Tons 036: 3 Tons 042: 3.5

Summary of the content on the page No. 3

PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. CKF24-2M CKF24-2P CKF36-2P CKF24-2N CKF36-5P CKF36-2M CKF48-5P CKF36-2N CKF60-5P CKF36-5M CKF36-5N CKF70-5P CKF48-5M CKF48-5N CKF60-5M CKF60-5N CKF70-5M CKF70-5N * Indicates minor revision & is not used for order entry or inventory management NOTE: CKF**-*P* units are shipped without refrigerant and are pressur

Summary of the content on the page No. 4

PRODUCT DESIGN CKF 50 Hz models are available in 2 through 6 ton sizes. They are designed for 220/240 to 380 volt single phase appli- cations. The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then dis- NOT OK! charged out of the top of the cabinet. B RECOMMENDED OK! These units are designed for free air discharge, so no addi- B B B tional resistance like duct work shall be attached. The suction and liquid line connections on present mo

Summary of the content on the page No. 5

PRODUCT DESIGN Dimensions W D H Model Dimensions - W x D x H CKF24-2* 26" [660] x 26" [660] x 29¾ [756] CKF36-2* 26" [660] x 26" [660] x 29¾ [756] CKF36-5* 26" [660] x 26" [660] x 29¾ [756] CKF48-5* 29" [737] x 29" [737] x 29¾ [756] CKF60-5* 29" [737] x 29" [737] x 32¼ [819] CKF70-5* 29" [737] x 29" [737] x 38¼ [972] [ ] Designate s metric e quivalents 5

Summary of the content on the page No. 6

CONDENSING UNIT SPECIFICATIONS Cooling Capacity, BTUH/kW 24600/7.2 34000/10.0 34000/10.0 44000/12.9 55000/16.1 64000/18.8 Compressor 12.50 17.9 5.3 7.4 9 10.9 R.L. Amps 61.0 97.4 42.0 50.0 74.0 101.0 L.R. Amps 410/275 410/275 410/275 410/275 410/275 410/275 High Pressure Switch-Open / Close Condenser Fan Motor 1/41/4 1/41/4 1/4 1/3 Horsepower F.L. Amps 0.90.9 0.80.8 0.8 1.2 Liquid Line, Inches [mm] O.D.* 3/8 [9.6] 3/8 [9.6] 3/8 [9.6] 3/8 [9.6] 3/8 [9.6] 3/8 [9.6] Suction Line, Inches [mm] O.D.*

Summary of the content on the page No. 7

COOLING PERFORMANCE DATA CKF24-2* 7 EXPANDED PERFORMANCE DATA MODEL: CKF24-2* / A24-00-2RA COOLING OPERATION Outdoor Ambient Temperature 65°F 75°F 85°F 95°F 105°F 115°F 118°F 125°F Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 53 67 71 59 63 67 71 MBh 23.6 24.5 26.8 - 23.1 23.9 26.2 - 22.5 23.4 25.6 - 21.6 22.3 24.5 - 20.0 20.8 22.8 - 18.5 19.2 21.1 - 17.3 18.0 19.7 - 16.8 17.4 19.1 - S/T 0.69 0.57 0.40 - 0.71 0.59 0

Summary of the content on the page No. 8

COOLING PERFORMANCE DATA CKF24-2* 8 EXPANDED PERFORMANCE DATA MODEL: CKF24-2* / A24-00-2RA COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 118°F 125°F Entering Indoor Wet Bulb Temperature IDB*Airflow 59 6367715963 67 71 59 63 67 71 59 63 67 71 596367 71 5963 67 71 59 53 67 71 59 63 67 71 MBh 24.4 25.0 26.7 28.5 23.9 24.4 26.1 27.9 23.3 23.8 25.5 27.2 22.3 22.8 24.4 26.0 20.8 21.2 22.7 24.2 19.2 19.6 20.9 22.4 17.9 18.3 19.6 20.9 17.4 17.8 19.0 20.3 S/T 0.86 0.80 0.65 0.5 0.89

Summary of the content on the page No. 9

COOLING PERFORMANCE DATA CKF36-2* 9 EXPANDED PERFORMANCE DATA MODEL: CKF36-2* / A36-00-2 COOLING OPERATION Outdoor Ambient Temperature 65°F 75°F 85°F 95°F 105°F 115°F 118°F 125°F Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 53 67 71 59 63 67 71 MBh 32.5 33.6 36.9 - 31.7 32.9 36.0 - 31.0 32.1 35.2 - 29.6 30.7 33.7 - 27.6 28.6 31.3 - 25.5 26.4 28.9 - 23.8 24.7 27.1 - 23.1 24.0 26.3 - S/T 0.71 0.59 0.41 - 0.74 0.62 0.4

Summary of the content on the page No. 10

CKF36-2* COOLING PERFORMANCE DATA 10 EXPANDED PERFORMANCE DATA MODEL: CKF36-2* / A36-00-2 COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 118°F 125°F Entering Indoor Wet Bulb Temperature IDB*Airflow 596367715963677159 63 67 71 59 63 67 71 596367715963 67 71 59 53 67 71 59 63 67 71 MBh 33.6 34.3 36.7 39.2 32.8 33.5 35.8 38.3 32.1 32.8 35.0 37.4 30.7 31.4 33.5 35.8 28.5 29.2 31.2 33.3 26.4 27.0 28.8 30.8 24.7 25.2 26.9 28.8 23.9 24.5 26.1 27.9 S/T 0.89 0.83 0.68 0.5 0.92 0.86 0

Summary of the content on the page No. 11

COOLING PERFORMANCE DATA CKF36-5* 11 EXPANDED PERFORMANCE DATA MODEL: CKF36-5* / AR36-00-2 COOLING OPERATION Outdoor Ambient Temperature 65°F 75°F 85°F 95°F 105°F 115°F 118°F 125°F Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 53 67 71 59 63 67 71 MBh 31.9 33.0 36.2 - 31.1 32.3 35.3 - 30.4 31.5 34.5 - 29.6 30.7 33.7 - 28.2 29.2 32.0 - 26.1 27.0 29.6 - 25.4 26.3 28.8 - 25.1 26.0 28.5 - S/T 0.72 0.60 0.42 - 0.75 0.62 0

Summary of the content on the page No. 12

COOLING PERFORMANCE DATA CKF36-5* 12 EXPANDED PERFORMANCE DATA MODEL: CKF36-5* / AR36-00-2 COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 118°F 125°F Entering Indoor Wet Bulb Temperature IDB*Airflow 59636771596367 71 59 63 67 71 59 63 67 71 59 6367 71 5963 67 71 59 53 67 71 59 63 67 71 MBh 33.0 33.7 36.0 38.5 32.2 32.9 35.2 37.6 31.4 32.1 34.3 36.7 30.7 31.4 33.5 35.8 29.1 29.8 31.8 34.0 27.0 27.6 29.5 31.5 26.3 26.8 28.7 30.6 25.9 26.5 28.3 30.3 S/T 0.90 0.84 0.68 0.5 0.93

Summary of the content on the page No. 13

CKF48-5* COOLING PERFORMANCE DATA 13 EXPANDED PERFORMANCE DATA MODEL: CKF48-5* / A48-00-2 COOLING OPERATION Outdoor Ambient Temperature 65°F 75°F 85°F 95°F 105°F 115°F 118°F 125°F Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 53 67 71 59 63 67 71 MBh 42.5 44.0 48.2 - 41.5 43.0 47.1 - 40.5 42.0 46.0 - 39.5 41.0 44.9 - 37.5 38.9 42.6 - 34.8 36.0 39.5 - 32.6 33.8 37.0 - 31.6 32.8 35.9 - S/T 0.74 0.61 0.43 - 0.76 0.64 0.

Summary of the content on the page No. 14

COOLING PERFORMANCE DATA CKF48-5* 14 EXPANDED PERFORMANCE DATA MODEL: CKF48-5* / A48-00-2 COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 118°F 125°F Entering Indoor Wet Bulb Temperature IDB*Airflow 59 636771 59 6367 71 59 63 677159 63 67 71 596367 71 5963 67 71 59 53 67 71 59 63 67 71 MBh 44.0 44.9 48.0 51.3 43.0 43.9 46.9 50.1 41.9 42.8 45.8 48.9 40.9 41.8 44.7 47.7 38.9 39.7 42.4 45.4 36.0 36.8 39.3 42.0 33.7 34.4 36.8 39.3 32.7 33.4 35.7 38.2 S/T 0.92 0.86 0.70 0.5 0.95 0

Summary of the content on the page No. 15

CKF60-5* COOLING PERFORMANCE DATA 15 EXPANDED PERFORMANCE DATA MODEL: CKF60-5* / A60-00-2 COOLING OPERATION Outdoor Ambient Temperature 65°F 75°F 85°F 95°F 105°F 115°F 118°F 125°F Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 53 67 71 59 63 67 71 MBh 53.1 55.0 60.3 - 51.9 53.8 58.9 - 50.6 52.5 57.5 - 49.4 51.2 56.1 - 46.9 48.6 53.3 - 43.5 45.1 49.4 - 40.7 42.2 46.2 - 39.5 41.0 44.9 - S/T 0.71 0.59 0.41 - 0.73 0.61 0.

Summary of the content on the page No. 16

COOLING PERFORMANCE DATA CKF60-5* 16 EXPANDED PERFORMANCE DATA MODEL: CKF60-5* / A60-00-2 COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 118°F 125°F Entering Indoor Wet Bulb Temperature IDB*Airflow 596367715963 677159 63 677159 63 67 71 596367 71 5963 67 71 59 53 67 71 59 63 67 71 MBh 55.0 56.2 60.0 64.2 53.7 54.9 58.6 62.7 52.4 53.6 57.2 61.2 51.1 52.3 55.8 59.7 48.6 49.6 53.0 56.7 45.0 46.0 49.1 52.5 42.1 43.1 46.0 49.2 40.9 41.8 44.7 47.7 S/T 0.88 0.83 0.67 0.5 0.92 0.86

Summary of the content on the page No. 17

COOLING PERFORMANCE DATA CKF70-5* 17 EXPANDED PERFORMANCE DATA MODEL: CKF70-5* / A60-00-2 COOLING OPERATION Outdoor Ambient Temperature 65°F 75°F 85°F 95°F 105°F 115°F 118°F 125°F Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 53 67 71 59 63 67 71 MBh 58.9 61.1 66.9 - 57.5 59.6 65.3 - 56.2 58.2 63.8 - 54.8 56.8 62.2 - 52.1 54.0 59.1 - 48.2 50.0 54.8 - 45.2 46.8 51.3 - 43.8 45.4 49.8 - S/T 0.68 0.57 0.39 - 0.71 0.59 0.

Summary of the content on the page No. 18

COOLING PERFORMANCE DATA CKF70-5* 18 EXPANDED PERFORMANCE DATA MODEL: CKF70-5* / A60-00-2 COOLING OPERATION Outdoor Ambient Temperature 65 75 85 95 105 115 118°F 125°F Entering Indoor Wet Bulb Temperature IDB*Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 6367 71 59 63 67 71 59 63 67 71595367 7159636771 MBh 61.0 62.3 66.6 71.2 59.5 60.9 65.0 69.5 58.1 59.4 63.5 67.8 56.7 58.0 61.9 66.2 53.9 55.1 58.8 62.9 49.9 51.0 54.5 58.2 46.7 47.8 51.0 54.5 45.4 46.4 49.5 52.9 S/T 0.85 0.80 0.65 0.5 0.88 0

Summary of the content on the page No. 19

PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a

Summary of the content on the page No. 20

WIRING DIAGRAMS CKF[24-36]M/N/P HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 20 MAIN MAIN CONTROL BOX LVJB OUTDOOR POWER SUPPLY SEE RATING PLATE YL Y NOTE 1 T1 T2 BL C L1 L2 5 2 SR 1 SC C Y2 C SCP Y1 R2 R1 IO H C S C RCCF BL COMP F BK COLOR CODE BL


Alternative user manuals
# User manual Category Download
1 Goodman Mfg 000 BTUH + 115 Volt User manual Air Conditioner 59
2 Goodman Mfg ARPT User manual Air Conditioner 12
3 Goodman Mfg 13 SEER GPC13M User manual Air Conditioner 22
4 Goodman Mfg ADPF User manual Air Conditioner 4
5 Goodman Mfg 10.3 EER User manual Air Conditioner 7
6 Goodman Mfg AEPT User manual Air Conditioner 2
7 Goodman Mfg ARUF182416CA User manual Air Conditioner 37
8 Goodman Mfg A/GPG13 M User manual Air Conditioner 2
9 Goodman Mfg ARPF User manual Air Conditioner 6
10 Goodman Mfg 13 SEER GPC13H User manual Air Conditioner 4
11 Goodman Mfg ARUF172916CA User manual Air Conditioner 7
12 Goodman Mfg ARUF User manual Air Conditioner 11
13 Goodman Mfg ARUF303016CA User manual Air Conditioner 33
14 Goodman Mfg ARUF193116CA User manual Air Conditioner 10
15 Goodman Mfg ARUF364216CA User manual Air Conditioner 26
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21