Goodman Mfg . Co. LP.RS6300011 user manual

User manual for the device Goodman Mfg . Co. LP.RS6300011

Device: Goodman Mfg . Co. LP.RS6300011
Category: Air Conditioner
Manufacturer: Goodman Mfg
Size: 0.77 MB
Added : 2/22/2014
Number of pages: 43
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg . Co. LP.RS6300011. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg . Co. LP.RS6300011.

For your convenience

If looking through the Goodman Mfg . Co. LP.RS6300011 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg . Co. LP.RS6300011 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg . Co. LP.RS6300011 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg . Co. LP.RS6300011 User manual - Online PDF
Advertisement
« Page 1 of 43 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg . Co. LP.RS6300011 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg . Co. LP.RS6300011. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL
TECHNICAL MANU TECHNICAL MANUAL AL
GPC 14 SEER R-410A
Package Air Conditioners
with R-410A
• Refer to Service Manual RS6300011 (Horizontal)
for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
• Models qualify for the 2009 and 2010 Federal Tax Credits for Energy

Summary of the content on the page No. 2

PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GP C 14 24 H 41 A A VOLTAGE: BRAND: 1: 208-230v MINOR REVISION: ® 1ph/60Hz G: Goodman A: Initial Release PRODUCT Brand FAMILY: C: Cooling REFRIGERANT: 4: R-410A PRODUCT PRODUCT TYPE: MAJOR REVISION: SERIES: Package Unit A: Initial Release CONFIGURATION: SEER Rating H: Horizo

Summary of the content on the page No. 3

PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. 5mm GPC1424H41AA GPC1424H41AB GPC1430H41AA GPC1430H41AB GPC1436H41AA GPC1436H41AB GPC1442H41AA GPC1442H41AB GPC1448H41AA GPC1448H41AB GPC1460H41AA AB model specific 5 mm information begins on page 28. Models qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency** **Note th

Summary of the content on the page No. 4

PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- - Due to their design Scroll Compressors are inherently lations only in either residential or light commercial applica- more tolerant of liquid refrigerant. NOTE: Even though the tions. compressor section of a Scroll compressor is more toler- ant of liquid refrigerant, continued floodback or flooded The connecting ductwork (Supply and Return) can be con- start conditions may wash oil from the bearing surfaces nected for ei

Summary of the content on the page No. 5

UNIT PLENUM PLATFORM PRODUCT DESIGN In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- 36" stallations), the installer must provide service platform for ser- vice person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the Uniform Mechanical Code Section 305. NOTE: Unit can also use roof curb. 24" WARNING TO PREVENT POSSIBLE PROPERTY DAMAGE, THE UNIT SHOULD REM

Summary of the content on the page No. 6

PRODUCT DIMENSIONS GPC14[24-60]H41A* A 14.000 4.512 4.500 14.000 6.500 14.000 SUPPLY RETURN BACK VIEW (DUCT OPENINGS) 66.542 B 34.075 Chassis Model A B GPC1424 33 30½ Small GPC1430 33 30½ GPC1436 33 35½ Medium GPC1442 33 35½ GPC1448 33 38½ Large GPC1460 33 38½ Dimensions in inches 6

Summary of the content on the page No. 7

PRODUCT DESIGN GPC14[24-60]H41A* HKR ELECTRICAL DATA Circuit #1 Circuit #2 Maximum Maximum Actual Minimum Circuit Minimum Circuit Model and Heat Kit Usage Overcurrent Overcurrent kW & BTU Ampacity Ampacity at 240V Protection (amps) Protection (amps) at 208 / 240V at 208 / 240V at 208 / 240V at 208 / 240V GPH1424H41A* HKR05*,C* 24 / 27 30 / 30 ---- ---- 4.75 / 16,200 HKR08*,C* 33 / 28 40 / 40 ---- ---- 7.00 / 23,800 HKR10*,C* 45 / 51 60 / 60 ---- ---- 9.50 / 32,400 GPH1430H41A* HKR05*,C* 24 / 27

Summary of the content on the page No. 8

GPC14[24-60]H41A* ACCESSORIES Part Number Description OT18-60A Outdoor Thermostat Kit w/Lockout Stat OT/EHR18-60 Emergency Heat Relay Kit HKR Electric Heat Kit PCCP101-103 Roof Curb PCP101-103 Downflow Plenum Kit PCP101-103R8 Downflow Plenum Kit w/ R-8 Insulation GPCED101-103 Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103 GPHED101-103 Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103 GPCEH101-103 Horizontal Economizer for GPC-(H) A/C GPHEH101-103 Horizonta

Summary of the content on the page No. 9

GPC14[24-60]H41A* BLOWER PERFORMANCE DATA Dry Coil Data E.S.P (In. of H O) 2 Model Speed Volts 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM 934 759 755 638 581 489 - - T1 230 WATTS 957776738390 - - CFM 990 837 801 744 696 652 601 - T2,T3 230 WATTS 107 94 105 110 119 133 142 - CFM 1061 989 947 925 876 - - - T4, T5 230 WATTS 126 134 146 158 169 - - - CFM 1022 929 894 829 797 748 695 643 T1 230 WATTS 116 114 126 134 144 156 168 173 CFM 1103 1063 1012 962 937 - - - T2,T3 230 WATTS 142 154 165 173 185 -

Summary of the content on the page No. 10

BLOWER PERFORMANCE DATA 10 BTU OUTPUT vs TEMPERATURE RISE CHART 100 600 CFM 90 700 80 800 900 1000 70 1100 1200 60 1400 1600 50 1800 2000 2200 40 2400 CFM 30 FORMULAS BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT 20 RISE = ÷ CFM 1.08 10 100 30 40 50 60 70 80 90 110 120 130 140 150 OUTPUT BTU/HR x 1000 TEMPERATURE RISE

Summary of the content on the page No. 11

PACKAGE COOLING SPECIFICATIONS GPC14[24-30]H41AA GPC1424H41* GPC1430H41* COOLING COOLING CAPACITY, BTUH 24,600 28,400 CAPACITY SEER / EER 14.5 / 12.1 14.0 / 12.1 VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 UNIT ELECTRICAL AMPS (TOTAL) 10.5 13.16 SPECIFICATION MINIMUM CIRCUIT AMPACITY 12.5 15.6 (1) 20 25 MAXIMUM OVERCURRENT PROTECTION COMPRESSOR TYPE RECIP RECIP RATED LOAD AMPS 7.9 9.8 LOCKED ROTOR AMPS 41 55 CONDENSER HORSEPOWER 1/6 1/4 RPM 815 830 FAN MOTOR FULL LOAD AMPS 1.1 1.5 LOCKED ROT

Summary of the content on the page No. 12

PACKAGE COOLING SPECIFICATIONS GPC14[36-42]H41AA GPC1436H41* GPC1442H41* COOLING CAPACITY, BTUH 35,600 40,000 COOLING CAPACITY SEER / EER 14.0 / 12.0 14.2/ 12.0 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 AMPS (TOTAL) 20.06 22.2 ELECTRICAL SPECIFICATION MINIMUM CIRCUIT AMPACITY 24.2 26.6 (1) 40 40 MAXIMUM OVERCURRENT PROTECTION COMPRESSOR TYPE SCROLL SCROLL RATED LOAD AMPS 16.7 17.9 LOCKED ROTOR AMPS 79 112 CONDENSER HORSEPOWER 1/4 1/4 FAN MOTOR RPM 830 1075 FULL LOAD AMPS 1.5 1.4 LOCK

Summary of the content on the page No. 13

PACKAGE COOLING SPECIFICATIONS GPC14[48-60]H41AA GPC1448H41* GPC1460H41* COOLING COOLING CAPACITY, BTUH 46,500 57,500 CAPACITY SEER / EER 14.5 / 12.0 14.5 / 12.0 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 ELECTRICAL AMPS (TOTAL) 24.2 30.7 SPECIFICATION MINIMUM CIRCUIT AMPACITY 29.1 37.3 (1) 45 60 MAXIMUM OVERCURRENT PROTECTION TYPE SCROLL SCROLL COMPRESSOR RATED LOAD AMPS 19.9 26.4 LOCKED ROTOR AMPS 109 134 CONDENSER HORSEPOWER 1/4 1/4 RPM 1075 1075 FAN MOTOR FULL LOAD AMPS 1.4 1.4 LOC

Summary of the content on the page No. 14

COOLING PERFORMANCE DATA GPC1424H41AA 14 MODEL: GPC1424H41A* EXPANDED PERFORMANCE DATA COOLING OPERATION Design Subcooling, 9 ± 2°F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB* Airflow 5963677159 636771596367 7159 63 67 71 5963677159 636771 MBh 24.1 25.0 27.4 - 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25

Summary of the content on the page No. 15

COOLING PERFORMANCE DATA GPC1424H41AA 15 MODEL: GPC1424H41A* EXPANDED PERFORMANCE DATA COOLING OPERATION Design Subcooling, 9 ± 2°F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB* Airflow 5963677159 636771596367 7159 63 67 71 5963677159 636771 MBh 25.0 25.5 27.2 29.1 24.4 24.9 26.6 28.4 23.8 24.3 26.0 27.8 23.

Summary of the content on the page No. 16

COOLING PERFORMANCE DATA GPC1430H41AA 16 MODEL: GPC1430H41A* COOLING OPERATION EXPANDED PERFORMANCE DATA Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB* Airflow 5963677159 636771596367 7159 63 67 71 5963677159 636771 MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 26.5 27.5 30.1 - 25.9 26.8

Summary of the content on the page No. 17

COOLING PERFORMANCE DATA GPC1430H41AA 17 MODEL: GPC1430H41A* EXPANDED PERFORMANCE DATA COOLING OPERATION Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB* Airflow 5963677159 636771596367 7159 63 67 71 5963677159 636771 MBh 28.8 29.4 31.4 33.6 28.1 28.7 30.7 32.8 27.5 28.1 30.0 32.1

Summary of the content on the page No. 18

COOLING PERFORMANCE DATA GPC1436H41AA 18 MODEL: GPC1436H41A* COOLING OPERATION EXPANDED PERFORMANCE DATA Design Subcooling, 10 ±2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9 ±2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB* Airflow 5963677159 636771596367 7159 63 67 71 5963677159 636771 MBh 34.9 36.2 39.6 - 34.1 35.3 38.7 - 33.3 34.5 37.8 - 32.5 33.6 36

Summary of the content on the page No. 19

COOLING PERFORMANCE DATA GPC1436H41AA 19 MODEL: GPC1436H41A* EXPANDED PERFORMANCE DATA COOLING OPERATION Design Subcooling, 10 ±2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9 ±2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB* Airflow 5963677159 636771596367 7159 63 67 71 5963677159 636771 MBh 36.1 36.9 39.4 42.1 35.3 36.0 38.5 41.2 34.4 35.2 37.6 40.2 33.

Summary of the content on the page No. 20

COOLING PERFORMANCE DATA GPC1442H41AA 20 MODEL: GPC1442H41A* COOLING OPERATION EXPANDED PERFORMANCE DATA Design Subcooling, 8 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8 ± 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB* Airflow 596367 7159 6367 71596367 71 59 63 67 71 59 6367 7159 63 6771 MBh 39.7 41.1 45.1 - 38.8 40.2 44.0 - 37.8 39.2 43.0 - 36.9


Alternative user manuals
# User manual Category Download
1 Goodman Mfg 000 BTUH + 115 Volt User manual Air Conditioner 59
2 Goodman Mfg ARPT User manual Air Conditioner 12
3 Goodman Mfg 13 SEER GPC13M User manual Air Conditioner 22
4 Goodman Mfg ADPF User manual Air Conditioner 4
5 Goodman Mfg 10.3 EER User manual Air Conditioner 7
6 Goodman Mfg AEPT User manual Air Conditioner 2
7 Goodman Mfg ARUF182416CA User manual Air Conditioner 37
8 Goodman Mfg A/GPG13 M User manual Air Conditioner 2
9 Goodman Mfg ARPF User manual Air Conditioner 6
10 Goodman Mfg 13 SEER GPC13H User manual Air Conditioner 4
11 Goodman Mfg ARUF172916CA User manual Air Conditioner 7
12 Goodman Mfg ARUF User manual Air Conditioner 11
13 Goodman Mfg ARUF303016CA User manual Air Conditioner 33
14 Goodman Mfg ARUF193116CA User manual Air Conditioner 10
15 Goodman Mfg ARUF364216CA User manual Air Conditioner 26
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21