Goodman Mfg Split System Condensing Units IO-101G user manual

User manual for the device Goodman Mfg Split System Condensing Units IO-101G

Device: Goodman Mfg Split System Condensing Units IO-101G
Category: Air Conditioner
Manufacturer: Goodman Mfg
Size: 0.37 MB
Added : 2/22/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg Split System Condensing Units IO-101G. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg Split System Condensing Units IO-101G.

For your convenience

If looking through the Goodman Mfg Split System Condensing Units IO-101G user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg Split System Condensing Units IO-101G on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg Split System Condensing Units IO-101G to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg Split System Condensing Units IO-101G User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg Split System Condensing Units IO-101G but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg Split System Condensing Units IO-101G. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION & OPERATING
INSTRUCTIONS for
SPLIT SYSTEM
CONDENSING UNITS
All information contained herein is subject to change without notice.
Goodman Manufacturing Company, L.P.
I0-101G 2550 North Loop West, Suite 400, Houston, TX 77092 06/04
www.goodmanmfg.com
© 2003-2004 Goodman Manufacturing Company, L.P.

Summary of the content on the page No. 2

INDEX company. Check the unit model number, specifications, electrical characteristics and accessories to determine if Important Message to Homeowner ...................... 2 they are correct. In the event an incorrect unit is shipped, it must be returned to the supplier and must NOT be Codes and Regulations ....................................... 2 installed. The manufacturer assumes no responsibility for Inspection ............................................................ 2 installation of

Summary of the content on the page No. 3

This “close to the wall” application minimizes exposed Close to the wall application assures free, unobstructed tubing and wiring and reduces the space for children to air to the other two sides. In more confined application run around the unit. This will help to avoid possible spaces, such as corners, provide a minimum 10” clearance damage to the tubes or wiring and/or personal injury. on all air inlet sides. Allow 18” minimum for service access to the compressor compartment and controls. Th

Summary of the content on the page No. 4

consideration is given the weather-tight integrity of the roof. Field Connection to the Valve and Valve Opening The condensing unit contains moving components and can 1. Tubing should be cut square. Make sure it is round vibrate; therefore, sound is also a consideration in rooftop and free of burrs at the connecting ends. Clean the application. Since this unit discharges warm condenser tubing to prevent contaminants from entering the air from the top with cooler air being drawn in three sides

Summary of the content on the page No. 5

Superheat Determination The recommended procedure for processing and charge 1. Read suction pressure. Using Table 3, determine adjustment is as follows: saturated suction temperature. 1. Connect vacuum pump to both base valve service 2. Read suction line temperature. ports. 3. Use the following formula to determine superheat: 2. Evacuate tubing and evaporator through liquid and suction base valve ports, to 500 microns or less for a Superheat = Suction Line Temp. - Saturated Suction Temp. minimu

Summary of the content on the page No. 6

NOTE: System with over 50’ separation between SPECIAL NOTE: Systems with MORE than 15’ of condensing unit and evaporator may require oil charge interconnecting tubing, please refer to Table 5 for line adjustment. charge allowance per foot of tubing. LINE CHARGE ALLOWANCE (R-22) (oz./ft.) OIL CHARGE ADJUSTMENT LINE LIQUID SUCTION UNIT MODEL ADDITIONAL OIL CHARGE PER EACH O. D. (IN) LINE LINE (TONS) ADDITIONAL 10' OF LINE (OZ.)* 1/4 0.22 1 - 1 1/2 0.25 3/8 0.58 2 - 5 0.5 1/2 1.14 *Use either Tex

Summary of the content on the page No. 7

WIRING DIAGRAMS ALT. DOUBLE OUTDOOR CONTROL BOX POLE CONTACTOR OUTDOOR POWER SUPPLY PU T1 T2 R CRANKCASE HEATER C C C R L2 L1 O (IF USED) O F N N T T R L1 L2 A A HERM Y BK R C C Y T T BK R BR O COMPRESSOR O T2 C T1 COMPRESSOR/FAN R R R MOTOR CAPACITOR T1 T2 OUTDOOR POWER COMPRESSOR SUPPLY - (SEE INTERNAL S Y UNIT RATING OVERLOAD PLATE) USE COPPER PU L1 L2 CONDUCTORS ONLY USE L1 FOR NEUTRAL OR GROUNDED SUPPLY START ASSIST FAN MOTOR IF USED START ASSIST Y (IF USED) PU (START ASSIST IF USED) EQUIPM

Summary of the content on the page No. 8

NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficiency. We have designed these units to significantly reduce the most frequent causes of product failure. They are simple to service and forgiving to operate. We use quality materials and components. Finally, every unit is run tested before it leaves the factory.


Alternative user manuals
# User manual Category Download
1 Goodman Mfg 000 BTUH + 115 Volt User manual Air Conditioner 59
2 Goodman Mfg ARPT User manual Air Conditioner 12
3 Goodman Mfg 13 SEER GPC13M User manual Air Conditioner 22
4 Goodman Mfg ADPF User manual Air Conditioner 4
5 Goodman Mfg 10.3 EER User manual Air Conditioner 7
6 Goodman Mfg AEPT User manual Air Conditioner 2
7 Goodman Mfg ARUF182416CA User manual Air Conditioner 37
8 Goodman Mfg A/GPG13 M User manual Air Conditioner 2
9 Goodman Mfg ARPF User manual Air Conditioner 6
10 Goodman Mfg 13 SEER GPC13H User manual Air Conditioner 4
11 Goodman Mfg ARUF172916CA User manual Air Conditioner 7
12 Goodman Mfg ARUF User manual Air Conditioner 11
13 Goodman Mfg ARUF303016CA User manual Air Conditioner 33
14 Goodman Mfg ARUF193116CA User manual Air Conditioner 10
15 Goodman Mfg ARUF364216CA User manual Air Conditioner 26
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21