Johnson Controls Inc.22 SEER user manual

User manual for the device Johnson Controls Inc.22 SEER

Device: Johnson Controls Inc.22 SEER
Category: Air Conditioner
Manufacturer: Johnson Controls
Size: 2.42 MB
Added : 1/16/2014
Number of pages: 46
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Johnson Controls Inc.22 SEER. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Johnson Controls Inc.22 SEER.

For your convenience

If looking through the Johnson Controls Inc.22 SEER user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Johnson Controls Inc.22 SEER on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Johnson Controls Inc.22 SEER to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Johnson Controls Inc.22 SEER User manual - Online PDF
Advertisement
« Page 1 of 46 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Johnson Controls Inc.22 SEER but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Johnson Controls Inc.22 SEER. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION MANUAL
PREMIUM DUCTLESS SINGLE-SPLIT
AIR CONDITIONERS AND HEAT PUMPS
MODELS: 22 SEER
3/4 to 3 TONS – 1 PHASE
LIST OF SECTIONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FLARING WORK AND PIPING CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . 12
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 INDOOR UNIT INSTALLATION . . . . .

Summary of the content on the page No. 2

898841-UIM-B-0113 WARNING indicates a potentially hazardous situation, which, if not SECTION I: GENERAL avoided, could result in death or serious injury. These instructions are intended as a general guide and do not super- CAUTION indicates a potentially hazardous situation, which, if not sede local codes in any way. Consult authorities having jurisdiction avoided may result in minor or moderate injury. It is also used to before installation. alert against unsafe practices and hazards involving

Summary of the content on the page No. 3

898841-UIM-B-0113 TABLE 1: Indoor Parts Flare nut 1/4" for small line on all size units Remote Control 1 1 except 30K which uses 5/8". Cable routing guide with mounting Batteries (AAA) 2 1 hardware (18 - 24 kBtu systems only) Wall mounting bracket 09, 12 & 18 kBtu (5) Installation Manual 1 screws 24K kBtu (10) Foam tube insulation User’s Information (for condensate line 1 1 Manual attached to indoor unit) ASSEMBLED OUTDOOR UNIT 2. Select a location where the condensate can be easily dra

Summary of the content on the page No. 4

898841-UIM-B-0113 NOTICE In rooms where inverter type fluorescent lamps are used, the signal from the wireless remote controller may not be received. INSTALL UNIT AWAY FROM WINDOW OUTDOOR UNIT (SEE FIGURE 3 FOR INSTALLATION DIMENSIONS) 1. Some localities are adopting sound ordinances based on the unit's E F sound level registered from the adjacent property, not from the property where the unit is installed. Install the unit as far as possible from the property line. G 2. When possible, do not i

Summary of the content on the page No. 5

898841-UIM-B-0113 Solid conductor AWG14 or stranded conductor AWG14 are the MINI- MUM allowable wire sizes. There are some applications that will require larger gauge conductors depending on the voltage and amperage rat- ings on the data plate and the distance that the conductors will be routed. It is the installing contractor's responsibility to properly size the electrical conductors for the equipment and for the application. All of the indoor units and outdoor units should have the electrica

Summary of the content on the page No. 6

898841-UIM-B-0113 TABLE 4: Heat Pump Electrical Specifications INDOOR UNIT Heat Pumps DHPM09NWM42Q1 DHPM09NWM41Q1 DHPM12NWM42Q1 DHPM12NWM41Q1 Power Supply (V, Phase, Hz) 208/230V/1 115V/1 208/230V/1 115V/1 Min. Circuit Ampacity 10 16 10 16 Fan Motor (F.L.A) 0.2 0.38 0.2 0.38 INDOOR UNIT Heat Pumps DHPM18NWM42Q1 DHPM24NWM42Q1 DHPM30NWM42Q1 DHPM36NWM42Q1 Power Supply (V, Phase, Hz) 208/230V/1/60HZ 208/230V/1/60HZ 208/230V/1/60HZ 208/230V/1/60HZ Min. Circuit Ampacity 16A 16A 15 23 Fan Motor (F.L.A)

Summary of the content on the page No. 7

898841-UIM-B-0113 TABLE 6: Refrigerant Line Set Requirements AC & HP Indoor Units D(C,H)PM09NWM D(C,H)PM12NWM D(C,H)PM18NWM D(C,H)PM24NWM DHPM30NWM D(C,H)PM36NWM AC & HP Outdoor Units D(C,H)PM09CSM D(C,H)PM12CSM D(C,H)PM18CSM D(C,H)PM24CSM DHPM30CSM D(C,H)PM36CSM Connection Pipe length ft. 24.6 24.6 24.6 24.6 24.6 24.6 Connection Pipe Gas oz/ft. 0.2 0.2 0.2 0.2 0.5 0.5 Additional Charge Outer Diameter Liquid Pipe Inch 1/4 1/4 1/4 1/4 1/4 1/4 Outer Diameter Gas Pipe Inch 3/8 3/8 1/2 1/2 5/8

Summary of the content on the page No. 8

898841-UIM-B-0113 SECTION VIII: UNIT DIMENSIONS A B C 09K 12K 27.3 (693) 21.3 (541) 18K 2.1 (53) 7.8 (198) 2.2 (56) 5.3 (135) 10.9 (277) 11.8 (300) 2.2 (56) 2.2 (56) 2.2 (56) 2 (51) 2 (51) 1.8 (46) .6 (15) .6 (15) 4 (101) 5 (127) 6.3 4.9 22.2 (564) (160) (124) 3.3 (84) 33.3 (846) 40.1 (1018) 24K 7.4 27 (686) 30K & 36K (188) 1 (25) 2.6 (66) 2.6 (66) 2.6 (66) 2.6 (66) 1 (25) 1.8 (46) 4 22.6 (574) 2.5 (64) 4 (102) 3.5 (89) 1.4 (36) (102) FIGURE 6: Indoor Unit Mounting Brackets with Weights & Dim

Summary of the content on the page No. 9

898841-UIM-B-0113 SECTION IX: TORQUE REQUIREMENTS LEVELING DEVICE Mark on the middle of it WALL WALL FOR CAPS AND FASTNERS Space Space to the to the When servicing or repairing HVAC components, ensure the fasteners wall wall are appropriately tightened. The table below provides torque values for 5.9inch 5.9inch above above fasteners. TABLE 9: Caps and Fasteners Torque Requirements Recommended Torque Left Right (REAR PIPING HOLE) (REAR PIPING HOLE) Parts English Metric (ft. - lb.) (Newton Meter

Summary of the content on the page No. 10

898841-UIM-B-0113 TERMINAL BLOCK Mis-wiring could damage unit or cause communication errors between indoor and outdoor unit. GROUND TERMINAL COVER WIRE SCREW 1. Remove the front panel. 2. Open the front panel upward and pull it toward you. SCREW 3. Remove the terminal cover and cord clamp. 4. Insert the connecting cable (according to local codes) into the pipe CORD CLAMP hole on the wall.See Figure 11. CONNECTING CABLE 5. Pull the connecting cable through the cable slot on the rear case so that

Summary of the content on the page No. 11

898841-UIM-B-0113 LEFT OR LEFT REAR PIPING For Left Side Utility Bundle Exit - Cut out the corner of the right/left plastic cabinet with a hacksaw or similar tool. Make sure you reattach the drain hose and the drain cap in case of left or left rear piping. Otherwise, it could cause drops of water to drip from the drain hose. 1. Put the refrigerant piping and the drain hose together then firmly apply felt tape from the end. 2. Pull out the drain cap at the rear right of the indoor unit. 3. Pull o

Summary of the content on the page No. 12

898841-UIM-B-0113 SECTION XIII: FLARING WORK AND PIPING CONNECTIONS 1. In order to align the drain hose and drain cap, be sure to insert FLARING WORK securely and vertically. Incline insertion will cause water leak- Main cause for refrigerant leakage is due to defect in the flaring work. age. Carry out correct flaring work using the following procedure. 2. After removing drain hose, be sure not to forget mounting drain 1. Measure the distance between the indoor and outdoor units. cap. 2. Cut th

Summary of the content on the page No. 13

898841-UIM-B-0113 5. Carefully bend the bundle (line set, condensate line and cable) to run along the outside wall toward the outdoor unit. Downward slope of wall sleeve will ensure proper condensate drainage. DO NOT FORM THE DRAIN HOSE DO NOT RISE THE DRAIN HOSE INTO THE WAVED SHAPE 50 mm INDOOR UNIT TUBING FLARE NUT PIPES OR MORE FIGURE 24: Connections at Indoor Unit 8. Tighten the flare nut using a wrench. DO NOT PUT THE DRAIN DO NOT PUT THE DRAIN HOSE END HOSE END IN THE INTO WATER DRAINAG

Summary of the content on the page No. 14

898841-UIM-B-0113 BUILDING STRUCTURE Mis-wiring could damage unit or cause communication errors between indoor and outdoor unit. NOTICE • Refer to unit nameplate for minimum circuit ampacity and maxi- mum overcurrent protection size • Local codes may require a disconnect between the indoor and out- door units GROUND • The main system circuit breaker and outdoor unit disconnect LEVEL switch should be sized per local codes and unit requirements • Stranded wire must be used to connect the outdoor u

Summary of the content on the page No. 15

898841-UIM-B-0113 30 & 36 KBTU (208-230V) 208-230V SYSTEMS 115V SYSTEMS SYSTEM ONLY INDOOR UNIT TERMINALS INDOOR UNIT TERMINALS INDOOR UNIT TERMINALS 2 N(1) N(1) 2 N(1) 2 3 3 3 (GND) (GND) (GND) (DATA) (DATA) (NEUTRAL) (DATA) (NEUTRAL) (NEUTRAL) L2 L1 L2 N(1) 2 3 L1 N(1) 23 L1 N N(1) 23 (L1) (GND) (GND) (L1) (L1) (GND) (L2) (NEUTRAL) (L2) OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT TERMINALS TERMINALS TERMINALS TERMINALS FIGURE 32: Outdoor Unit Wiring Terminal Designations REFRIGERANT

Summary of the content on the page No. 16

898841-UIM-B-0113 INSULATION AND TAPING FIELD PROVIDED PROTECTIVE CHANNEL (UTILITY BUNDLE INSIDE) 1. Cover piping joints with pipe cover. 2. For outdoor unit, insulate every pipe including all pipe joints. 3. Using piping tape, apply taping starting from entry of outdoor unit. a. Stop the end of piping tape with tape that has an adhesive agent attached. b. When pipes have to be arranged through above ceiling, closet or where temperature and humidity are high, make sure you wind additional commer

Summary of the content on the page No. 17

898841-UIM-B-0113 Shut-off Suction/Vapor SUCTION/VAPOR Action HOSE WITH 2-WAY SERVICE VALVE 2-way Valve 2-way Service Valve SCHRADER VALVE CLOSED PUSH Evacuating with a REQUIRES FIELD PROVIDED 5/16” FEMALE FLARE TO 1/4” MALE FLAREADAPTER. vacuum pump VALVE CAP OPEN POSITION FLARE CAP CLOSED POSITION FULLY SCHRADER CORE OPEN TO LINE SET SERVICE PORT Outdoor unit running SERVICE PORT CAP TO OUTDOOR UNIT FLARE CAP FULLY ALLEN WRENCH (5MM) OPEN OPEN POSITION Checking pressure CLOSED POISTION TO LI

Summary of the content on the page No. 18

898841-UIM-B-0113 CHECK PLACES FOR FLARE NUT CONNECTIONS (INDOOR UNIT) CHECK PLACES AUTO/STOP FOR OUTDOOR UNIT MANUAL SWITCH FIGURE 40: Leak Test Line Set Connection AUTO SECTION XVIII: TEST OPERATION TEST 1. Check that all tubing and wiring have been properly connected. RUN 2. Check that the gas and liquid side service valves are fully open. STOP GAS LEAK TEST Check the flare nut connections for gas leaks with a gas leak detector CODE SWITCH and/or soapy water. FIGURE 41: Emergency Operatio

Summary of the content on the page No. 19

898841-UIM-B-0113 CLEANING AND MAINTENANCE 1. Remove the healthy filter and clean thoroughly. Make sure you don't use a brush or any hard objects to clean the filter. 2. Make sure you dry the air filter before reinstalling it. SECTION XXII: TYPICAL UNIT WIRING DIAGRAM The indoor unit wiring diagram is located on the inside of the cabinet by the terminal block. It is necessary to remove the front panel from the Fig. A unit to see the diagram. The outdoor unit wiring diagram is located on the und

Summary of the content on the page No. 20

898841-UIM-B-0113 FIGURE 44: 09K & 12K Outdoor Air Conditioners FIGURE 45: 18K & 24K 115V Indoor Air Conditioners 20 Johnson Controls Unitary Products


Alternative user manuals
# User manual Category Download
1 Johnson Controls 13 SEER User manual Air Conditioner 815
2 Johnson Controls 341426-BIM-A-0108 User manual Air Conditioner 167
3 Johnson Controls J15 User manual Air Conditioner 160
4 Johnson Controls Inc.16 User manual Air Conditioner 289
5 Johnson Controls Inc.13 SEER - GCGD User manual Air Conditioner 79
6 Johnson Controls ACPU024 THRU 060 User manual Air Conditioner 35
7 Johnson Controls Inc.16 SEER - CZF User manual Air Conditioner 36
8 Johnson Controls Inc.13 & 14.5 SEER - TCG(D User manual Air Conditioner 27
9 Johnson Controls Inc.20 User manual Air Conditioner 265
10 Johnson Controls Inc.AL6B SERIES User manual Air Conditioner 32
11 Johnson Controls Inc.AC6B User manual Air Conditioner 26
12 Johnson Controls AFFINITY 340968-XIM-A-0108 User manual Air Conditioner 20
13 Johnson Controls Inc.CSV060B-240B User manual Air Conditioner 27
14 Johnson Controls Inc.F) SERIES User manual Air Conditioner 47
15 Johnson Controls Inc.GCGD18 thru 60 User manual Air Conditioner 12
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21