Johnson Controls Inc.F) SERIES user manual

User manual for the device Johnson Controls Inc.F) SERIES

Device: Johnson Controls Inc.F) SERIES
Category: Air Conditioner
Manufacturer: Johnson Controls
Size: 0.52 MB
Added : 1/16/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Johnson Controls Inc.F) SERIES. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Johnson Controls Inc.F) SERIES.

For your convenience

If looking through the Johnson Controls Inc.F) SERIES user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Johnson Controls Inc.F) SERIES on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Johnson Controls Inc.F) SERIES to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Johnson Controls Inc.F) SERIES User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Johnson Controls Inc.F) SERIES but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Johnson Controls Inc.F) SERIES. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION MANUAL
R-410A
OUTDOOR SPLIT-SYSTEM
AIR CONDITIONING
MODELS: 13 & 14.5 SEER -
®
TCG(D,F)/GCGD/TCJ(D,F)/YCJ(D,F) SERIES
1.5 TO 6.3 TONS – 1 & 3 PHASE
LIST OF SECTIONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 ELECTRICAL CONNECTION

Summary of the content on the page No. 2

872678-UIM-C-0213 LIMITATIONS If the unit is to be installed on a hot sun exposed roof or a black-topped ground area, the unit should be raised sufficiently above the roof or The unit should be installed in accordance with all National, State and ground to avoid taking the accumulated layer of hot air into the outdoor Local Safety Codes and the limitations listed below: unit. 1. Limitations for the indoor unit, coil, and appropriate accessories Provide an adequate structural support. must also b

Summary of the content on the page No. 3

872678-UIM-C-0213 GROUND INSTALLATION The unit should be installed on a solid base that is 2” (5.1 cm) above grade and will not shift or settle, causing strain on the refrigerant lines This system uses R-410A refrigerant which operates at higher pres- and possible leaks. Maintain the clearances shown in Figure 1 and sures than R-22. No other refrigerant may be used in this system. install the unit in a level position. The base pad should not come in con- Gauge sets, hoses, refrigerant containers

Summary of the content on the page No. 4

872678-UIM-C-0213 PRECAUTIONS DURING BRAZING OF LINES All outdoor unit and evaporator coil connections are copper-to-copper and should be brazed with a phosphorous-copper alloy material such Do not install any coil in a furnace which is to be operated during as Silfos-5 or equivalent. DO NOT use soft solder. The outdoor units the heating season without attaching the refrigerant lines to the coil. have reusable service valves on both the liquid and vapor connections. The coil is under 30 to 35 ps

Summary of the content on the page No. 5

872678-UIM-C-0213 SECTION IV: ORIFICE INSTALLATION Only 1TVM900 series valves are to be used on this product. 1. Relieve the holding charge by pulling off the rubber cap plug on Failure to install Schrader Valve Core on orifice applications could the suction manifold line of the coil. result in total refrigerant loss of the system! 2. After holding charge is completely discharged, loosen and remove Install Schrader Valve Core and Orifice as follows: the Schrader cap seal. 1. Slide indoor coil ou

Summary of the content on the page No. 6

872678-UIM-C-0213 4. Using the charging chart located on the unit, find the intersection SECTION VII: SYSTEM CHARGE of the outdoor ambient dry bulb and the suction pressure obtained The factory charge in the outdoor unit includes enough charge for the in step 3. This is the recommended suction tube temperature at unit, a 15 ft. (4.6 m) line set, and the smallest indoor coil match-up. the service valve. Some indoor coil matches may require additional charge. See tabular 5. Measure and record the

Summary of the content on the page No. 7

872678-UIM-C-0213 TABLE 2: R-410A Saturation Properties PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE TEMP. °F TEMP. °F TEMP. °F TEMP. °F TEMP. °F PSIG PSIG PSIG PSIG PSIG 45 130 60 170 75 217 90 274 105 341 46 132 61 173 76 221 91 278 106 345 47 135 62 176 77 224 92 282 107 350 48 137 63 179 78 228 93 287 108 355 49 140 64 182 79 232 94 291 109 360 50 142 65 185 80 235 95 295 110 365 51 145 66 188 81 239 96 299 111 370 52 147 67 191 82 243 97 304 112 375 53 150 68 194 83 247 98 308 113 380 54 1

Summary of the content on the page No. 8

872678-UIM-C-0213 FIELD CONNECTIONS CONTROL WIRING 5. Mount the thermostat about 5 ft. above the floor, where it will be exposed to normal room air circulation. Do not place it on an out- 1. Route low voltage wiring into bottom of control box as shown in side wall or where it is exposed to the radiant effect from exposed Figure 6. Make low voltage wiring connections inside the low volt- glass or appliances, drafts from outside doors or supply air grilles. age box per Figures 7 - 11. 6. Route the

Summary of the content on the page No. 9

872678-UIM-C-0213 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. AC 1A Single Stage Air Conditioner – PSC Air Handler ID MODELS AHP SHP MA THERMOSTAT SINGLE STAGE PSC SINGLE STAGE *PP11C70224 AIR AIR HANDLER AIR CONDITIONER CONDITIONER PSC SINGL SINGLE STA E STAGE GE 1 AIR HANDLER CONTROL AI AIR CO R COND NDIT ITI IO ON NE ER R COM C 24 – Volt Common 24 – Volt Common Y/Y2 Y

Summary of the content on the page No. 10

872678-UIM-C-0213 AC 1B Single Stage Air Conditioner – PSC Air Handler ID MODELS AHP SHP MA THERMOSTAT THERMOSTAT *BP11C50124 SINGLE STAGE *BN11C01124 PSC *BN11C00124 AIR *DP11C40124 AIR HANDLER CONDITIONER *DN11C00124 PSC 1 SINGLE STAGE AIR HANDLER CONTROL AIR CONDITIONER C C COM C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common Y/Y2 Y Y Y Second or Full Full Stage Compressor Full Stage Compressor Compressor Contactor Stage Compressor RH RH R 24 – Volt Hot 24 – Volt Hot 24

Summary of the content on the page No. 11

872678-UIM-C-0213 AC 5D Single Stage Air Conditioner – Single Stage PSC Furnace ID MODELS G*(8/9)S GF(8/9) G*9F LF8 L(Y/M)8S TG(8/9)S THERMOSTAT G8C (G/T)GLS SINGLE STAGE SINGLE STAGE *PP11C70224 PSC AIR FURNACE CONDITIONER SINGLE STAGE PSC 1 SINGLE STAGE SINGLE STAGE FURNACE AIR CONDITIONER AIR CONDITIONER C C 24 – Volt Common 24 – Volt Common Y Y/Y2 Y Y Full Stage Compressor Full Stage Compressor Compre Co ssor Co mpressor ntactor RH R 24 – Volt Hot 24 – Volt Hot (Heat XFMR) G G Fan Fan W Ful

Summary of the content on the page No. 12

872678-UIM-C-0213 AC 5E Single Stage Air Conditioner – Single Stage PSC Furnace ID MODELS G*(8/9)S GF(8/9) G*9F LF8 L(Y/M)8S TG(8/9)S THERMOSTAT THERMOSTAT G8C (G/T)GLS *BP11C50124 SINGLE STAGE SINGLE STAGE *BN11C01124 *BN11C00124 PSC AIR *DP11C40124 FURNACE CONDITIONER *DN11C00124 SINGLE STAGE PSC 1 SINGLE STAGE FURNACE AIR CONDITIONER C C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common Y Y Y/Y2 Y Full Stage Compressor Full Stage Compressor Full Stage Compressor Compres

Summary of the content on the page No. 13

872678-UIM-C-0213 3. If the coil needs to be cleaned, use clean water to wash dust, dirt, SECTION IX: INSTRUCTING THE OWNER and debris from outdoor condensing coil. Assist owner with processing warranty cards and/or online registration. Review Owners Guide and provide a copy to the owner and guidance on proper operation and maintenance. Instruct the owner or the opera- NOTICE tor how to start, stop and adjust temperature setting. DO NOT use coil cleaners to clean outdoor condensing coil. clean-

Summary of the content on the page No. 14

872678-UIM-C-0213 SECTION X: WIRING DIAGRAM FIGURE 14: Wiring Diagram - Single Phase 14 Johnson Controls Unitary Products

Summary of the content on the page No. 15

872678-UIM-C-0213 *412217* FIGURE 15: Wiring Diagram - Three Phase 2.5-5 Tons Johnson Controls Unitary Products 15

Summary of the content on the page No. 16

872678-UIM-C-0213 DANGER - SHOCK HAZARD 1 COMPONENTS SHOWN IN DASHED LINES ARE OPTIONAL. TURN OFF ELECTRICAL POWER BEFORE 2 RED WIRE WILL BE REMOVED IF LOW AMBIENT KIT IS SERVICING TO PREVENT POSSIBLE DAMAGE INSTALLED. TO THE EQUIPMENT AND POSSIBLE PERSONAL INJURY. 3 YELLOW WIRE WILL BE REMOVED IF PRESSURE SWITCH KIT IS INSTALLED. CAUTION TO PREVENT ELECTRICAL SHOCK OPEN 4 IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT REMOTE DISCONNECT SO ELECTRICAL MUST BE REPLACED, IT MUST BE REPLACED WI

Summary of the content on the page No. 17

872678-UIM-C-0213 SECTION XI: START UP SHEET Air Conditioning and Heating Start-Up Sheet Print Form Reset Form Proper start-up is critical to customer comfort and equipment longevity Start-Up Date Technician Performing Start-Up Installing Contractor Name Owner Information Name Address City State or Province Zip or Postal Code Equipment Data Upflow Downflow Horizontal Left Horizontal Right Indoor Unit Model # Indoor Unit Serial # Indoor Coil Model # Ind

Summary of the content on the page No. 18

Air Side: System Total External Static Pressure Supply static before indoor coil (in w.c.") Supply static after indoor coil (in w.c.") Return Static (in w.c.") before filter Return Static (in w.c.") after filter (furnace side) Total External Static Pressure Maximum Rated ESP (in w.c.") COOL A B C D ADJUST ECM A B C D Cooling DELAY Indoor A B C D Blower Set-Up X-13 1 2 3 4 5 PSC Low Medium Low Medium Medium High High Return Air: Dry Bulb Wet Bulb Supply Air: Dry Bulb Temperature D


Alternative user manuals
# User manual Category Download
1 Johnson Controls 13 SEER User manual Air Conditioner 815
2 Johnson Controls 341426-BIM-A-0108 User manual Air Conditioner 167
3 Johnson Controls J15 User manual Air Conditioner 160
4 Johnson Controls Inc.16 User manual Air Conditioner 289
5 Johnson Controls Inc.13 SEER - GCGD User manual Air Conditioner 79
6 Johnson Controls ACPU024 THRU 060 User manual Air Conditioner 35
7 Johnson Controls Inc.16 SEER - CZF User manual Air Conditioner 36
8 Johnson Controls Inc.13 & 14.5 SEER - TCG(D User manual Air Conditioner 27
9 Johnson Controls Inc.20 User manual Air Conditioner 265
10 Johnson Controls Inc.22 SEER User manual Air Conditioner 51
11 Johnson Controls Inc.AL6B SERIES User manual Air Conditioner 32
12 Johnson Controls Inc.AC6B User manual Air Conditioner 26
13 Johnson Controls AFFINITY 340968-XIM-A-0108 User manual Air Conditioner 20
14 Johnson Controls Inc.CSV060B-240B User manual Air Conditioner 27
15 Johnson Controls Inc.GCGD18 thru 60 User manual Air Conditioner 12
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21