Tripp Lite PowerVerter APSX6048VR user manual

User manual for the device Tripp Lite PowerVerter APSX6048VR

Device: Tripp Lite PowerVerter APSX6048VR
Category: Welding System
Manufacturer: Tripp Lite
Size: 2.84 MB
Added : 8/9/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Tripp Lite PowerVerter APSX6048VR. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Tripp Lite PowerVerter APSX6048VR.

For your convenience

If looking through the Tripp Lite PowerVerter APSX6048VR user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Tripp Lite PowerVerter APSX6048VR on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Tripp Lite PowerVerter APSX6048VR to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Tripp Lite PowerVerter APSX6048VR User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Tripp Lite PowerVerter APSX6048VR but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Tripp Lite PowerVerter APSX6048VR. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual
®
PowerVerter
APSX6048VR Pure Sine Wave
DC-to-AC Inverter/Charger
Input Output 1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1212
Invert: 48 VDC 208/230V, 50/60 Hz. AC
www.tripplite.com
Charge: 208/230V, 50/60 Hz. AC 48 VDC
Reliable Emergency Backup Power
Congratulations! You’ve purchased the most advanced, feature-rich Inverter/Charger designed as an alternative energy source during utility
power failures. Tripp Lite APS Inverter/Chargers keep your equipm

Summary of the content on the page No. 2

Important Safety Instructions SAVE THESE INSTRUCTIONS! This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite Inverter/Chargers. Location Warnings • Install your Inverter/Charger (whether for a mobile or stationary application) in a location or compartment that minimizes exposure to heat, dust, direct sunlight and moisture. • Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Floo

Summary of the content on the page No. 3

Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to maximize their use. Configuration DIP Switches: optimize Inverter/Charger Knockouts for AC Input/Output Conduits 1 7 operation depending on your application. See Configuration 8 Remote Control Module Connector: allows remote monitoring Section for setting instructions. and control with an optional module (Tripp Lite model Operating Mode Rocker Switch: controls Inverter/Charger

Summary of the content on the page No. 4

Operation OPERATION LOAD Red Indicator: This red light will Switch Modes LINE INV ILLUMINATE CONTINUOUSLY whenever the After configuring, mounting and connecting your Inverter/Charger, you LOAD inverter is functioning and the power demanded by are able to operate it by switching between the following operating connected appliances and equipment exceeds 100% modes as appropriate to your situation: of load capacity. The light will FLASH to alert you AUTO/REMOTE: Switch to this mode when you when t

Summary of the content on the page No. 5

Configuration Set Configuration DIP Switches Using a small tool, set the Configuration DIP Switches (located on the front panel of your unit, see diagram) to optimize Inverter/Charger operation depending on your application. Warning: Make sure the unit is turned OFF before changing DIP Switch settings. BATTERY OPERATION HIGH LINE MED INV REMOTE LOW CONTROL LOAD CONFIGURATION DIP SWITCHES (SEE MANUAL OR TOP OF UNIT FOR INSTRUCTIONS) 12 3 4 5 6 7 8 9101112 Not Used 1 2 Select Line Connect Relay T

Summary of the content on the page No. 6

(continued) Configuration Switch #4 Set for 230 VAC Operation (#4 Down) Select Low AC Input Voltage Point for Select High AC Input Voltage Point for 10 11 270 V 180 V Switching to Battery - OPTIONAL* Switching to Battery - OPTIONAL* Voltage Switch Position Voltage Switch Position 180 VAC Up 270 VAC Up 9 10 11 12 260 V 9 10 11 12 170 V 170 VAC Down (factory setting) 260 VAC Down (factory setting) Switch #4 Set for 208 VAC Operation (#4 Up) Select Low AC Input Voltage Point Select High A

Summary of the content on the page No. 7

Battery Selection Select Battery Type Select “Deep Cycle” batteries to enjoy optimum performance from your Inverter/Charger. Batteries of either Wet-Cell (vented) or Gel-Cell /Absorbed Glass Mat (sealed) construction are ideal. 6-volt “golf cart,” Marine Deep-Cycle or 8D Deep-Cycle batteries are also acceptable. You must set the Inverter/Charger’s Battery Type DIP Switch (see Configuration section for more information) to match the type of batteries you connect or your batteries may be degraded

Summary of the content on the page No. 8

Battery Connection Connect your Inverter/Charger to your batteries using the following procedures: • Connect DC Wiring: Though your for brief periods of time. Heavier gauge the Main Ground Lug on your specific Inverter/Charger is a cabling should be used when continuously Inverter/Charger model. All installations high-efficiency operating heavy draw equipment under these must comply with national and local codes converter of conditions. Tighten your Inverter/Charger and ordinances. electricity,

Summary of the content on the page No. 9

AC Input/Output Connection To avoid overloading your Inverter/Charger, be sure to match the power requirements of the equipment you plan to run at any one time (add their total watts) with the output wattage capacity of your Inverter/Charger model. When figuring the power requirements of your equipment, do not confuse “continuous” wattage with “peak” wattage ratings. Most electric motors require extra power at start-up (“peak” wattage) than required to run continuously after start-up, sometimes

Summary of the content on the page No. 10

Troubleshooting Try these remedies for common Inverter/Charger problems before calling for assistance. Call Tripp Lite Customer Service before returning your unit for service. SYMPTOM PROBLEMS CORRECTIONS No AC Output Unit is not properly connected to utility power. Connect unit to utility power. (All Indicator Lights Are OFF) Operating Mode Switch is set to “OFF” and Set Operating Mode Switch to “AUTO/REMOTE” or “CHARGE ONLY.” AC input is present. This is normal when the Operating Mode Switch N

Summary of the content on the page No. 11

Specifications MODEL NUMBER: APSX6048VR † Minimum Recommended Cable Sizing AC Input Connection: Hardwire Use in conjunction with DC wiring connection instructions in the Battery Connection section. INVERTER The Inverter/Charger includes a Battery Charge Conserver (Load Sense) Control which saves † NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance). Cable length is the sum of the positive cable length and the negative cable length

Summary of the content on the page No. 12

Manual del Propietario ® PowerVerter Inversor/Cargador CD a CA de Autentica Onda Sinusoidal APSX6048VR Entrada Salida 1111 W. 35th Street, Chicago, IL 60609 USA Inversor: 48 VCD 208/230V, 50/60 Hz. CA Soporte a Clientes: (773) 869-1212 Cargador: 208/230V, 50/60 Hz. CA 48 VCD www.tripplite.com Confiable Energía de Respaldo de Emergencia ¡Felicitaciones! Ha adquirido el Inversor/Cargador más avanzado, lleno de opciones, diseñado como una fuente alternativa de energía durante fallas en la energía d

Summary of the content on the page No. 13

Instrucciones de Seguridad Importantes ¡CONSERVE ESTAS INSTRUCCIONES! Este manual contiene instrucciones y advertencias importantes que deberán seguirse durante la instalación, operación y almacenaje de todos los Inversores/Cargadores de Tripp Lite. Advertencias para la Ubicación de su Equipo • Instale su Inversor/Cargador (Ya sea para aplicaciones móviles o fijas) en una ubicación o compartimiento que minimice la exposición al calor, polvo o a la luz directa y la humedad. • Aunque su Inversor

Summary of the content on the page No. 14

Identificación de Características Identifique las características Premium de su modelo especifico y localice las instrucciones de como maximizar sus usos. Interruptores DIP de Configuración: Optimice la operación Accesos para Cables de Entrada/Salida CA 1 7 del Inversor/Cargador dependiendo de su aplicación. Vea la Conector para el Módulo de control Remoto: Permite el 8 sección configuración para instrucciones de ajuste de monitoreo y control remoto con un módulo opcional (Tripp Lite parámetros.

Summary of the content on the page No. 15

Operación OPERATION INV (Invirtiendo) Indicador Amarillo: Esta luz se Modos del Interruptor LINE INV ILUMINARA CONTINUAMENTE cada vez que el Después de configurar, montar y conectar su Inversor/Cargador, LOAD equipo conectado esté recibiendo energía CA Usted puede operarlo conmutando entre los siguientes modos de suministrada por la batería. (en ausencia de una fuente operación conforme a su situación. del Servicio Público/Generador o en situaciones de AUTO/REMOTE [Auto/Remoto]: Cambie a este s

Summary of the content on the page No. 16

Configuración Ajuste los Interruptores de Configuración DIP Usando un herramienta pequeña ajustes los interruptores de configuración DIP (Localizados en el panel frontal de la unidad. Vea el diagrama) para optimizar el la operación del Inversor/Cargador dependiendo de su aplicación. Advertencia: Asegúrese de que la unidad esté apagada antes de cambiar los valores de los interruptores DIP. BATTERY OPERATION HIGH LINE MED INV REMOTE LOW CONTROL LOAD CONFIGURATION DIP SWITCHES (SEE MANUAL OR TOP O

Summary of the content on the page No. 17

(continuación) Configuración Interruptor # 4 Ajustado para operar a 230 VAC (# 4 Abajo) Seleccione un Punto de Voltaje de Entrada Seleccione un Punto de Voltaje de Entrada CA 10 11 270 V 180 V CA Bajo para Cambiar a la Batería Alto para Cambiar a la Batería - OPCIONAL* - OPCIONAL* Voltaje Posición del Interruptor Voltaje Posición del Interruptor 270 VAC Arriba 180 VAC Arriba 9 10 11 12 260 V 170 V 9 10 11 12 260 VAC Abajo 170 VAC Abajo (Configuración de Fábrica) (Configuración de Fá

Summary of the content on the page No. 18

Selección de la Batería Seleccione el Tipo de Batería Seleccione baterías “Deep Cycle” para obtener el rendimiento óptimo de su Inversor/Cargador. Las baterías, ya sean de Celda Húmeda (ventiladas) o de celdas de Gel/ Absorbed Glass Mat [AGM] (selladas) son ideales. Las baterías de 6-volt “golf cart,” [Carro de Golf], Marine Deep-Cycle [Deep Cycle Marinas] o Deep Cycle 8D, son también aceptables. Debe colocar el interruptor DIP del tipo de Baterías de su Inversor/Cargador (Vea la sección de conf

Summary of the content on the page No. 19

Conexión de la Batería Conecte Su Inversor/Cargador a sus baterías usando los siguientes procedimientos: • Conecte los cables CD: Aunque su breves períodos de tiempo. Se deben usar localizar su Poste Principal a Tierra en su Inversor/Cargador cables de más grueso calibre cuando se Inversor/Cargador específico. Todas las es un eficiente opere en forma continua equipos de alto instalaciones deben cumplir con los convertidor de consumo bajo estas condiciones. Apriete las reglamentos, ordenanzas y

Summary of the content on the page No. 20

Conexión de Entrada/Salida CA Para evitar sobre cargar el Inversor/Cargador, asegúrese de empatar los requerimientos de energía del equipo que planea operar en cualquier momento dado (Sume sus watts totales) con la capacidad de salida de su modelo de Inversor/Cargador. Cuando estime los requerimientos de energía de su equipo no confunda wattaje “continuo” con “Niveles Momentáneos Máximos” de wattaje. La mayoría de los motores eléctricos requieren al momento de arrancar más energía-extra (“Nivele


Alternative user manuals
# User manual Category Download
1 Tripp Lite PowerVerter APSX6048VR User manual Power Supply 7
2 Tripp Lite 3-Phase 20kVA User manual Welding System 27
3 Tripp Lite APINT Series User manual Welding System 2
4 Tripp Lite APSINT612 User manual Welding System 15
5 Tripp Lite 30kVA User manual Welding System 16
6 Tripp Lite 450-1400VA User manual Welding System 1
7 Tripp Lite PV500FC User manual Welding System 5
8 Tripp Lite APS INT 512 User manual Welding System 16
9 Tripp Lite PowerVerter DC-to-AC Inverter/Charger APSX700HF User manual Welding System 2
10 Tripp Lite POWERVERTER 200712159 93-2768 RV User manual Welding System 1
11 Tripp Lite APSX6048VRNET User manual Welding System 18
12 Tripp Lite APSX User manual Welding System 4
13 Tripp Lite User manual Welding System 1
14 Tripp Lite 1250-3000 VA User manual Welding System 10
15 Sony 6 User manual Welding System 0
16 ADTRAN NT1 T400 User manual Welding System 1
17 AEG 2000 User manual Welding System 2
18 AEG PV 2000 User manual Welding System 8
19 Agilent Technologies AC Power Solutions 6814B User manual Welding System 8