Our goal is to provide you with a quick access to the content of the user manual for Honeywell IAQ. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell IAQ.

For your convenience

If looking through the Honeywell IAQ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell IAQ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell IAQ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell IAQ User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell IAQ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell IAQ. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation
Guide
VisionPRO® IAQ
Touch-screen Programmable Thermostat
For up to 4 Heat/2 Cool systems with Honeywell THM5421C or equivalent.
Must be installed by a trained, experienced technician. Read these instructions
carefully. Failure to follow these instructions can damage the product or cause a
hazardous condition.
CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage.
Disconnect power before beginning installation.
MERCURY NOTICE: If this product is replacing a

Summary of the content on the page No. 2

Installation Guide TUE Installer setup TUE Inside 1 Press S Y S T E M 2 Press and hold for 5 seconds Press D O N E to save & exit 70 3 Change settings (see p. 2-6) SYSTEM TUE HEAT 0120 20 FAN Inside 6:00aM TUE AUTO 70 DONE Inside SYSTEM DONE CANCEL 70 HEAT Function Setting 6:00aM 6 SCHED HOLD 0120 20 DONE Press s t to change Installer setup Setup function Settings & options (factory default in bold) 0110 Zone number 0 Not zoned 1–9 Zone number 0120 Year 20 (2000-2099) (first two digits) 21 (21

Summary of the content on the page No. 3

VisionPRO® IAQ Installer setup Setup function Settings & options (factory default in bold) 0210 External fossil 1 External fossil fuel kit controls backup heat fuel kit 0 Thermostat controls backup heat (outdoor sensor required) 0220 Stage 1 compressor E Auto Discover ** 1cycle rate [Other options: 1 to CPH] 0230 Stage 2 compressor E Auto Discover ** cycle rate [Other options: 1 to 6 CPH] 0240 Stage 1 heat cycle E Auto Discover ** rate (CPH= cycles [Other options: 1 to 12 CPH] per hour) 0

Summary of the content on the page No. 4

Installation Guide Installer setup Setup function Settings & options (factory default in bold) 0372 Indoor humidifica- E Auto Discover ** tion control 0 Off 1 Humidify (no frost protection) 3 Humidify (with frost protection) 0374 Humidifier fan action 0 Humidify only while fan or heat is on 1 Humidify forces fan on 2 Humidify only when heat is on 3 Humidifier operates independent of fan 0379 Dehumidification 0 No dehumidification control 1 Dehumidify with air conditioner control 3 Whole house

Summary of the content on the page No. 5

VisionPRO® IAQ Installer setup Setup function Settings & options (factory default in bold) 0502 Furnace filter 0 Timer counts Heat & Cool run time 1 Timer counts Cool run time only alert options 0510 Humidifier pad E Auto Discover ** change alert * 0 Off 1 90 calendar days or 30 days run time 2 180 calendar days or 60 days run time 3 365 calendar days or 90 days run time 0520 UV lamp change E Auto Discover ** alert 0 Off 1 365 calendar days (1 year) 2 730 calendar days (2 years) 0530 Adapti

Summary of the content on the page No. 6

Installation Guide Special function Auto Discover: Setup functions set to “E” (Auto Discover) will be configured automatically, based on information sent from connected equipment. When using Auto Discover, verify that the discovered value is correct. If it is not, the equipment is not communicating the information, and you must change settings manually. Adaptive Intelligent Recovery (Setup Function 0530): Allows the thermostat to “learn” how long the furnace and air conditioner take to reach

Summary of the content on the page No. 7

VisionPRO® IAQ TUE Installer system test Inside Test System During installer setup, press t 70 number status repeatedly until “Test” appears 1 0120 20 DONE TEST 0 DONE Press s t to Press s t to Press D O N E to terminate testing select test change status System test System status Other messages 1 Cooling 0 Off P Ventilation meets ASHRAE 62.2 system 1 Test cooling stage 1 standard (Function 0404) 2 Test cooling stages 1 & 2 F Ventilation does not meet ASHRAE 2 Fan system 0 Fan off 62.2

Summary of the content on the page No. 8

Installation Guide Error codes 027 Faulty thermostat (must be replaced) 035 Duplicate thermostat zone detected 036 Duplicate UV timer 037 Duplicate filter timer 038 Duplicate humidifier pad timer 039 Duplicate indoor humidity sensor 040 Compressor should be running but it is not 050 Duplicate outdoor temperature sensor 052 Faulty post-coil air discharge sensor 053 Faulty outdoor temperature sensor 054 Faulty indoor humidity sensor 089 Heating/cooling equipment is missing 090 Data interface is co

Summary of the content on the page No. 9

Guide d’installation VisionPRO® IAQ Thermostat programmable à écran tactile Pour installations comportant 4 circuits de chauffage/2 circuits de climatisation avec Honeywell THM5421C ou équivalent. Il est impératif de faire réaliser l’installation par un technicien chevronné. Lisez attentivement les présentes consignes. La non observation de celles-ci risque d’endommager le produit ou de présenter des dangers. MISE EN GARDE : RISQUE DE CHOC ÉLECTRIQUE. Peut causer un choc électrique ou endom

Summary of the content on the page No. 10

Installation Guide Configuration TUE TUE 1 Appuyer sur 2 Appuyez 5 secondes Appuyez D O N E pour Inside S Y S T E M sauvegarder et quitter 3 Changez les arrangements 70 (voir p. 10-14) SYSTEM TUE HEAT 0120 20 FAN Inside 6:00 TUE aM AUTO 70 DONE Inside SYSTEM DONE CANCEL HEAT 70 Fonction Arrangement 6:00aM 6 SCHED HOLD 0120 20 DONE Appuyez s t pour changer Configuration Fonctions Paramètres et choix (défaut usine en gras) 0110 Nombre de zones 0 Aucune 1–9 Nombre de zones 0120 Année (deux 20 (

Summary of the content on the page No. 11

VisionPRO® IAQ Configuration Fonctions Paramètres et choix (défaut usine en gras) 0200 Chauffage auxiliaire E Auto Discover (arrangement automatique) ** 0 Chauffage de secours électrique 1 Chauffage de secours combustible fossile 0210 Disp. externe de 1 External fossil fuel kit controls backup heat combustible fossile 0 Commande le chauffage de secours (capteur extérieur requis) 0220 Cycle du compres- E Auto Discover (arrangement automatique) ** seur de étage 1 [Autres choix : 1 à 6 cycles/

Summary of the content on the page No. 12

Installation Guide Configuration Fonctions Paramètres et choix (défaut usine en gras) 1 Sonde interne dans le thermostat 0370 Sonde d'intérieur d'humidité 0 Les sondes ont neutralisé E Auto Discover (arrangement automatique) ** 0372 Commande E Auto Discover (arrangement automatique) ** d'humidification 0 Aucun 1 Humidifiez (aucun antigel) 3 Humidifiez (avec antigel) 0 Humidifiez seulement quand le ventilateur ou la chaleur est activ 0374 Action de ventilateur d'humidificateur 1 L'humidifica

Summary of the content on the page No. 13

VisionPRO® IAQ Configuration Fonctions Paramètres et choix (défaut usine en gras) 0500 Rappel de filtre de E Auto Discover (arrangement automatique) ** four à changer 0 Arrêt 7 270 jours de fonctionnement 1 10 jours de fonctionnement 8 365 jours de fonctionnement 2 30 jours de fonctionnement 9 30 jours de calendrier 3 60 jours de fonctionnement 10 60 jours de calendrier 4 90 jours de fonctionnement 11 90 jours de calendrier 5 120 jours de fonctionnement 12 120 jours de calendrier 6 180 jours d

Summary of the content on the page No. 14

Installation Guide Configuration Fonctions Paramètres et choix (défaut usine en gras) 0 Le thermostat affiche le humidité réelle de la pièce 0701 Écart de l’affichage de humidité [Autres choix : -5% à +5%] 0 Pas de rétablissement 0710 RÉTABLISSEMENT 1 Remettre les choix d’installation et le programme au défaut d’usine (seuls les réglages de date et d’heure sont conservés) Fonctions spéciales Auto Discover: Les fonctions de figuration réglées à « E » (auto-découverte) seront configurées auto

Summary of the content on the page No. 15

VisionPRO® IAQ TUE Essai du système Inside Pendant la configuration d’installation, Numéro du test État de l’installation appuyez plusieurs fois sur t jusqu’à ce 70 que « Test » apparaisse. 1 0120 20 TEST 0 DONE Appuyez s t pour sélectionner un test DONE Appuyez s t pour modifier l’état Appuyez D O N E pour terminer les essais Essai de État de l’installation l’installation D'autres messages 0 Arrêt 1 Installation de P La ventilation est conforme climatisation 1 Essai de refroidissement

Summary of the content on the page No. 16

Installation Guide Codes d'erreur 027 Le thermostat est défectueux (doit être remplacé) 035 Détection de deux zones de thermostat 036 Deux temporisateurs UV ont détecté 037 Deux temporisateurs de filtre ont détecté 038 Deux temporisateurs d'humidificateur ont détecté 039 Deux senseurs d'humidité ont détecté 040 Le compresseur devrait être activé mais il n'est pas 050 Deux sondes de température extérieures 052 La sonde de décharge d'air est défectueuse 053 La sonde de température extérieure est d

Summary of the content on the page No. 17

Guía de instalación VisionPRO® IAQ Termostato programable sensible al tacto Para hasta 4 sistemas de calefacción/2 de refrigeración con Honeywell THM5421C o equivalente. Debe instalarlo un técnico capacitado y con experiencia. Lea atentamente estas instrucciones. Si las ignora, podría dañarse el producto o generarse condiciones de peligro. PRECAUCIÓN: RIESGO ELÉCTRICO. Puede ocasionar descargas eléctricas o dañar el equipo. Desconéctelo de la fuente de energía antes de comenzar la instalación

Summary of the content on the page No. 18

Installation Guide Configuración TUE TUE Inside 2 Oprima 5 segundos 1 Presione S Y S T E M Oprima D O N E para salir y (sistema). guardar los ajustes. 70 3 Cambie los ajustes (vea p. 18-22) SYSTEM TUE HEAT 0120 20 FAN Inside aM 6:00 TUE AUTO 70 DONE Inside SYSTEM DONE CANCEL HEAT 70 Función Ajuste 6:00aM 6 SCHED HOLD 0120 20 DONE Oprima s t para cambiar Configuración Función Ajustes y opciones (configuración de fábrica en negritas) 0 Sin división de zona 0110 Número de zona 1–9 Número de zon

Summary of the content on the page No. 19

VisionPRO® IAQ Configuración Función Ajustes y opciones (configuración de fábrica en negritas) 0200 Calor de reserva E Auto Discover (arrangement automatique) ** (Aux & EmHeat) 0 Calefacción eléctrica de respaldo 1 Calefacción de combustible fósil de respaldo 1 Juego de combustible fósil externo controla la calefacción de 0210 Juego para combus- tible fósil externo respaldo 0 Termostato controla la calefacción de respaldo (necesita sensor exterior) 0220 Ciclo del compresor E Auto Discover

Summary of the content on the page No. 20

Installation Guide Configuración Función Ajustes y opciones (configuración de fábrica en negritas) 0370 Sensor interior de 1 Sensor interno en termóstato 0 Sensores inhabilitados la humedad E Auto Discover (ajuste automático) ** 0372 Control interior de E Auto Discover (ajuste automático) ** la humectación 0 Apagado 1 Humedezca (ninguna protección de helada) 3 Humedezca (con la protección de helada) 0374 Acción del ventilador 0 Humedezca solamente mientras que el ventilador o el calor está e


Alternative user manuals
# User manual Category Download
1 Honeywell 191108AJ User manual Thermostat 629
2 Honeywell 42011076-003 User manual Thermostat 204
3 Honeywell 69-0786-2 User manual Thermostat 57
4 Honeywell 69-1776EFS-01 User manual Thermostat 56
5 Honeywell 72838 User manual Thermostat 42
6 Honeywell 69-2485EFS-03 TH8320ZW1000 User manual Thermostat 48
7 Honeywell 5-2-DAY DELUXE RTH6300B User manual Thermostat 50
8 Honeywell 7300 User manual Thermostat 20
9 Honeywell 69-1490 User manual Thermostat 10
10 Honeywell 8000 User manual Thermostat 90
11 Honeywell 8160 User manual Thermostat 9
12 Honeywell 9820i User manual Thermostat 8
13 Honeywell 8162 User manual Thermostat 3
14 Honeywell 7351F User manual Thermostat 30
15 Honeywell AC-220-7 User manual Thermostat 3
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2