York B3CH 048 and 060 user manual

User manual for the device York B3CH 048 and 060

Device: York B3CH 048 and 060
Category: Heat Pump
Manufacturer: York
Size: 0.25 MB
Added : 9/25/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York B3CH 048 and 060. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York B3CH 048 and 060.

For your convenience

If looking through the York B3CH 048 and 060 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York B3CH 048 and 060 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York B3CH 048 and 060 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York B3CH 048 and 060 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York B3CH 048 and 060 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York B3CH 048 and 060. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


SUNLINE 2000
SINGLE PACKAGE HEAT PUMPS
INSTALLATION INSTRUCTION 035-12984-001-A-0204
Supersedes: 511.13-N1YI (900)/035-12984-000
MODELS B3CH 048 AND 060
(WORLD 50 HZ)
GENERAL
YORK Model BCH units are single package heat pumps
• 530.18-N7.1V -Electric Heater Accessory
designed for outdoor installation on a rooftop or a slab.
• 530.18-N7.2V -Fuse Block Accessory
Supplemental electric heaters are available as field-installed
accessories. The units are manufactured under ISO 9002
Renewal Parts:

Summary of the content on the page No. 2

035-12984-001-A-0204 TABLE OF CONTENTS General................................................................................1 MAINTENANCE Inspection ............................................................................1 Normal Maintenance .........................................................14 Reference............................................................................1 Approvals ............................................................................1 TABLES Nomenclatu

Summary of the content on the page No. 3

035-12984-001-A-0204 INSTALLATION RIGGING AND HANDLING Exercise care when moving the unit. Do not remove any LIMITATIONS packaging until the unit is near the place of installation. Rig the These units must be installed in accordance with national and unit by attaching chain or cable slings to the lifting holes local or municiple safety codes: Refer to Table 1 for Unit provided in the base rails. Spreaders, whose length exceeds Application Data. the largest dimension across the unit, MUST be used

Summary of the content on the page No. 4

035-12984-001-A-0204 size and type. Dirty filters reduce the capacity of the unit and After this unit is installed, back out the compressor bolts until result in frosted coils or safety shutdown. Minimum filter area the sleeve clears the top grommet. and required sizes are shown in Table 3. CAUTION: Do Not loosen compressor mounting bolts. CONDENSATE DRAIN THERMOSTAT Plumbing must conform to local codes. Use a sealing compound on male pipe threads. Install a condensate drain The room thermostat

Summary of the content on the page No. 5

035-12984-001-A-0204 TABLE 2 - AIR FLOW LIMITATIONS NOMINAL UNIT MODEL SIZE, NOMINAL TONS HEATER 45 VOLTAGE SIZE MINIMUM SUPPLY AIR CFM KW 7 1,300 1,600 10 1,300 1,600 15 380/415-3+N-50 1,300 1,600 20 1,300 1,600 30 – 1,600 CONTROL WIRING 1 Typical 24-volt thermostat with subbase -2ET03700424 for manual changeover. 2 Only required on units with supplemental electric heat. TO REMOTE SENSOR 2ET04701324 IF USED 1 Typical Electronic programmable thermostat 2ET04701124 with subbase for either manual

Summary of the content on the page No. 6

035-12984-001-A-0204 heater accessory installation instruction for the heater electrical data. flange surface on each side plate. Extend gasketing 6mm ( 1 in.) beyond top and bottom of each flange to insure ade- The minimum air flow limitations across these heaters are 4 quate corner sealing. Secure this assembly to the unit back listed in Table 2. panel (upper right hand corner). First, remove screw (C) on OPTIONAL ECONOMIZER RAIN HOOD unit top cover. Then slip flange of hood cover in under fla

Summary of the content on the page No. 7

035-12984-001-A-0204 FIG. 5 - ENTHALPY SET POINT ADJUSTMENT TABLE 3 - PHYSICAL DATA BCH WEIGHTS (kg/lbs) MODELS 048 060 048 270 / 595 CENTRIFUGAL BLOWER (Dia. x 305 x254 305 x 254 Basic Unit SUPPLY AIR Wd.,mm/in.) 12 x 10 12 x 10 060 281 / 620 BLOWER FAN MOTOR HP (Direct-Drive Units) 0.75 NA OPTIONS / ACCESSORIES FAN MOTOR HP (Belt-Drive Units) NA 1.5 ROWS DEEP 3 3 5 - 7 kW 8.2 / 18 INDOOR FINS PER 25mm (1 inch) 15 15 Electric Heat COIL 2 2 10 - 15 kW 10.4 / 23 FACE AREA (m /ft ) 0.47 / 5.1 0.47

Summary of the content on the page No. 8

035-12984-001-A-0204 OUTDOOR COIL (Direct-Drive Units) 829 32-5/8" 2090 82-1/4" RETURN AIR 64 1140 2-1/2 SUPPLY AIR 44-7/8" OUTDOOR AIR 292 11-1/2" OUTDOOR AIR (Economizer) 445 17-1/2" All dimensions are in millimeters and 137 inches. They are subject to change without 5-3/8 165 6-1/2" notice. Certified dimensions will be pro- 445 17-1/2" vided upon request. 171 200 6-3/4" 7-7/8" 206 8-1/8" 213 8-3/8" UTILITIES ENTRY DATA KNOCKOUT HOLE SIZE USED FOR (DIA.) Control Wiring A 5mm (7/8") * (Side or

Summary of the content on the page No. 9

035-12984-001-A-0204 DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. 292 For bottom duct applications; 1 “ 2 1. Remove the side supply air duct cover to gain ac- cess to the bottom supply air knockout panel. 76 3" 2. Remove and discard the bottom knockout panel. 3. Replace the side duct cover. 437 1 292 4. With filter section acce

Summary of the content on the page No. 10

035-12984-001-A-0204 TABLE 4 - SUPPLY AIR PERFORMANCE - BCH048 380 / 415 VOLTS - SIDE DUCT APPLICATIONS Available External Static Pressure - Pa* MOTOR MODEL SPEED 3 3 3 3 3 3 3 3 3 m /s Watts m /s Watts m /s Watts m /s Watts m /s Watts m /s Watts m /s Watts m /s Watts m /s Watts HI - - - - 0.94 1010 0.92 975 0.90 945 0.87 910 0.83 825 0.78 825 0.72 775 048 MED 0.85 910 0.84 880 0.82 850 0.80 825 0.79 800 0.76 775 0.74 740 0.70 700 0.66 660 LOW 0.77 810 0.76 780 0.75 760 0.73 740 0.73 730 0.71 71

Summary of the content on the page No. 11

035-12984-001-A-0204 TABLE 8 - ELECTRICAL DATA - Basic Unit VOLTAGE SUPPLY MAX. MAX. MIN. COMPRESSOR OUTDOOR TOTAL LIMITATIONS AIR FUSE HACR WIRE MODEL FAN UNIT POWER SUPPLY BLOWER SIZE, BREAKER SIZE, BCH MOTOR, AMPACITY, MOTOR, (SEE NOTE 1) SIZE, AWG MIN. MAX. RLA LRA FLA AMPS FLA AMPS AMPS (SEE NOTE 2) 2 048 380/415-3+N-50 342 457 9.6 66 1.8 4.0 18.3 25 25 10 (6MM ) 2 060 380/415-3+N-50 342 457 10.0 75 1.8 2.6 16.9 25 25 10 (6MM ) NOTES: 1. Dual element, time delay type. 2. Based on 75°C copp

Summary of the content on the page No. 12

035-12984-001-A-0204 OPERATION screw fully clockwise and then energize and de-energize 250 terminals “R” to “G”. With terminals “R” to “G” energized, turn the minimum position screw counterclockwise until the desired minimum position has been attained. 200 T3 - 110 Minute Setting (Factory Set Point) 11. Replace the filter section access panel. 150 COOLING SYSTEM T2 - 80 Minute Setting The unit has an air-cooled condenser and is factory-charged 100 with Refrigerant-22. The compressor is hermetica

Summary of the content on the page No. 13

035-12984-001-A-0204 During troubleshooting, the defrost time can be reduced to 20 seconds by shorting out the SW1 test pegs on the module. The 1 3 pegs are 13mm ( in.) long, 1mm ( in.) apart and are 2 mounted on a white base. See Figure 8. LOCKOUT CONTROL Any one of four conditions will put the system into a lock-out condition during the heating or cooling mode: 1. The discharge line temperature reaches 124°C (255°F) (102°C [215°F] reset) or, 2. The discharge pressure reaches 2770 kPa (398 PSIG

Summary of the content on the page No. 14

035-12984-001-A-0204 3. Using an inclined manometer, determine the pressure drop across a dry indoor coil. Since the moisture on an indoor coil may vary greatly, measuring the pressure drop across a wet coil under field conditions would be inaccurate. To ensure a dry coil, the compressors should be de-energized while the test is being run. 4. Knowing the pressure drop across a dry coil, the actual airflow through the unit can be determined from the curve in Figure 11. WARNING:Failure to properly

Summary of the content on the page No. 15

035-12984-001-A-0204 Unitary Products Group 15

Summary of the content on the page No. 16

Unitary Products Group 5005 York Drive, Norman, Ok 73069 Subject to change without notice. Printed in U.S.A. Supersedes: 511.13-N1YI (900) / 035-12984-000 035-12984-001-A-0204 Copyright by York International Corporation 2004. All Rights Reserved.


Alternative user manuals
# User manual Category Download
1 York 060 User manual Heat Pump 12
2 York 161038-YUM-A-1205 User manual Heat Pump 3
3 York 2S User manual Heat Pump 3
4 York 8T User manual Heat Pump 94
5 York 3S User manual Heat Pump 2
6 York 090 User manual Heat Pump 1
7 York AHP18 THRU 60 User manual Heat Pump 1
8 York B1HP024 THRU 048 User manual Heat Pump 0
9 York AFFINITY YZB User manual Heat Pump 0
10 York BQ 060 User manual Heat Pump 1
11 York BQ 048 User manual Heat Pump 3
12 York B1HH018 User manual Heat Pump 1
13 York BP 036 User manual Heat Pump 4
14 York BQ 036 User manual Heat Pump 1
15 York E*BD-F018 THRU 060 User manual Heat Pump 2
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5