Enviro EG40 BV user manual

User manual for the device Enviro EG40 BV

Device: Enviro EG40 BV
Category: Indoor Fireplace
Manufacturer: Enviro
Size: 1.46 MB
Added : 5/9/2013
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Enviro EG40 BV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Enviro EG40 BV.

For your convenience

If looking through the Enviro EG40 BV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Enviro EG40 BV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Enviro EG40 BV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Enviro EG40 BV User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Enviro EG40 BV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Enviro EG40 BV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
EG40 BV
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
WHAT TO DO IF YOU SMELL GAS
• Open windows/Extinguish any open flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use any phone in your
building.
• Immediately call your gas supplier from a neighbour’s phone.
Follow the gas supplier’s in

Summary of the content on the page No. 2

Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, if the pilot or pilot and in accordance with their instructions. Carefully read all burners have gone out on their own, open the the instructions in this manual first. Consult the building glass door and wait 5 minutes to air out before authority having jurisdiction to determine the need for a

Summary of the content on the page No. 3

Table of Contents Safety Precautions..........................................................................................2 Table of Contents...........................................................................................3 Codes And Approvals......................................................................................4 Specifications.................................................................................................5 Dimensions................................

Summary of the content on the page No. 4

Codes And Approvals BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimney liner kit. This appliance has been tested and approved for installations from 0 feet to 2000 feet (610 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas

Summary of the content on the page No. 5

Specifications WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. DIMENSIONS: � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �� � � � � � � � � � � � Figure 1: EG40 Exterior Dimensions. CLEARANCES TO COMBUSTIBLES: A. Sidewall to unit 12 inches (30.5 cm) B. Backwall to unit 4 inches (10.2 cm) � � C. Corner to unit 2 inches

Summary of the content on the page No. 6

Initial Installation QUALIFIED INSTALLERS ONLY VENTING: This model must have a vent opening in the rear of the unit. Confirm this and also check that the label on the right side panel door states “Vented Room Heater”. WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the room. The draft hood located in the same atmospheric pressure zone as the combustion air inlet to the appliance. It is also designed to draw room air for proper heat circu

Summary of the content on the page No. 7

Initial Installation QUALIFIED INSTALLERS ONLY TERMINATION: � � � � � � � � � � � � The bottom of the vent cap shall extend at � � � � � � � � � � � � � � � least 2 feet (0.61 m) above the highest point � � � � � � � � � � � � � � � � � of the roof where it passes through and at � � � � � � � � � � � � � � � � � � � � � � least 2 feet (0.61 m) higher than any portion � � � � � � � of the roof within a horizontal distance of 10 � � � � � � � � � � feet (3.1 m). � � � � � � � See vent manufa

Summary of the content on the page No. 8

Initial Installation QUALIFIED INSTALLERS ONLY STRAIGHT VERTICAL INSTALLATION: This basic venting configuration shown are rough guidelines only. Follow national and local codes for other installation options. For the best venting performance, we recommend a total vent height in the range of 10 feet (3.0 m) to 30 feet (9.1 m). The total horizontal length depends on the number of elbows used; a 90° elbow accounts for 5 feet (1.5 m) of the horizontal run. The venting should never slope down,

Summary of the content on the page No. 9

Initial Installation QUALIFIED INSTALLERS ONLY ELECTRICAL REQUIREMENTS: The ENVIRO EG40 will operate without electrical power. This model has a millivolt gas control, which uses the pilot flame to generate enough electricity to operate the main burners. The appliance is equipped with a blower and must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICA

Summary of the content on the page No. 10

Initial Installation REPLACING THE BLOWER: 1. Turn the unit off and remove the log set. 2. Remove the brick liner. 3. Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift the tray out. 5 4. Remove the four (4) /16” bolts that hold the blower mounting plate to the back firewall. Use a light lubricating oil on screws before removal. 5. Carefully pull the blower assembly into the firebox (see Figure 8) disconnect the blowe

Summary of the content on the page No. 11

Initial Installation FUEL CONVERSION: WARNING: This conversion kit shall be installed by a qualified service technician in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or CO poisoning may result. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete u

Summary of the content on the page No. 12

L O I P T O L T P T H T P T H I P F F Initial Installation GAS LINE CONNECTION AND TESTING: WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in a 3⁄8” male NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow e

Summary of the content on the page No. 13

Secondary Installation INSTALLATION OF LOG SET AND EMBERS: The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner come with five (5) locator pins, and the rear log has one (1) ledge, which make alignment easier. Using the pictures provided, carefully set the logs in place. NOTE: The logs are fragile and should be handled gently. CAUTION: Use only the type of ember material supplied with this applianc

Summary of the content on the page No. 14

Secondary Installation L e d g e f o r R i g h t L o g 4. Upon the first light up, watch for ignition to ALL burner ports. If a long delay is noted: First, wait for the appliance to cool down. • Open the front door of the appliance. • Check to carefully reposition the embers making sure that burner ports are not P i n f o r R i g h t L o g plugged solid or blocked. Important note: When the unit is turned on for the first time, It should be turned Figure 14: Step 4 of Log Placement. onto

Summary of the content on the page No. 15

Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OR LIFE. A) This appliance is equipped with a pilot that must be lit by hand by following these instructions exactly. B) BEFORE LIGHTING smell all around the appliance area for gas, and next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YO

Summary of the content on the page No. 16

Routine Maintenance and Service Annually check to ensure that your Venting system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no or very small yellow tips. OPENING THE DOOR Turn unit off and wait until the appliance has cooled down. 1. Open the right hand hinged side flap, which will expose a door � � � � � � � � � � � � � � � � � � � � fastener.

Summary of the content on the page No. 17

Trouble Shooting Problem Possible Cause Solution Spark will not light the Defective piezo ignitor. • Check connections to ignitor. pilot after repeatedly • If ignitor connections are good but there is no spark; pressing the spark ignitor replace ignitor. Broken spark electrode. • Check for broken ceramic insulation. • Replace electrode if broken. Misaligned spark electrode. • If spark is not arcing from electrode to pilot - adjust by loosening the screws on the pilot base. Adjust away from bu

Summary of the content on the page No. 18

Parts List Reference Part Description Part Number Number 1 120 °F (49 °C) Ceramic Temperature Sensor EC-001 2 220 °F (104 °C) Ceramic Spill Switch EC-002 3 S.I.T. NOVA Valve NG (50% turn down) EC-006 3 S.I.T. NOVA Valve LP (50% turn down) EC-007 4 Thermocouple EC-009 4 Spark Electrode with Ignitor Cable EC-011 4 Thermopile EC-012 4 Fully Assembled Pilot NG EC-015 4 Fully Assembled Pilot LP EC-016 4 Pilot Orifice NG Threaded EC-019 4 Pilot Orifice LP Threaded EC-020 Pilot Gasket EC-021 5 S.I.T

Summary of the content on the page No. 19

Parts List Reference Part Description Part Number Number BV Owner’s Manual EG40-071 14 Pedestal EG40-080 15 Side Panel EG40-086 16 BV Stove Top EG40-087 Firebox Baffle EG40-088 Stove Top Baffle BV EG40-091 Venturi Cover Plate EG40-097 17 Front Venturi EG40-098 18 Bar Set - Painted (3 pieces) EG40-114 18 Bar Set - Gold (3 pieces) EG40-115 18 Bar Set - Nickel (3 pieces) 50-478 Burner Gasket EG40-120 Steel Brick Liner EG40-129 Brick Liner Backing EG40-130 19 Pedestal Door EG40-135 LP to NG Convers

Summary of the content on the page No. 20

Parts Diagram - Chassis � � � � � � � � � � � � � � � � � � � � � � � E G 4 0 B o d y ( C h a s s is ) Ju l y 2 004 20


Alternative user manuals
# User manual Category Download
1 Enviro Ascot 50-029 User manual Indoor Fireplace 0
2 Enviro Ascot User manual Indoor Fireplace 0
3 Enviro ASCOT VENTED GAS FIREPLACE HEATER User manual Indoor Fireplace 2
4 Enviro DV50DX User manual Indoor Fireplace 0
5 Enviro C-10791 User manual Indoor Fireplace 0
6 Enviro C-11275 User manual Indoor Fireplace 0
7 Enviro DV42DX User manual Indoor Fireplace 1
8 Enviro EG.95.FPI.BV.LPG User manual Indoor Fireplace 0
9 Enviro DV36 User manual Indoor Fireplace 0
10 Enviro EG 28 User manual Indoor Fireplace 0
11 Enviro C-11288 User manual Indoor Fireplace 1
12 Enviro EG 95as User manual Indoor Fireplace 0
13 Enviro EF3 User manual Indoor Fireplace 81
14 Enviro EG-40 User manual Indoor Fireplace 1
15 Enviro User manual Indoor Fireplace 13
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1