Enviro user manual

User manual for the device Enviro

Device: Enviro
Category: Indoor Fireplace
Manufacturer: Enviro
Size: 2.68 MB
Added : 5/9/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Enviro . Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Enviro .

For your convenience

If looking through the Enviro user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Enviro on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Enviro to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Enviro User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Enviro but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Enviro . If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Retreat
D I R E C T V E N T F I R E P L A C E
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S
MANUAL
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use any phone
in your building.
• Immediately call your gas supplier from a

Summary of the content on the page No. 2

Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn

Summary of the content on the page No. 3

Table of Contents Safety Precautions...............................................................................................................2 Table of Contents................................................................................................................3 Codes And Approvals...........................................................................................................4 Specifications..............................................................................

Summary of the content on the page No. 4

Codes And Approvals DIRECT VENT ONLY: This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 200

Summary of the content on the page No. 5

Specifications INSTALLATION OPTIONS: • Parallel to a wall or placed in a corner • With a floor hearth or raised up the wall • Vertical or horizontal venting WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. DIMENSIONS: 5 12 / 1 6 " (3 12mm ) 5 6 / 8 " ( 1 6 8 m m ) o 45 4" ( 102m m ) 7 13 / 1 6 " ( 342m m ) 3 8" 7 / 16 " ( 203m m ) (183 m m ) 1 1 1 / 2 " ( 292m m ) 1 8 / 8

Summary of the content on the page No. 6

Summary of the content on the page No. 7

Summary of the content on the page No. 8

Summary of the content on the page No. 9

Maintenance And Service ROUTINE MAINTENANCE: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua

Summary of the content on the page No. 10

Summary of the content on the page No. 11

Maintenance And Service FUEL CONVERSION: TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result c

Summary of the content on the page No. 12

Maintenance And Service 7. Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 9. 5 b) Insert a /32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 10), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. L o o s e n T i g h t e n d) Flip the screw (refer to Figure 11). e) Using the Allen wrench as shown in Figure 10, rotate the screw clockw

Summary of the content on the page No. 13

Initial Installation QUALIFIED INSTALLERS ONLY INTRODUCTION: This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantles, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual. Warning: Clearances must be sufficient to allow access for maintenance and

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Initial Installation QUALIFIED INSTALLERS ONLY The gas line, 3⁄8 inch NPT, can be brought to either the right side, the left side, or the bottom of the fireplace. If this set up is inconvenient, the electrical wire and the gas line configuration can be reversed. The location should be chosen so the fireplace must be at least 36 inches (91.4 cm) from drapes, doors and other combustibles. The framed opening should also be a minimum of 6.5 inches (16.5 cm) from the nearest perpendicular wall (

Summary of the content on the page No. 16

Summary of the content on the page No. 17

Summary of the content on the page No. 18

Initial Installation QUALIFIED INSTALLERS ONLY MANTEL CLEARANCES: It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines. Top of unit to 2x4 header framing: 0” (0 cm) Top of unit to bottom of 3⁄4” (1.9 cm)-1” (2.5 cm) facing: 21⁄2” (6.4 cm) Top of unit to bottom of 31⁄2” (8.9 cm) mantel: 13” (33.0 cm) Top of unit to bottom of 12” (30.5 cm) mantel or ceiling: 133⁄4” (34.9 cm) C o m bu s t i b l e boa r d 1 2" ( 3 0 5 m m ) 1 3 / 2 " ( 89m m ) C o

Summary of the content on the page No. 19

Initial Installation QUALIFIED INSTALLERS ONLY VENT TERMINATION RESTRICTIONS: N O H D E B C B F i x e d B G C l os e d L F i x e d O pe n a b l e F Cl ose d G O p e na b l e M J K B A I A Te r m i na t i o n C a p A i r S u p p l y I nl e t R e s tr i cti o n Z o n e G G a s M e te r ( T e r m i na t i o n n o t a l l o w e d ) Figure 30. Vent Termination Restrictions, refer to Table 4. Table 4: Vent termination clearances, refer to Figure 30. 1 2 Letter Canadian Installation US Installation De

Summary of the content on the page No. 20

Initial Installation QUALIFIED INSTALLERS ONLY FIREPLACE HORIZONTAL VENT KIT 50-1235: Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury. KIT COMPONENTS: Qnty Description Qnty Description 1 Horizontal direct vent termination cap 4 Wire spacers 1 Flue collar adapter 1 4 oz tube Mill-Pac Sealant 1 Wall thimble 1 4 oz tube RTV silicone 9 1 5’ (190 cm) length of Ø4” (10 cm) double walled fle


Alternative user manuals
# User manual Category Download
1 Enviro Ascot 50-029 User manual Indoor Fireplace 0
2 Enviro Ascot User manual Indoor Fireplace 0
3 Enviro ASCOT VENTED GAS FIREPLACE HEATER User manual Indoor Fireplace 2
4 Enviro DV50DX User manual Indoor Fireplace 0
5 Enviro C-10791 User manual Indoor Fireplace 0
6 Enviro C-11275 User manual Indoor Fireplace 0
7 Enviro DV42DX User manual Indoor Fireplace 1
8 Enviro EG.95.FPI.BV.LPG User manual Indoor Fireplace 0
9 Enviro DV36 User manual Indoor Fireplace 0
10 Enviro EG 28 User manual Indoor Fireplace 0
11 Enviro C-11288 User manual Indoor Fireplace 1
12 Enviro EG 95as User manual Indoor Fireplace 0
13 Enviro EF3 User manual Indoor Fireplace 81
14 Enviro EG-40 User manual Indoor Fireplace 1
15 Enviro EG40 BV User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1