Summary of the content on the page No. 1
N
O
L
I
I
T
S
A
INSTALLATION AND
OPERATION MANUAL
GARLAND RTCS TECHNOLOGY BUILT IN
INDUCTION COOKERS,
MODELS: BH/IN 2500, SH/IN 3500,SH/IN 5000,
SH/WO/IN 3500,SH/WO/IN 5000 & SH/WO/IN 8000
C CM
86037
PLEASE READ ALL SECTIONS OF THIS MANUAL
FOR YOUR SAFETY: AND RETAIN FOR FUTURE REFERENCE.
DO NOT STORE OR USE GASOLINE
THIS PRODUCT HAS BEEN CERTIFIED AS
OR OTHER FLAMMABLE VAPORS OR
COMMERCIAL COOKING EQUIPMENT AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
MUST BE INSTALLED BY
Summary of the content on the page No. 2
Page 2 Part # 4520898 (03/31/11)
Summary of the content on the page No. 3
IMPORTANT INFORMATION The instructions in this manual are fundamentally important and must be taken into account during assembly, operation Warning and maintenance. They must therefore be read very carefully Risk of fire or electric before installation and operation by the responsible shock specialist staff and the operator(s). After installation keep in a promenade position for consultation and reference. Do not open To reduce the risk of fire or electric Description Of Warning Signs s
Summary of the content on the page No. 4
Page 4 Part # 4520898 (03/31/11)
Summary of the content on the page No. 5
TABLE OF CONTENTS Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . 19 IMPORTANT INFORMATION . . . . . . . . . .3 . . . Operating Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Description Of Warning Signs. . . . . . . . . . . . . . . . . 3 Health Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 OPERATION . . . . . . . . . . . . . . . . . . . . 20 . . . . . . . Cooking Process . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Summary of the content on the page No. 6
DIMENSIONS AND SPECIFICATIONS OPERATING CONDITIONS Maximum Tolerance of +6/-10% Supply Voltage Supply Frequency 50/60 Hz Protection Class IP XO Minimal Diameter Of The Pan 4 3/4” (120mm) (BH/IN and SH/IN) Storage -4º to 158 ºF (-20 º to 70ºC) Maximum Ambient Temperature Function 41 º to 104 ºF (5º to 40ºC) Storage 10%-90% Maximum Relative Humidity Of Air Function 30%-90% ELECTRICAL SPECIFICATIONS MODEL VOLTAGE Total KW BH/IN2500 208/230/240 2.5 SH/IN 3500 208/230/240 3.5 SH/IN 5000 208/230/
Summary of the content on the page No. 7
GENERAL INFORMATION Purpose Of Induction Cookers Control knob The induction cookers are especially suitable as built-in The number that points to the operation indicator marks the cookers in closed counters for the preparation of meals. The actual position of the control knob. cookers can be used for cooking, keeping warm, flambéing, roasting, etc. of food. Only recommended types and sizes of OFF-POSITION pans should be used. Do not use NO NAME pan material but 0 Points to the operation indi
Summary of the content on the page No. 8
INSTALLATION The generator is delivered with firmly fixed built-in frame Electrical Supply including glass top and separate operating unit. Please observe the following rules: Please note that the unit is 1. Check and ensure that the supply voltage and the line not completely assembled. current matches the specifications given on the rating plate. CAUTION Pay close attention to the requirements for 2 This induction appliance is equipped with mains cable installation section. and plug wh
Summary of the content on the page No. 9
INSTALLATION continued Cut Out For Model BH/IN 2500 The size of the cut out in the built-in area must be, 11.41” x 11.41” (290 x 290mm), the depth 7.87” (200mm) and the base at least 13.39” x 11.75” (340 x 273mm). 0.06" [1.5mm] Side View of the right Front view 4.06" 5.04" [103mm] [128mm] 7.32" air exit air exit [186mm] Ventilator Connection clutch for Mains operation device Cable 3.07" air supply Plug-in clutch for [84mm] 6.73" operation device [171mm] 11.02" 11.02" [280mm] [280mm] 10.23"
Summary of the content on the page No. 10
INSTALLATION continued Cut Out for Models SH/IN 3500 And SH/IN 5000 The size of the cut out in the built-in area must be 13.78” x 13.78” (350 x 350mm), the depth 9.45” (240mm) and the base at least 16.14” x 13.90” ( 410 x 353mm). 0.06" [1.5mm] Side view of the right Front view 5.63" [143mm] 7.13" [181mm] 8.90" Plug-in for [226mm] Air exit Air exit operating device Ventilator Net cable 7.20" Plug type connection Air Supply 3.86" [183mm] for operating device [98mm] 12.99" 13.03" [330mm] [331m
Summary of the content on the page No. 11
INSTALLATION continued Cut Out For Models SH/WO/IN 3500, SH/WO/IN 5000 And SH/WO/IN 8000 The size of the cut out for the built in area must be 14.37” x 14.37” (365 x 365mm), the depth 11.81” (300mm) and the base at least 16.14” x 13.90” (410 x 353mm). 0.06” Side view of the right Front view (1.5mm) Air exit Air exit 14.31” (363.5mm) 8.46” (5mm) 9.92” (252mm) 16.69” (297mm) Net cable Ventilator Connection clutch for operation device 3.86” 7.20” Plug-in clutch Air supply 13.03” for operatio
Summary of the content on the page No. 12
INSTALLATION continued Unit Placement Installation of Operating Unit After the cut out has been made according to the previous Each unit is supplied with a complete operating unit. In order sections, apply silicone to the top of the counter and press to fix this unit on the surface of the enclosure, a cut out for the induction unit into the silicone, allowing for a complete the power switch and the LED must considered. The operator water tight seal between the unit and the counter. Make sure
Summary of the content on the page No. 13
INSTALLATION continued Figure # 1 Cut Out Opening Silicone Louvered Air Exhaust Opening (By Installer) Sleeve with hose clip: mounted on bottom of unit Aluminum air duct (Max 96" (8')) Sleeve with hose clip: mounted on collars mounted to cabinet with hose clamps Removable grease lter and air intake housing mounted on cabinet Air Intake Housing See Fig. # 2 Fresh Air Supply Fresh Air Intake Installation Figure # 2 - Air Intake Housing The built-in induction units require a cooling air intake to
Summary of the content on the page No. 14
INSTALLATION continued Figure 2 Continued - Cut Out Guidelines For Assembly The underside and sides of the induction unit must be 4 HOLES absolutely clear of obstructions to provide for adequate cooling air to enter and exhaust. Install a flexible air duct including shackle provided with your built-in induction cooker. Clearances between openings for air supply and air exhaust to obstacles (walls or floors), must be maintained to provide clearances of at least 4” (102mm). The outgoing air
Summary of the content on the page No. 15
Part # 4520898 (03/31/11) Page 15 3
Summary of the content on the page No. 16
Page 16 Part # 4520898 (03/31/11) Figure # 4
Summary of the content on the page No. 17
Part # 4520898 (03/31/11) Page 17 Figure # 5
Summary of the content on the page No. 18
Page 18 Part # 4520898 (03/31/11) Figure # 6
Summary of the content on the page No. 19
INSTALLATION continued 1 Put some water in the pan and place it in the center of the Electrical installation heating area. If the voltage is wrong, the 2. Turn the control knob to an ON position. The indicator CAUTION cooker can be damaged. will light up (green) and the water will be heated. 3. Take the pan away from the heating area, the indicator The electrical installation must be done by approved light will flash. installation contractors in accordance with specific national and local
Summary of the content on the page No. 20
OPERATION Cooking Process Safety Concerns Risk Involved By Disregarding Safety Information The induction cooker is switched on by turning the control knob (OFF ➯ ON) and it is immediately ready for operation. Danger for persons, the environment and the cooker as The luminous operation indicator light means that energy well as claims for damages of any kind can result from is being transferred to the pan. The power rating is set by disregarding safety information. Certain risks may be turn