ملخص المحتوى في الصفحة رقم 1
SELECTRONIC™
PROXIMITY URINAL FLUSH VALVE
0.5 & 1.0 GPF
MODEL NUMBERS
6063.510 6063.051
6063.505 6063.101
Exposed Flushometer
for 3/4" Top Spud Urinals
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
Certified to comply with ASME A112.19.2M
© 2008 AS
ملخص المحتوى في الصفحة رقم 2
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. All American Standard Products Are Water Tested At Our Factory. UNPACKING Some Residual Water May Remain In The Valve During Shipping. 1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be pack
ملخص المحتوى في الصفحة رقم 3
Fig. 1 GENERAL DESCRIPTION: Roughing-in Dimensions SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE DETECTION ZONE 400mm-800mm Exposed Flushometer (15-3/4 TO 31-1/2) for 3/4" Top Spud Fixtures 72mm FINISHED WALL (2-7/8) Exclusive, self cleaning piston-type flush 57mm (2-1/4 MIN.) valve with proximity operation and manual override. Operates on DC 15˚ (battery) power. Recommended 116mm operating pressure 35 to 80 psi. Can (4-5/8) install left or right-handed. Detection Zone can also be adjusted m
ملخص المحتوى في الصفحة رقم 4
INSTALL SWEAT SOLDER 1 Fig.3 Fig.3a ADAPTER; Fig. 3 FINISHED WALL CENTER LINE OF Turn water supplies off CAUTION FIXTURE SPUD before beginning A Note: Install Optional Sweat Solder Adapter (Supplied) for copper pipe supply line. Fig. 3. (A-B)= 1. Measure the distance (A) from the finished wall to the B 32mm C center of the inlet spud on the fixture. (1-1/4) FILE EDGES 2. Cut the supply pipe 1-1/4" (A-B=C) shorter then the measurement taken in Step 1. File any rough edges off the end
ملخص المحتوى في الصفحة رقم 5
FLUSH OUT SUPPLY LINES; Fig. 6 4 Fig. 6 2 1. Remove COVER (1) from SUPPLY STOP (2). REMOVE COVER 2. With a flat blade screwdriver open SUPPLY STOP (2). 1 3. Turn on water supply to flush line of any debris or sediment. 2 COUNTER-CLOCKWISE 4. Close SUPPLY STOP (2) and replace COVER (1). OPENS CONTROL STOP CLOCKWISE CLOSES CONTROL STOP Fig. 7 4 LEFT OR RIGHT HAND 5 3 INSTALLATION; Fig. 7 The UNIT is shipped with the inlet flange on the right 2 side. If needed, the orientation can be reverse
ملخص المحتوى في الصفحة رقم 6
6 INSTALL FLUSH VALVE; Fig. 8a Fig. 8a & 8b 3 1. As shown in Fig. 8a, insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. 2. Align the FLUSH VALVE (2) (Fig. 8b) directly above the DOWN TUBE (7) and VACUUM BREAKER COUPLING NUT (6). Make sure that GASKET (10) is
ملخص المحتوى في الصفحة رقم 7
HOW TO RETROFIT OUR VALVE; 8 Fig. 10 Fig. 10a Fig. 10b Fig. 10 6 CLEAN 2 CONNECTIONS (Replaces Industry Standard Manual and 1 Electronic Valves) Note: In most Retrofits the wall escutcheon, supply stop, 4 cover tube and vacuum breaker do not have to be replaced. If these items do need replacement they must be purchased 5 separately or order the complete flush valve assembly from 3 American Standard. 1. Remove COVER (1) from SUPPLY STOP (2) if installed. Fig. 10. 2. Turn water supply of
ملخص المحتوى في الصفحة رقم 8
HOW HOW TO TO SET SET DETECTION DETECTION RANGE RANGE 10 11 Fig. 13 (If Required) ; (If Required) ; Fig. 13 & 14 Fig. 13 Note: The detection distance is preset and is ideal for 6 most installations. Should an adjustment be required Fig. 13a Fig. 13b follow the steps below. 3 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of top half of FLUSH VALVE (3). Fig. 13a. 2. Rotate CAP (3) to the right and pull off. Fig. 13b. 1 VIEW “A” 3. Turn CAP (3) over and disconnect GREY SEN
ملخص المحتوى في الصفحة رقم 9
M968567 Rev.1.2 8 Installation Instructions Installation Instructions UNIT WILL ONLY FLUSH MANUALLY UNIT DOES NOT FLUSH AT ALL IS STOP VALVE OPEN? NO OPEN VALVE LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES BATTERY LOW; YES REPLACE BATTERY SEE STEP 10, page 6 NO in manual LOOK FOR REPEATED YES INSTALL NEW BATTERY DOUBLE FLASH ON SENSOR 1. COVER SENSOR FOR 10 SECONDS 2. UNCOVER SENSOR FOR 10 SECONDS. NO RETRY AUTOMATIC FLUSH. TRY MANUAL VALVE BUTTON; DOES THE UNIT FLUSH? NO REPLACE PISTON KIT WI
ملخص المحتوى في الصفحة رقم 10
SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE 0.5 & 1.0 GPF M962665-0020500A MODEL NUMBERS COVER ASSEMBLY FOR FLUSH VALVE WITH 0.5 gpf (BATTERY INCLUDED) 6063.510 6063.051 M962665-0021000A 6063.505 6063.101 COVER ASSEMBLY FOR FLUSH VALVE WITH 1.0 gpf (BATTERY INCLUDED) A923654-0070A BATTERY 6VCR-P2 A950223-0070500A SENSOR ASSEMBLY W/MTG. KIT. A906680-0070A FOR FLUSH VALVE BONNET NUT WITH 0.5 gpf A950223-0071000A SENSOR ASSEMBLY W/MTG. KIT. FOR FLUSH VALVE M962664-0070A WITH1.0 gpf SOLENOID ASSEMBLY