ملخص المحتوى في الصفحة رقم 1 
                    
                        Room Air Conditioner
Aire Acondicionado para Habitaciones 
        Use and Care Manual
    Manual de Uso y Mantenimiento
Remote control
Airconditioner
Timer
AAW-10CR1FHU
  Fan
Mode
Speed
AAW-10DR3FHU
AAW-12CR1FHU
AAW-12DR3FHU
AAW-18CR3FHU
AAW-18DR3FHU
AAW-24CR3FHU
AAW-24DR3FHU
O F F
5 H IG H H IG H
7 F A N COOL
3 9 MED MED
FA N COOL
1 1
F LO AN W LO CO W OL
Mechanical control
AAW-10CM1FHU
AAW-12CM1FHU
AAW-18CM3FHU
AAW-24CM3FHU
Thank you very much for purchasing an   A    d  m  ir  al    Air Cond
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Table of Contents Page Introduction 2 2 Parts Identification 4 Electrical Specifications 5 Tips  Before Installation Installation Instructions 6 11 Operating Instructions Care and Maintenance 15 Trouble Shooting Guide 16 Warranty 17 17 ndice P gina Introducci n 18  18 Identificaci n de las Piezas  20 Especificaciones El ctricas Consejos Antes de la Instalaci n 21 Instrucciones de Instalaci n 22 Instrucciones de Operaci n  27 Cuidado y Mantenimiento 31 Gu a para la Soluci n de Problemas 32 Garant
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        3 1 OFF HIG H HIG H FA N C O O L MED M E D FAN CO O L L FO AN W L C O O W OL 5 7 3 9 1 Introduction Thank you for choosing this room air conditioner to cool your home. This USE AND CARE MANUAL provides  information necessary for the proper care and maintenance of your new room air conditioner.  If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid  installation difficulties, read instructions completely before starting. This manual contains inf
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Introduction Part Identification  Remote control model Front Panel Cabinet Control Panel  Air Outlet Air Filter Interior Air Inlet Grille Fresh Air  Vent Lever Exterior Air Inlet Power Cord Remote Control Remote Control Control Panel Power T i m e r Airconditioner Mode Power Saver A u t o Mid Fan Speed High Low _ + Te m p / T i m e Timer   Fan Mode Speed Note: The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air co
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Electrical specifications 1. All wiring must comply with local and national ! Electric Shock Hazard electrical codes and must be installed by a  licenced electrician.  If you have any questions If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps, regarding the following instructions, contact a  the unit maybe on a fuse or circuit breaker licenced electrician. with other devices.  However, the maximum  amps on all devices for  that fuse or circuit  2. Ch
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                         Tips before installation Your Room Air Conditioner unit is designed to  ! CAUTION ! be highly  efficient and save energy. Follow these To avoid installation/operating difficulties, recommendations for greater efficiency. read the instructions thoroughly. 1. Select thermostat setting that suits your  comfort needs and leave the thermostat at  that chosen setting. NOTE:      Save the shipping carton and packing  materials for future storage or transport of the unit.  2. The air  filter is very ef
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Installation instructions E. Be certain the proper electrical outlet is within reach ! CAUTION ! of the installation.  Use only a single outlet circuit rated at  proper current (see table 1 on page 4).  All wiring  Because the compressor is located on the  should be in accordance with local and national  controls side of the unit (right side), this side will be heavier and more awkward to manipulate. electrical codes. Inadequate support on control side of the unit can result in personal injury a
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        B WE A FO T R H ER R EE ES M TAR UTE NS G  Airconditioner F R ON/OFF H IT IN TI T I M E R   FAN SP EED MODE Installation instructions 2. Preparation to Remove the  Air Conditioner Slide-Out Chassis A. Remove total of  (4) Philips screws securing the chassis to the cabinet. There are (2) screws  on each side. The set of screws closest to the  front of the unit secure the front panel to the  cabinet. The set of screw closest to the rear of  Right side Philips screws the unit secure the cabinet to 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Installation instructions 5. Installation of Mounting Brackets and (TOP VIEW) First Sealing Strip V-slot          NOTE: Windows come in a variety of different  styles. Therefore, it may be necessary to modify Bracket Assembly or improve  your particular installation. 90  Angle Support Brackets Bracket Bolts Leveling Screw A. Attach the bracket assembly to 90 angle support  brackets (Fig. 5) using (2) 1 1/2"  bolts  Fig. 5 Two bolts per bracket. Secure with the (2)  1/4" lock washers and (2) 1/4"
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        R O T IM E M DE S  P FA EE ND Airconditioner HF R ON/OFF B WE AF IT O T RH ER R E E E S M TA IN RU TT IN EG S  Installation instructions 6. Installation of the cabinet   A. Align one hole in the bottom of the cabinet with one  hole in the bracket assembly. Secure the cabinet to the 1/4" Screws bracket using (3) 1/4" screws provided. Repeat the  same procedure on the opposite side of the cabinet.  See (Fig. 10). B. Ensure the "L" shaped mounting channel is  positioned in front of the sash. The  b
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Installation instructions 9. Complete the installation A. Cut the foam to fit the opening between the top of   Foam the inside and outside window. See (Fig. 13). B. Some installations may require additional sealing  around the window and air conditioner. Check for any  air leaks and seal where necessary. Fig. 13 C. In very humid areas, the water removal may be  excessive enough to overflow the unit or increase the  noise of the air conditioner. If this occurs, you may wish to attach a drain hose
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        W IT R HR MIN R U TIN Airconditioner F HR ON/OFF BE AFO T E R EE ESTA TES G  TI ME R   FAN SPEED MODE Operating Instructions  Mechanical control model MODE The mode knob controls fan speeds and cooling speeds. To set desired cooling temperature, simply rotate the mode knob dial to the appropriate OFF setting. HIGH HIGH 5 7 FAN COOL THERMOSTAT 3 3 9 MED MED The thermostat automatically controls the cooling  FAN COOL cycle (compressor) of the air conditioner to maintain 1 1 LOW LOW FAN COOL room t
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Operating Instructions Control Panel Electronic  control panel model You can easily operate this air conditioner by pressing  relevant button  on the control panel as well as the  remote control. Airconditioner           Button The air conditioner will be started when it is energized or will be stopped when it is in operation, if you press this button. Timer When the air conditioner is heating, allow  3 minutes after you  press this button.   Fan Mode Speed Mode button Each time  MODE button is 
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Operating Instructions  Remote control           Power BUTTON 1 The appliance will be started when it is energized or will be stopped when it is   in operation, if you press this button. 1 8 Power Timer 2 Mode BUTTON 2 9 Mode Power Saver Used to select the operation mode. 7 5              BUTTONS 3 Auto Mid Fan Speed Used  to  set room  temperature  in Cooling 6 4 mode  or used to set   time  in Timer  mode. High Low _ + 3 4 High BUTTON    Temp/Tim e Used to select the high fan speed  mode. Mid 
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        W IT HR MINU R RTIN Airconditioner F HR ON/OFF A T EE TES  BEFO E RESTA G TI ME R   FAN SPEED MODE Operating Instructions  Remote control How to Insert the Batteries Remove the battery cover according to the arrow direction.  Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR06 AA(1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the 
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Care and Maintenance When servicing the air conditioner, be sure to ! ! CAUTION turn the mode switch to the "OFF" position and disconnect the power cord from the electrical outlet. DO NOT forget to install the air filter. If the air conditioner is left to operate without the air filter, dust is not removed from the room and may 1. DO NOT use  gasoline, benzine, thinner or  cause your air conditioner to fail. other chemicals on the air conditioner as these When the air filter inlet grill and cabi
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Troubleshooting Guide Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a  possible solution.  PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Air conditioner will No power to the unit. Check connection of power cord to not operate power source. Check fuse or circuit breaker. Set FAN CONTROL to position other than "OFF". Inefficient or no cooling Dirty air filter. Clean or replace  air filter. Inappropriate capacity Check with dealer to determin
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Warranty 5 YEAR FULL WARRANTY This product is warranted for 5 years from the date of original purchase.  Any part which fails in materials or workmanship will be replaced within the warranty period. This warranty covers in home service.  A copy of your proof of purchase, with date of purchase and product name included, is required to arrange this service repair. For the name and location of an authorized service provider nearest you, please CALL 1-877-465-3566. Please reference product name, bra
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        3 1 OFF FHAIGNH HCIGOOHL MED MED FAN COOL LFOANW LCOOWOL 5 7 3 9 1 Introducci n Gracias por elegir este aire acondicionado para enfriar su hogar. Este MANUAL DE USO Y MANTENIMIENTO  proporciona la informaci n necesaria para cuidar y mantener en forma adecuada su nuevo aire acondicionado.  Funcionar sin problemas durante muchos anos si le brinda el mantenimiento apropiado. Para evitar  problemas al instalarlo, lea completamente las instrucciones antes de comenzar. Este manual contiene  informaci 
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Speed Introducci n Identificaci n de las Piezas  Modelo de Remoto controlador Entrada de Panel de Control Panel Frontal Gabinete  Aire Interior Filtro de Aire   Rejilla de  Entrada de  Aire Interior  Entrada de  Aire Exterior  Palanca  de Aire Fresco  Cable de Alimentaci n  Panel de Control  Control Remoto  Power T i m e r Airconditioner Mode Power Saver Mid Auto Fan Speed High Low Timer _ + Temp/Time   Fan Mode Speed Nota:  Las im genes de este manual est n basadas en la vista externa de un mod