                        DO NOT
DISCARD
Owner’s Manual
Installation and Operation
TIARA I-B
TIARA II-B
Portland
Tested and 
O O-T -T L
Listed by Oregon USA
DIRECT VENT ROOM HEATER 
US
C
OMNI-Test Laboratories, Inc.
Models: 
TIARAI-BK-B TIARAII-BK-B
TIARAI-BR-B TIARAII-BR-B
TIARAI-CTO TIARAII-CTO
TIARAI-CES TIARAII-CES
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating and • Read, understand and 
• Leave this manual with 
maintenance instructions follow these instructions party responsible for use 
for safe install
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Read this manual before installing or operating this appliance. Please retain this owner's manual for future reference. Congratulations This Owner's Manual should be retained for future reference.  Congratulations on selecting a Heat & Glo gas appliance -  We suggest that you keep it with your other important  an elegant and clean alternative to wood burning appliances.   documents and product manuals. The Heat & Glo gas appliance you have selected is designed  to provide the utmost in safety, r
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        - TABLE OF CONTENTS - Section 8: Appliance Setup Section 1: Listing and Code Approvals  A. Remove Shipping Materials ................30  A. Appliance Certifi cations ......................4  B. Top to Rear Conversion ......................30  B. Glass Specifi cations ............................4  C. Damper Adjustment ............................31  C. Specifi cations ......................................4  D. Shutter Adjustment .............................32  D. High Altitude Installations .....
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Listing and Code Approvals 1 C.  Specifi cations A.  Appliance Certifi cation Maximum Minimum Orifi ce *Steady  **P.4 Model Input Input Size State  % (US or Canada) BTU BTU Effi ciency  MODEL Tiara I B % LABORATORY OMNI-Test Laboratories, Inc. Tiara I B 31,000 22,000 .106 81.43 57.33 061-S-43b-5 (NG) TYPE Vented Gas Fireplace Heater Tiara I B 30,000 23,000 .063 82.75 56.39 (LP) STANDARD ANSI Z21.88-2002 ּ CSA 2.33-2002  Maximum Minimum Orifi ce *Steady  **P.4 UL307b ּ CAN/CBA 2.17-M91 Model Input Inp
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Inspection NOTE: The following requirements reference various  The state or local gas inspector of the side wall horizontally  Massachusetts and national codes not contained in this  vented gas fueled equipment shall not approve the installa- document. tion unless, upon inspection, the inspector observes carbon  monoxide detectors and signage installed in accordance with  G.  Requirements for the Commonwealth of      the provisions of 248 CMR 5.08(2)(a) 1 through 4.       Massachusetts Exemption
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Getting Started 2 C. Inspect Appliance & Components A.  Design & Installation Considerations Heat & Glo direct vent gas appliances are designed to oper- ate with all combustion air drawn from outside of the building  WARNING and all exhaust gases expelled to the outside. No additional  air source is required. Inspect appliance and components for  damage. Damaged parts may impair safe  operation. CAUTION • Do NOT install damaged components. • Do NOT install incomplete components. Check building c
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Appliance Location and Clearances 3 NOTE:  WARNING ·  Illustrations refl ect typical installations and are FOR  Fire Risk  DESIGN PURPOSES ONLY. Provide adequate clearance: ·    Illustrations/diagrams are not drawn to scale. • Around air openings ·   Actual installation may vary due to individual design   • To combustibles • For service access  preference. Locate appliance away from traffi c areas. A. Selecting Appliance Location When selecting a location for your appliance it is important to  WAR
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        C. Clearances to Combustibles - Tiara II-B F  C  B  C  E  A A  "A" measurement is from  appliance top, not side  H  G  G   A A  D 90˚ off top up and out ceiling  H Top of Side of Inside  Model A B C D E F G pipe pipe Outside  corner  wall vent Inches Tiara II B 5-1/4 1/4 3/8 54 36 40 31-3/4 1-1/2 1 9 Millimeters 133 6 9.5 1372 914 1016 806 38 25 229 Figure 3.1    For both the Tiara I-B and Tiara II-B, it is permissible to place  the appliance on carpet. WARNING Fire Risk.  CAUTION Odor Risk. Tip
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Termination Locations 4 A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG WARNING 2 FT. 20 INCHES MIN. VERTICAL MIN. Fire Risk. WALL LOWEST  Explosion Risk. DISCHARGE  OPENING Maintain vent clearance to combustibles  GAS DIRECT VENT  as specifi ed. TERMINATION CAP • Do not pack air space with insulation or  X other materials. 12 Failure to keep insulation or other materials  away from vent pipe may cause fi re. ROOF PITCH IS  X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE O
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        M  N  P  G R  v  A  H  D Q  (See Note 2)  E  v  V  B  L  U.S.  B T  v  (3 FT)  v  B B  v  S S  Electrical  V  V  Service  F  v v M  I  D*  v X  A J or K V  = VENT TERMINAL X  = AIR SUPP L Y INLET = ARE A WHERE TERMINA L IS NOT PERMITTED  V  K = 3 ft. (U.S.A. )  A = 12 inche s ............. clearances above grade , veran-  6 f t. (Canada ) ......... clearance to a mechanical   (S ee Not  e 1 )  da, porch, deck or balcon y  (powered) a i r s uppl y inle t  B = 12 inche s ............ clearances to
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Vent Information 5 A. Venting Components B. Use of Elbows In order to comply with applicable codes and product  warranties, use only  following venting components: CAUTION •  Hearth & Home Technologies (HHT)  ALL vent confi guration specifi cations MUST be followed. •  Simpson Dura-Vent • This product is tested and listed to these  specifi cations. •  Selkirk Direct-Temp  • Appliance performance will suffer if specifi cations are  •  Amerivent Direct not  followed. •  Security Secure Vent  Diagonal 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        D. How to Use the Vent Graph E. Venting Guidelines NOTE:  IF YOUR INSTALLATION FALLS WITHIN A SHADED AREA ON  • The maximum horizontal vent run is 20 ft. (6m) when the  THE GRAPH, THE DAMPER MUST BE USED.* SEE INFORMATION ON  vertical vent rise is 10 ft. (3m). DAMPER ADJUSTMENT ON PAGE 31. *In the Commonwealth of Massachusetts, the word damper shall be replaced  • The minimum horizontal vent run is 6 in. (152mm). with the words flue restrictor. • Horizontal sections require a 1/4 in. (6mm) rise 
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        F.  Horizontal Termination WARNING Fire Hazard. Exhaust Fume Risk. Type A - Up & Out Installation Impaired Performance of Appliance. 90° ELBOW  • Ensure vent components are locked together correctly. CENTER LINE  • Pipe may separate if not properly joined.  TERMINATION CAP PIPE LENGTH  WALL THIMBLE/     HEAT SHIELD    Step 2.   WALL THIMBLE COVER  PIPE LENGTH Direct vent pipe is designed with a locking connection. To      connect the venting system to the appliance flue outlet, a  twist-lock ada
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Step 3.  For installations using a round support box/wall thimble  (check pipe manufacturer's instructions), mark the wall for a  WOOD SCREW 10 in. x 10 in.  (254mm x 254mm) square hole.  The center  of the square hole should line up with the center line of the  horizontal pipe, as shown in Figure 5.5.  Cut and frame the  hole in the exterior wall where the vent will be terminated.  If  the wall being penetrated is constructed of noncombustible  material, i.e. masonry block or concrete, a 7 in. 
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        VINYL SIDING WARNING Apply sealant to all four sides Fire Hazard. Exhaust Fume Risk. SCREWS Impaired Performance of Appliance. • Ensure vent components are locked together correctly. Bolt horizontal top to vinyl  • Pipe may separate if not properly joined.  standoff SCREWS WALL THIMBLE COVER WARNING Vinyl siding standoff with siding beneath  removed WALL THIMBLE Do NOT connect a pipe section to a termination cap without  Figure 5.8 using the telescoping fl ue section found on the termination cap.
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        G.  Vertical Termination 1. Direct Vent Pipe VERTICAL TERMINATION CAP STORM  COLLAR 35 ft. (11m)  MAXIMUM FLASHING FIRESTOP SUPPORT BOX PIPE  LENGTH Figure 5.11   Step 2. Set the gas appliance in its desired location. Drop a plumb  bob down from the ceiling to the position of the appliance  flue exit, and mark the location where the vent will penetrate  the ceiling. Drill a small hole at this point. Next, drop a plumb  bob from the roof to the hole previously drilled in the ceiling,  Figure 5.10
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Step 3. To install the round support box/wall thimble cover in a flat  CAP AND STORM  ceiling, cut a 10 in. (254mm) square hole in the ceiling,  Shingles overlap on COLLAR NOT SHOWN  top edge of flashing centered on the hole drilled in Step 2.  Frame the hole as FOR CLARITY shown in Figure 5.13. Ceiling  Joists Framing Figure 5.14   Step 7.  Continue to assemble pipe sections until the height of the  vent (before adding the termination cap) meets the minimum  1 - 1/2 in. (38mm) Long Figure 5.13 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Step 9. Twist-lock the vent cap and seal. Note:  For multi-story vertical installations, a ceiling firestop  is required at the second floor, and any subsequent floors  (Figure 5.16). The opening should be framed to 10 in. x  10 in. (254mm x 254mm) inside dimensions, in the same  manner as shown in Figure 5.13, on the previous page. Nails Ceiling Firestop Minimum 1 in.  (24mm) Clearance Minimum 1 in.  (24mm) Clearance Minimum 1 in.  (24mm) Clearance Minimum 1 in.  (24mm) Clearance Figure 5.16 WA
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        2. Cathedral Ceiling Step 1. Follow installation Steps 1 and 2 under vertical installation  section, page 16. Step 2. Remove shingles or other roof covering as necessary to cut  the rectangular hole for the support box. Cut the hole 1/8 in.  (3mm) larger than the support box outline. Step 3. Lower the support box through the hole in the roof until the  bottom of the support box protrudes at least 2 in. (51mm)  below the ceiling (Figure 5.17). Align the support box both  vertically and horizontal
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Step 4. 3. Class A Metal Chimney Pass the flex pipe down through the center of the chimney  system, and center the top adapter on the top of the chimney  pipe. Drill four 1/8 in. (3mm) diameter holes through the  top adapter, and into the chimney top. Ensure that you are  TERMINATION CAP drilling into the metal on the chimney. Twist lock the high  TOP  wind termination cap  onto the top adapter (Figures 5.22  ADAPTOR  and 5.23).  FLASHING  EXISTING  METAL  CHIMNEY  SYSTEM 4 in. (102mm)  FLEX PIP