INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
INSTALLATION AND 
OPERATION INSTRUCTIONS
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
GD82NT-T
NATURAL GAS
GD82PT-T
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING: If the information in these 
instructions are not followed exactly, a fire 
or explosion may result causing property 
damage, persona
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        2 TABLE of CONTENTS TM PG  2-5  INTRODUCTION 19         NIGHT LIGHT REPLACEMENT    Warranty    Dimensions 19-23    OPERATION / MAINTENANCE    General Instructions   Time Out    General Information   Fireplace Operation    Care of Glass & Plated Parts   Hand Held Remote Operation   Dip Switch Number Chart 5-9  VENTING   Operating Instructions    Vent lengths      Venting Specifi cations    Air Terminal Locations 24         ADJUSTMENTS   Pilot Burner Adjustment 10-15  INSTALLATION/FRAMING   Venturi
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        3 NAPOLEON® products are manufactured under the strict Standard of the world recognized  ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who  take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The  complete fi replace is thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer,  receives the qual
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        4 FIGURE 1 58" 46" 3 17 /4" 5 37 /8" 4" DIA. 7" DIA. 1 22 /8" 21" 5" 7 13 /8" 2" 7 /8" 7 8 /8" 24" 14" 28" 28" Under extreme vent confi gurations, allow several minutes  GENERAL INSTRUCTIONS (5-15) for the fl ame to stabilize after ignition.  THIS GAS FIREPLACE SHOULD BE INSTALLED AND SER- Provide adequate ventilation and combustion air.  VICED BY A QUALIFIED INSTALLER  to conform with local  Provide adequate accessibility clearance for servicing and  codes. Installation practices vary from region
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        5 and fueled with natural gas. This fi replace may be installed in an aftermarket permanently  located, manufactured (mobile) home, where not prohibited  The inner stainless steel looking fi rebox back will discolour  by local codes. with heat, turning a light brown, straw like colour that is to be  This fi replace is only for use with the type of gas indicated  considered normal. on the rating plate. This fi replace is not convertible for use  with other gases, unless a certifi ed kit is used. CARE 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        6 DEFINITIONS ELBOW VENT LENGTH VALUES     feet inches for the following symbols used in the venting calculations     1° 0.03 0.5 and examples are:  15° 0.45 6.0 > - greater than  30° 0.9 11.0 > - equal to or greater than  45° 1.35 16.0 < - less than  90°*  2.7 32.0 < - equal to or less than H - total of both horizontal vent lengths (H ) and offsets    T R   (H ) in feet O *  the fi rst 90° offset has a zero value and is shown in the      H - combined horizontal vent lengths in feet R formula as 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        7 TOP EXIT / HORIZONTAL TERMINATION V = V = 6 ft    when (H ) > (V ) 1 T T T H = 3 ft   1 Simple venting confi guration (only one 90° elbow) H = 5 ft  2 H = H + H = 3 + 5 = 8 ft R 1 2  H = .03 (two 90° elbows - 90°) = .03(180° - 90°) = 2.7  FIGURE 6 O ft H = H + H = 8 + 2.7 = 10.7 ft  T R O  See graph to determine the required verti- H + V = 10.7 + 6 =16.7 T T  cal rise V for the required horizontal run  T Formula 1: H < 4.2 V  H . T T T  4.2 V = 4.2 x 6 = 25.2 ft  T  10.7 < 25.2     Formula 2: H
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        8 TOP EXIT VERTICAL TERMINATION REQUIRED VERTICAL  when (H ) < (V ) T T RISE IN FEET See graph to  V determine the  T required vertical rise   HORIZONTAL VENT RUN PLUS OFFSET IN  V for the required  T FEET  H T horizontal run H . T The shaded area within the lines represents ac- ceptable values for H and V . T T   For vent confi gurations requiring more than zero  90° elbow (top exit) or one 90° elbow (rear exit), the  following formulas apply: Formula 1:  H < V T T Formula 2: H + V < 40 feet T T
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        9 FIGURE 12 W415-0583 / B / 05.23.07                                                                                                                                                                                                                                                                                                                                                                                                                                                                                
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        10 INSTALLATION WALL AND CEILING PROTECTION For optimum performance it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using  fl exible venting.  For safe and proper operation of the fi replace, follow the venting instructions exactly. HORIZONTAL TERMINATION:  A clearance to combustibles of 2" must be maintained during the fi rst 24” of venting  when penetrating combustible walls.  The fi restop spacer (W500-0292) supplied with the unit should be used to  maintain this cl
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        11 USING FLEXIBLE VENT COMPONENTS Use only approved  aluminum fl exible liner kits marked: VERTICAL AIR TERMINAL INSTALLATION 1. Move the fi replace into position. 2. Fasten the roof support to the  a “Wolf Steel Approved Venting” as  roof using the screws provided.  identifi ed by the stamp only on the 7”  The roof support is optional. In this  case the venting is to be adequately  outer liner. supported using either an alternate  For safe and proper operation of the fi replace, follow the venting 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        12 FIREPLACE VENT CONNECTION 1. Install the 4” diameter aluminium fl exible liner to the  fi replace. Secure with 3 screws and fl at washers. Seal the  joint and screw holes using the high temperature sealant  FIGURE 20 (W573-0007 not provided). 2. Install the 7” diameter aluminium fl exible liner to the  fi replace. Attach and seal the joints. USING RIGID VENT COMPONENTS The vent system must be supported approximately every 3  EXTENDED HORIZONTAL AIR TERMINAL  feet for both vertical and horizontal r
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        13 6. Remove nails from the shingles, above and to the sides  GAS INSTALLATION of the chimney. Place the fl ashing over the air terminal and  Proceed once the vent installation is complete. slide it underneath the sides and upper edge of the shingles.  Ensure that the air terminal is properly centred within the fl ash- Note : All gas connections must be contained within  ing, giving a 3/4” margin all around. Fasten to the roof. Do NOT the fi replace when complete. 1.  The fi replace is designed to a
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        14 CLEARANCE TO COMBUSTIBLES FRAMING It is best to frame your fi replace after it is positioned and the  MAINTAIN THESE MINIMUM CLEARANCES TO COM- vent system is installed. Use 2x4’s and frame to local build- BUSTIBLES: ing codes. Fireplace framing   - 0” to stand-offs (top, rear & sides) Note: In order to avoid the possibility of exposed insulation  Fireplace fi nishing - 4” to sides of fi replace opening. 3 or vapour barrier coming in contact with the fi replace body,                              
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        O GAS VALVE N 15 MANTLE CLEARANCES Combustible mantle clearance  can vary according to the FIRESTOP mantle depth. Use the graph  SPACER 2" to help evaluate the clearance  needed. STUD 1" GAP FROM INSULATION SLEEVE 2" GAP FROM VENTING FIGURE 32 INSULATION 2" SLEEVE 6" MANTLE 13 STAND OFF M H 12 5" SPACER TOP OF 4" A E 11 3" N I 10 2" T G UNIT 11" 9" 9 L H 12" 10" 8" 8 E T 7 0 12 34 5 6 7 TOP OF MANTLE WIDTH FIREPLACE OPENING ELECTRICAL CONNECTION Do NOT use the fi replace if any part has been unde
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        16 FINISHING / SERVICING OPTIONAL FRONT REMOVAL BOWL AND BURNER REMOVAL    1a. Rectangular Front Removal Start by sliding the bowl forward until it clears the burner then  Pull on the top of the optional front away from the fi replace until lift from the fi rebox.  Remove the 2 screws located behind  the burner then lift up off the orifi ce and out.  Then using a  the male portion of the latch disengages. Tilt forward slightly  fl at head screw driver remove the curved decorative panel.   and lift f
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        17 4. After rocks have been placed on the bowl, add the  BLOWER REPLACEMENT remaining rock by inserting the pin into the hole shown in  Fig 40. Your       comes equipped with a heat circulating blower.  The blower is pre-wired and is controlled by the remote con- trol supplied with the unit. For control details, see operation.  FIGURE 39 Pg. 20. Drywall dust will penetrate into the blower bearings, caus- ing irreparable damage. Care must be taken to prevent  drywall dust from coming into contact
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        W O D N I W U R H T - E CONTROL PANEL E 18 BATTERY REPLACEMENT 1. Remove the optional front.  (Instructions on Pg. 17) 2. Tilt the control panel forward allowing access to the electode  box which is screwed to the base of the fi rebox.  (Fig. 43) FIGURE 43 BURNER CONTROL PANEL BASE ELECTRODE BURNER BOX BOTTOM (AA Battery  Required) CURVED  DECORATIVE  PANEL BURNER BOWL W415-0583 / B / 05.23.07 S                                                                                                       
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        19 TM NIGHT LIGHT REPLACEMENT TM Your    comes equipped with our Night Light . The  light has been pre-wired and is controlled from the remote  control. If in the event the lamp or lens needs to be replaced, follow  the instructions below. GASKET FIGURE 46 LENSE Unplug the wire harness  / transformer from the  FRAME junction box inside the  fi replace or turn off the  electrical breaker for the  Remove the four screws that secure the lens frame to the  fi replace.  top of the fi rebox.  FIGURE 44 T
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        20 HAND HELD REMOTE OPERATIONS 1. ON / OFF To turn the fi replace on press the ON / OFF button, the  fi replace will always light at maximum fl ame setting. Press  the ON / OFF button again to turn the fi replace off. 2. FLAME HEIGHT This function allows remote control of the fl ame height.  Check that the Remote Control is on, otherwise, turn on  the Remote Control and wait 5 seconds. Select the manual  fl ame height until the cursor (small triangle) is to the left of  the big fl ame. (Fig. 47)  Use t