Napoleon Fireplaces TUREEN GD82NT-T user manual

User manual for the device Napoleon Fireplaces TUREEN GD82NT-T

Device: Napoleon Fireplaces TUREEN GD82NT-T
Category: Fire Pit
Manufacturer: Napoleon Fireplaces
Size: 3.32 MB
Added : 11/1/2014
Number of pages: 31
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Napoleon Fireplaces TUREEN GD82NT-T. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Napoleon Fireplaces TUREEN GD82NT-T.

For your convenience

If looking through the Napoleon Fireplaces TUREEN GD82NT-T user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Napoleon Fireplaces TUREEN GD82NT-T on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Napoleon Fireplaces TUREEN GD82NT-T to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Napoleon Fireplaces TUREEN GD82NT-T User manual - Online PDF
Advertisement
« Page 1 of 31 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Napoleon Fireplaces TUREEN GD82NT-T but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Napoleon Fireplaces TUREEN GD82NT-T. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

1
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
INSTALLATION AND
OPERATION INSTRUCTIONS
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
GD82NT-T
NATURAL GAS
GD82PT-T
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING: If the information in these
instructions are not followed exactly, a fire
or explosion may result causing property
damage, persona

Summary of the content on the page No. 2

2 TABLE of CONTENTS TM PG 2-5 INTRODUCTION 19 NIGHT LIGHT REPLACEMENT Warranty Dimensions 19-23 OPERATION / MAINTENANCE General Instructions Time Out General Information Fireplace Operation Care of Glass & Plated Parts Hand Held Remote Operation Dip Switch Number Chart 5-9 VENTING Operating Instructions Vent lengths Venting Specifi cations Air Terminal Locations 24 ADJUSTMENTS Pilot Burner Adjustment 10-15 INSTALLATION/FRAMING Venturi

Summary of the content on the page No. 3

3 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete fi replace is thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the qual

Summary of the content on the page No. 4

4 FIGURE 1 58" 46" 3 17 /4" 5 37 /8" 4" DIA. 7" DIA. 1 22 /8" 21" 5" 7 13 /8" 2" 7 /8" 7 8 /8" 24" 14" 28" 28" Under extreme vent confi gurations, allow several minutes GENERAL INSTRUCTIONS (5-15) for the fl ame to stabilize after ignition. THIS GAS FIREPLACE SHOULD BE INSTALLED AND SER- Provide adequate ventilation and combustion air. VICED BY A QUALIFIED INSTALLER to conform with local Provide adequate accessibility clearance for servicing and codes. Installation practices vary from region

Summary of the content on the page No. 5

5 and fueled with natural gas. This fi replace may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited The inner stainless steel looking fi rebox back will discolour by local codes. with heat, turning a light brown, straw like colour that is to be This fi replace is only for use with the type of gas indicated considered normal. on the rating plate. This fi replace is not convertible for use with other gases, unless a certifi ed kit is used. CARE

Summary of the content on the page No. 6

6 DEFINITIONS ELBOW VENT LENGTH VALUES feet inches for the following symbols used in the venting calculations 1° 0.03 0.5 and examples are: 15° 0.45 6.0 > - greater than 30° 0.9 11.0 > - equal to or greater than 45° 1.35 16.0 < - less than 90°* 2.7 32.0 < - equal to or less than H - total of both horizontal vent lengths (H ) and offsets T R (H ) in feet O * the fi rst 90° offset has a zero value and is shown in the H - combined horizontal vent lengths in feet R formula as

Summary of the content on the page No. 7

7 TOP EXIT / HORIZONTAL TERMINATION V = V = 6 ft when (H ) > (V ) 1 T T T H = 3 ft 1 Simple venting confi guration (only one 90° elbow) H = 5 ft 2 H = H + H = 3 + 5 = 8 ft R 1 2 H = .03 (two 90° elbows - 90°) = .03(180° - 90°) = 2.7 FIGURE 6 O ft H = H + H = 8 + 2.7 = 10.7 ft T R O See graph to determine the required verti- H + V = 10.7 + 6 =16.7 T T cal rise V for the required horizontal run T Formula 1: H < 4.2 V H . T T T 4.2 V = 4.2 x 6 = 25.2 ft T 10.7 < 25.2 Formula 2: H

Summary of the content on the page No. 8

8 TOP EXIT VERTICAL TERMINATION REQUIRED VERTICAL when (H ) < (V ) T T RISE IN FEET See graph to V determine the T required vertical rise HORIZONTAL VENT RUN PLUS OFFSET IN V for the required T FEET H T horizontal run H . T The shaded area within the lines represents ac- ceptable values for H and V . T T For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply: Formula 1: H < V T T Formula 2: H + V < 40 feet T T

Summary of the content on the page No. 9

9 FIGURE 12 W415-0583 / B / 05.23.07

Summary of the content on the page No. 10

10 INSTALLATION WALL AND CEILING PROTECTION For optimum performance it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using fl exible venting. For safe and proper operation of the fi replace, follow the venting instructions exactly. HORIZONTAL TERMINATION: A clearance to combustibles of 2" must be maintained during the fi rst 24” of venting when penetrating combustible walls. The fi restop spacer (W500-0292) supplied with the unit should be used to maintain this cl

Summary of the content on the page No. 11

11 USING FLEXIBLE VENT COMPONENTS Use only approved aluminum fl exible liner kits marked: VERTICAL AIR TERMINAL INSTALLATION 1. Move the fi replace into position. 2. Fasten the roof support to the a “Wolf Steel Approved Venting” as roof using the screws provided. identifi ed by the stamp only on the 7” The roof support is optional. In this case the venting is to be adequately outer liner. supported using either an alternate For safe and proper operation of the fi replace, follow the venting

Summary of the content on the page No. 12

12 FIREPLACE VENT CONNECTION 1. Install the 4” diameter aluminium fl exible liner to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using the high temperature sealant FIGURE 20 (W573-0007 not provided). 2. Install the 7” diameter aluminium fl exible liner to the fi replace. Attach and seal the joints. USING RIGID VENT COMPONENTS The vent system must be supported approximately every 3 EXTENDED HORIZONTAL AIR TERMINAL feet for both vertical and horizontal r

Summary of the content on the page No. 13

13 6. Remove nails from the shingles, above and to the sides GAS INSTALLATION of the chimney. Place the fl ashing over the air terminal and Proceed once the vent installation is complete. slide it underneath the sides and upper edge of the shingles. Ensure that the air terminal is properly centred within the fl ash- Note : All gas connections must be contained within ing, giving a 3/4” margin all around. Fasten to the roof. Do NOT the fi replace when complete. 1. The fi replace is designed to a

Summary of the content on the page No. 14

14 CLEARANCE TO COMBUSTIBLES FRAMING It is best to frame your fi replace after it is positioned and the MAINTAIN THESE MINIMUM CLEARANCES TO COM- vent system is installed. Use 2x4’s and frame to local build- BUSTIBLES: ing codes. Fireplace framing - 0” to stand-offs (top, rear & sides) Note: In order to avoid the possibility of exposed insulation Fireplace fi nishing - 4” to sides of fi replace opening. 3 or vapour barrier coming in contact with the fi replace body,

Summary of the content on the page No. 15

O GAS VALVE N 15 MANTLE CLEARANCES Combustible mantle clearance can vary according to the FIRESTOP mantle depth. Use the graph SPACER 2" to help evaluate the clearance needed. STUD 1" GAP FROM INSULATION SLEEVE 2" GAP FROM VENTING FIGURE 32 INSULATION 2" SLEEVE 6" MANTLE 13 STAND OFF M H 12 5" SPACER TOP OF 4" A E 11 3" N I 10 2" T G UNIT 11" 9" 9 L H 12" 10" 8" 8 E T 7 0 12 34 5 6 7 TOP OF MANTLE WIDTH FIREPLACE OPENING ELECTRICAL CONNECTION Do NOT use the fi replace if any part has been unde

Summary of the content on the page No. 16

16 FINISHING / SERVICING OPTIONAL FRONT REMOVAL BOWL AND BURNER REMOVAL 1a. Rectangular Front Removal Start by sliding the bowl forward until it clears the burner then Pull on the top of the optional front away from the fi replace until lift from the fi rebox. Remove the 2 screws located behind the burner then lift up off the orifi ce and out. Then using a the male portion of the latch disengages. Tilt forward slightly fl at head screw driver remove the curved decorative panel. and lift f

Summary of the content on the page No. 17

17 4. After rocks have been placed on the bowl, add the BLOWER REPLACEMENT remaining rock by inserting the pin into the hole shown in Fig 40. Your comes equipped with a heat circulating blower. The blower is pre-wired and is controlled by the remote con- trol supplied with the unit. For control details, see operation. FIGURE 39 Pg. 20. Drywall dust will penetrate into the blower bearings, caus- ing irreparable damage. Care must be taken to prevent drywall dust from coming into contact

Summary of the content on the page No. 18

W O D N I W U R H T - E CONTROL PANEL E 18 BATTERY REPLACEMENT 1. Remove the optional front. (Instructions on Pg. 17) 2. Tilt the control panel forward allowing access to the electode box which is screwed to the base of the fi rebox. (Fig. 43) FIGURE 43 BURNER CONTROL PANEL BASE ELECTRODE BURNER BOX BOTTOM (AA Battery Required) CURVED DECORATIVE PANEL BURNER BOWL W415-0583 / B / 05.23.07 S

Summary of the content on the page No. 19

19 TM NIGHT LIGHT REPLACEMENT TM Your comes equipped with our Night Light . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below. GASKET FIGURE 46 LENSE Unplug the wire harness / transformer from the FRAME junction box inside the fi replace or turn off the electrical breaker for the Remove the four screws that secure the lens frame to the fi replace. top of the fi rebox. FIGURE 44 T

Summary of the content on the page No. 20

20 HAND HELD REMOTE OPERATIONS 1. ON / OFF To turn the fi replace on press the ON / OFF button, the fi replace will always light at maximum fl ame setting. Press the ON / OFF button again to turn the fi replace off. 2. FLAME HEIGHT This function allows remote control of the fl ame height. Check that the Remote Control is on, otherwise, turn on the Remote Control and wait 5 seconds. Select the manual fl ame height until the cursor (small triangle) is to the left of the big fl ame. (Fig. 47) Use t


Alternative user manuals
# User manual Category Download
1 Napoleon Fireplaces TUREEN GD82NT-T User manual Printer Accessories 0
2 Napoleon Fireplaces GLVF18P User manual Fire Pit 0
3 Napoleon Fireplaces GI3016-P User manual Fire Pit 2
4 Napoleon Fireplaces GD82PT-PA User manual Fire Pit 0
5 Napoleon Fireplaces GLVF24P User manual Fire Pit 0
6 Napoleon Fireplaces GLVF24N User manual Fire Pit 0
7 Napoleon Fireplaces GLVF30N User manual Fire Pit 0
8 Napoleon Fireplaces GLVF18N User manual Fire Pit 0
9 Napoleon Fireplaces GLVF30P User manual Fire Pit 0
10 Napoleon Fireplaces TUREEN GD82PT-T User manual Fire Pit 0
11 Napoleon Fireplaces GD82NT-PA User manual Fire Pit 0
12 Aquatic Exotic Flames Natural Gas User manual Fire Pit 0
13 Athena Technologies A88028 User manual Fire Pit 0
14 Avalon Stoves Gas Stove & Fireplace User manual Fire Pit 2
15 Baxi Potterton 339 User manual Fire Pit 1
16 Blue Rhino WAD808WDNC User manual Fire Pit 1