ملخص المحتوى في الصفحة رقم 1 
                    
                        05-03-457   A029-OK.PDF
Instruction Manual 
P  O  R  T  A  B  L  E 
Air Conditioner 
         
Model No. WA-1300E Model No. WA-1310E
Model No. WA-1300H Model No. WA-1310H
It is important that you read these 
instructions before using your new 
purchase and we strongly 
recommend that you keep them in a 
safe place for future reference.                                                                                                                                                                 
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        05-03-457 A029-OK.PDF TABLE OF CONTENTS  THANK YOU   ENERGY SAVING TIPS………..……………………………………………….. 2 SPECIFICATIONS..……………………………………………………………….3 BEFORE USE……….……………………………………………………………. 4  PARTS………..…………………………………………………………………….5 INSTALLATION.…………………………………………………………………...6 MOUNTING OF THE EXHAUST PIPE ………………………………………... 7  INSTALLATION OF THE CARBON FILTER…………………………………... 8 OPERATION ……………………………………………………………………… 9 NOTICE.…………………………………………………………………………..12 DRAINAGE………………………………………………………………………. 13  MAINTENANC
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        05-03-457 A029-OK.PDF THANK YOU  Thank you for choosing the portable air conditioner from SPTUSA, a leading  brand in indoor air treatment. We would like you to enjoy the many benefits  this unit offers, so please take the time to read this manual carefully and take  full advantage of the many advanced features that your SPTUSA Air  Conditioner offers you.  SPTUSA specialize in complete indoor environment control, manufacturing  world-class air conditioners, dehumidifiers and air purifiers with 
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        05-03-457 A029-OK.PDF SPECIFICATION WA-1300E WA-1300H Model no. WA-1310E WA-1310H Cooling capacity 13000 BTU/hr 13000 BTU/hr  13000 BTU/hr  Heating capacity - Power/Ampere 1071W/ 9.4A 1071W/ 9.4A consumption for cooling*  Power/Ampere - 1071W/ 9.4A  consumption for heating* 3 3 Air volume (max. speed) 580m/h 580m /h Humidity removal capacity              98 Pts/day                 98 Pts/day Recommended room size 420sq.ft. 420sq.ft. Power supply 115V/60Hz/1phase Compressor Rotary  Refrigerant R-
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                         20" 05-03-457 A029-OK.PDF BEFORE USE  Important!  Transport the unit in an upright position only or leave in upright position  for at least 2 hours before use. Keep at least 20 inches away from the  wall. (Figure 1 & 4)   Always place the unit on an even surface.   Make sure the unit is connected to a correctly grounded power supply (refer to the rating label located at the back of the unit).  FIG. 1  An opening in a window or wall is required to accommodate the  exhaust hose (kit supplied)
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        05-03-457 A029-OK.PDF PARTS Front Back         FIG. 5  FIG.6  1. Control Panel 5. Air filter  2. Air outlet 6. Air inlet  3. Carrying handle 7. Exhaust air outlet  4. Caster 8. Water stopper / drainage point 9. Cord storage  Accessories 10. Inward adaptor - for insertion over hose  and connect to back of the air conditioner.  11. Round connector - for insertion over hose   and into foam strip (or into hole in the   wall/window). 12. Exhaust hose:   Length: 14”-60”  Diameter: 4.75”  13. Round cap
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        05-03-457 A029-OK.PDF INSTALLATION EXHAUST PIPE INSTALLATION  The unit is a portable air conditioner that may be moved from room to room.  1. Using the foam strips / Window installation  Used to cover the window gap and can be cut to size if necessary.  Foam strips    FIG.8  • Attach hose to unit and insert other end through the foam strip. • Attach Round Connector (part 11) by turning clock-wise.  • Insert strip into window gap as shown and slide window across so that foam is held  securely.  T
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        05-03-457 A029-OK.PDF Mounting of the exhaust pipe  • Use only the hose provided. Attach  hose to back of unit by connecting  the adaptor.  • Avoid kinks and sharp bends in the  exhaust hose as this will cause  expelled moist air to build up and  the unit will overheat and shut  FIG.11 down.  Fig 11 & 12 shows correct  position • The hose may be extended from 12 inches to 59 inches but for maximum efficiency use the  shortest length possible.  FIG.12 FIG.13 WARNING! The length of the exhaust pip
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        05-03-457 A029-OK.PDF Installing the Carbon Filter  1. Remove the filter frame from the  unit.   2. Unclip and remove one side of the  frame. 3. Remove the active carbon filter  from its plastic bag.  4. Insert the active carbon filter into  the filter frame.  5. Replace the other half of the  frame. 6. Re-insert the filter frame inside the  unit. 7. It is recommended to replace the  carbon filter every 3 to 6 months.  Replacement Filter:  FIG. 15 To purchase Replacement  Filters for this unit, 
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        05-03-457 A029-OK.PDF OPERATION Control panel                                        FIG.17 1. Automatic mode indicator 14. UV-Tio2/Ionizer switch (only for models  2. Cooling mode indicator with UV-Tio2 or Ionizer function)  3. Fan mode indicator 15. Sleep function button   4. Heating mode indicator (for cool & heat 16. “Temperature up” button  models only). 17. “Temperature down” button  5. Low ventilation indicator  18. LCD display  6. Medium ventilation indicator 19. ON/OFF (power) button  7
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        05-03-457 A029-OK.PDF Auto Mode  When this mode is selected, the unit is preset to the following temperature settings and unit will  only start to:   Cool when room temperature is higher than 75°F   Heat when room temperature is lower than 68°F  (WA-1300H &WA-1310H models only)  If room temperature is between 68°F and 75°F, unit will stay in Fan mode. Again, when in Auto  Mode, the temperature settings cannot be changed.  Setting temperature  o o The pre-setting temperature of this machine is:
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        05-03-457 A029-OK.PDF Setting ventilation speed  1. Press SPEED button to choose the desired ventilation speed: High, Medium or Low. The  indicator respective speed will light on at the same time.  2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to  the ambient temperature (the related indicators will light on), at this time, this button is  invalid. Setting timer  1. Pressing the TIMER button while unit is operating will set desired operating hours (
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        05-03-457 A029-OK.PDF Regulating air flow direction  Adjust louver on the air vent horizontally to  control air flow direction. FIG. 19  NOTICE !  The compressor will start approximately 3 minutes after the compressor is turned off (this will help prolong the life of the compressor). After switching the unit off, please wait at  least 3 minutes before turning the unit back on.   The cooling system will switch off if the room temperature is 1ºF lower than set. The fan,  however, keeps working at
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        05-03-457 A029-OK.PDF  .DRAINAGE During the process of cooling or heating, some water will be extracted from the air.  Most of this  water is used to cool the cooling coils and make the unit run more efficiently. This is a feature not  found in most other portable air conditioners.  If the unit is operated in a VERY HUMID  environment, water will start to collect in the built-in water reservoir.  When the water tank  becomes full, the compressor and fan will stop. The water full indicator (W.F.)
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        05-03-457 A029-OK.PDF Original drain  NOTE Extended  The drain tube must be at or below the  drain tube  outlet level. (OD: 3/4in)  Water Full (full water) indicator will not  FIG.23 function in this mode of drainage.   If you wish to extend the water tube, please  connect with another tube (outside  diameter 3/4"). Special caution for heating function!  While using the heating function, please note:  1. Install the exhaust hose to exhaust cool air  outdoors. (Please refer to page 6 for  inst
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        05-03-457 A029-OK.PDF .MAINTENANCE Always unplug the unit before cleaning and maintenance. Cleaning the Housing Use a soft, damp cloth to wipe the body clean.  Never use strong chemicals, oil-based products, detergents, chemically treated cloths  or other cleaning solutions. These could possibly damage the cabinet.  Cleaning the Filter First remove the black active carbon filter from the frame, tap lightly to remove loose dust  and dirt.  Use a vacuum cleaner or tap the white filter lightly to r
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        05-03-457 A029-OK.PDF .TROUBLE SHOOTING   Is the machine plugged in?   Is the main power supply on?   Is room temperature within working  The unit doesn’t run or only runs in fan  temp range?  mode  Is unit set in Auto mode? Select Cool or  Heat mode and set to proper  temperature.  Is there direct sunlight? Please draw  curtains and blinds.   Are there too many windows or doors  The unit seems to do little open?  Are there too many people in the room?  Is there something in the room tha
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        05-03-457 A029-OK.PDF .DEFECTIVE NOTICE  If this product is defective or not working properly  Please DO NOT return to your retail store Please contact us directly with any Service or Technical Assistance  Contact us toll free at:  1-800-330-0388 REPLACEMENT FILTERS: To purchase Replacement Filters for this unit, contact SPTUSA at  1-800-330-0388 and request model number WA-1300F. 17                                                                                                                  
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        05-03-457 A029-OK.PDF Portable Air Conditioner / Heater  Your Guarantee If this product is found to be faulty as a result of faulty materials or  workmanship within one year from date of purchase, it will be repaired or  replaced free of charge. This guarantee is subject to the following terms:  SPTUSA, must be notified of the fault.  Proof of purchase must be presented to SPTUSA’s nominated representative.  The warranty will be void if the product is modified, misused or repaired by an unauthor
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        05-03-457 A029-OK.PDF SAFETY POWER SUPPLY CORD:  This Portable Air Conditioner is provided with a Leakage Current Detection and  Interruption circuit (LCDI) built into the plug of the power supply cord.  This device provides protection to reduce the risk of fire due to arcing faults in the  power-supply cord. Each time before using the Portable Air Conditioner, follow the  “plug Testing Instructions” given below to ensure that the LCDI circuit is functioning  properly.  PLUG TESTING INSTRUCTIONS