MODEL CMA-180 
 
 
Installation & Operation  
 
Rev 2.03 
 
 
 
  
CMA DISHMACHINES 
12700 KNOTT AVENUE 
GARDEN GROVE, CALIFORNIA 92841 
800-854-6417 
FAX 714-895-2141
 www.cmadishmachines.com                                                                                                                                                                                                                                                                                                            
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                          Table of Contents  CMA-180    1. SPECIFICATIONS................................................................................................. 2  1.1 CMA-180/CMA-180T.................................................................................................................... 2  1.1. CMA-180/CMA-180T.................................................................................................................... 3  2. GETTING STARTED...................................................
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                          1. Specifications   Metric  Equivalent  1.1 CMA-180/CMA-180T  WATER CONSUMPTION    PER RACK .96 GAL. (3.6 L)  PER HOUR  52 GAL. (197 L)  OPERATING CYCLE    WASH TIME-SEC 49 49  RINSE TIME-SEC 12 12  TOTAL CYCLE 61 MIN. 61 MIN.  OPERATING CAPACITY    RACKS PER HOUR (NSF rated) 60 60  WASH TANK CAPACITY 8 GAL. (30.3 L)  PUMP CAPACITY 68 GPM (257 LPM)  WATER REQUIREMENTS    WITHOUT BOOSTER HEATER 180°F (82°C)  WITH BOOSTER HEATER        140°F                 (60°C)  WATER INLET            ¾”     
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                              1.1. CMA-180/CMA-180T    VOLTS PHASE AMPS  ELECTRICAL RATING  WITHOUT BOOSTER 208 1 28/35  240 1 30/38     208 3 20/24  240 3 21/26               ELECTRICAL RATING 208 1 71/78  240 1 80/88  WITH BOOSTER   208 3 45/49  240 3 50/55          SHIPPING WEIGHT  332#  WITHOUT BOOSTER  375#  WITH BOOSTER  MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page  3                                                                                                                                           
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                          2. Getting Started  2.1. Introduction to CMA-180    The CMA-180 is a hot water sanitizing, single rack, door-type dishmachine.  It is a stand-alone  machine featuring a self-contained booster heater (optional).  The only external connections  necessary are power supply, water supply, drainpipe, and chemical dispensers.  The machine  utilizes recirculated wash water and fresh water final rinse.  The CMA-180 can be converted both  as a straight through and corner with a door handle kit.     Oper
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                          2.2. Receiving and Installation    Step 1:  Remove packaging material.  Step 2:  Remove service manual and machine legs from inside the wash tank.  Step 3:  Install legs into dishmachine leg lockets and adjust the feet.  Set the                machine in place.  Level the machine side – to – side and front – to –                back.      Step 4:  It is recommended that a distance of at least eight inches (8”) be      between the table scrap sink and the dishmachine.       * 2.2.1. Electrical 
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                          flexibility to permit the machine to be moved for cleaning without having to  disconnect any wiring.  ii. Run your dispenser wires through the conduit to the control box.   iii. Run your probe wires to the control box.  iv. With the machine’s power “OFF”, connect your detergent and rinse dispenser  wires to the red and blue terminals of the power block supplied inside the control  box.  The table that follows lists the function of each conductor of the multi- conductor electrical cable.    Wir
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                            2. Remove the plug from the mixing chamber located by the vacuum breaker on the  back of machine; and install the rinse injection fitting (supplied with your  dispenser).    3. A 7/8” detergent injection hole is provided in the back of the wash tank.  Remove  the S.S. plug and install the detergent fitting (supplied with your dispenser).    4. A 7/8” chemical probe hole is provided in the front of the wash tank heater just  below hi limit switch. Insert the probe into the hole from inside th
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                          2.2.4. Exhaust Fan Control    MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page  8                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                          2.2.5. Water Tempering Kit      MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page  9                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                            2.2.6. Installation Checklist      Dishmachine checked for concealed damage.    Hot water supply is 140° (60°C)    Incoming water supply line is ¾”.    Incoming water supply is 6 gpm minimum capable at 20 psi flow pressure.    Machine circuit breaker is properly sized.    Service voltage and phase type are correct to machine data plate.    High leg of voltage is connected to L2 (three-phase).    Dishmachine is properly ventilated.    Floor drain plumbing is installed with air gap.    Dishmac
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                          2.2.7. Machine Start-Up Procedures    1. Open doors and install the overflow & scrap trap on the right side of the machine.  2. Place the scrap baskets over the wash tanks.  3. Secure the wash & rinse arms and check the free-spin.    4. Open the control cover and select ‘normal” toggle switch position.  5. Adjust the rinse pressure to 20 psi flow pressure using the regulator and the gauge.  a. Turn the power switch to the “Off” position.  b. Close doors and open the hand-operated fill valve un
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                          2.2.8. Electrical Requirements    The CMA-180 comes standard factory, wired for 3-phase operation.  Check the electrical data  plate to confirm this.  If the account requires 1 phase, refer to “Electrical Requirements”, Section  1-A, for proper wiring instruction for conversion.  Also check the wiring diagram to properly wire  the terminal power block, tank heater, and booster heater for 1 phase (or 1B diagram below).    SINGLE PHASE POWER    NOTE:  80 amp service is required when CMA-180 is w
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                          3. Wiring Options    3-Phase and 1 Phase  Wiring Options    Single-Source   Single-Source  Single-Source Two-Source Single-Source  220V 3-Phase   220V 3-Phase 220V 1-Phase 220V 1-Phase 220V 1-Phase  (20 amp/12 g*)   (50 amp/8 g*) (80 amp/4 g*) (50 amp/8 g*) (30 amp/10 G*)  (30 amp/10 g*)    (without Booster)                 (without booster)                      *g=gauge       DISPENSER HOOK-UP  1. The power signal is 208/230 volts.  The power block is labeled inside the control box.   Conduit
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                          4. Quick service guide    MODEL: CMA 180 HIGH TEMP  TECHNICAL ISSUE CAUSE SOLUTION  Door magnetic reed switch problem Faulty magnetic reed switch Check wire connections inside control box        Contact factory for new retrofit, corner P/N  00566.10 straight P/N 00566.20    Door mechanical switch problem Switch alignment issue Align switch    Switch button broke Replace switch, P/N00562.00    Delimer switch is in OFF position Flip to NORMAL position    Loose wire connections Check and crimp co
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                          5. INITIAL PARTS KIT P/N 1100.17       P/N DESCRIPTION NO. REQ’D    00121.18    CMA-180 Drain Stopper O Ring 1    00200.10    Pump Assy 110/220V 60 Hz (Open) 1  00206.00    Pump Seal Kit 1    00302.19    CMA-180 Buna Gasket (#302.17) 1    00304.17    CMA-180 Wash Spray Arm 1    00304.19    CMA-180 Rinse Arm W/Bearing 1   00308.17    CMA-180 Rinse Arm SS End Plug 1  00308.50    Spray Arm End Plug SS 1    00363.00    Spray Base Lock Pin 1    00404.85    Contactor 208.240V 20AMP 1    00405.00    
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                          6. Auto-Fill Solid State Timer    Pre-selected delay period can be adjusted by  turning securely small flat screwdriver. Since  the range of this solid state timer is from 6  seconds to 240 seconds, you should adjust  delay by small increment.  Removal of input power will reset the control.         AUTO-FILL SWITCH 6 L2 T2 WATER L1 T1 SOLENOID VALVE 23 1   MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page  16 WASH PUMP CONTACTOR                                                              
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                          7. Wire Diagram          MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page  17                                                                                                                                                                                                                                                                                                                                                                                                                                
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                          8. Wire Diagram for CMA-180 Booster Only    L2 T2 GROUND RINSE SIGNAL { DETERGENT { L1 T1 L3 T3 GND L3 L2 T2 L2 L1 T1 L1 L3 T3 L2 T2 T1 L1 HI LIMIT SWITCH 5kW WASH TANK ADJ. 12kW PUMP THERMOSTAT HEATER MOTOR BOOSTER HEATER   MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page  18 BOOSTER HEATER WASH PUMP HEATER CONTACTOR CONTACTOR CONTACTOR