Inhaltszusammenfassung zur Seite Nr. 1 
                    
                         
Owner’s Manual 
 
Keep with machine for reference 
 
 
 
 
 
MODEL CMA-180UC 
 
INSTALLATION & OPERATION 
Rev 1.15 
 
          
 CMA DISHMACHINES 
12700 KNOTT AVENUE 
  GARDEN GROVE, CALIFORNIA 92841 
800-854-6417 
FAX 714-895-2141
 
 www.cmadishmachines.com                                                                                                                                                                                                                                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        TABLE OF CONTENTS  MODEL CMA-180UC  1. SPECIFICATIONS ........................................................................................ 2  1.1. CMA-180UC ......................................................................................................................... 2  1.2. CMA-180UC OPERATIONAL CYCLE...................................................................................... 3  2. GETTING STARTED..........................................................................
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                          1. Specifications  METRIC  EQUIVALENT  1.1. CMA-180UC  WATER CONSUMPTION    PER RACK .86 GAL. (3.25 L)  PER HOUR 20.6 GAL. (77.8 L)  OPERATING CYCLE    WASH TIME-SEC 94 94  RINSE TIME-SEC 16 16  DWELL TIME-SEC 10 10  TOTAL CYCLE 2 MIN. 2 MIN.  OPERATING CAPACITY    RACKS PER HOUR 30 30  WASH TANK CAPACITY 2.5 GAL. (9.46 L)  PUMP CAPACITY 38 GPM (144 LPM)  WATER REQUIREMENTS 140°F (60°C)  WATER INLET ½” 1.27cm  DRAIN CONNECTION 1” 2.54cm  2 RINSE PRESSURE SET 20 PSI ±5 PSI 1.41 kg/cm    CYCLE T
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                          1.2. CMA-180UC Operational Cycle    The CMA-180UC Operational Cycle has a total cycle time of 2 minutes (120 seconds).  The  Timing Diagram and the steps listed below detail the individual functions that are executed  during each Operational Cycle.    Seconds:   0 10 20 30 40 50 60 70  80 90 100 110 120                           Instant                          Start Relay                                                    Cam Timer  Motor Cam                                                   
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        Getting Started   2. Getting Started  2.1. Introduction to CMA-180UC  The CMA-180UC is a hot water sanitizing, single rack, under-counter dishmachine.  It is a  standalone machine featuring a self-contained booster heater.  The only external connections  necessary are power supply, water supply, drainpipe, and optional chemical dispensers.  The  machine uses re-circulated wash water and fresh water final-rinse.  Operation of the CMA-180UC is extremely user friendly.  To initially fill the machin
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                          2.2. Receiving and Installation  The dishwasher is shipped from the factory in a corrugated box on a wooden pallet.  The  installation guidelines give a systematic procedure for setting up the machine.  Start by removing the packaging material.  Unwrap the machine and check for the following  component parts:  The Wash Tank Scrap Screen is shipped inside the wash cavity of the machine. This screen must  be in place during operation.  It has been designed to perform two basic functions:  1. Str
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                          1 2.2.3. NOVA Detergent and Rinse Dispenser (Optional) .  The NOVA Detergent and Rinse Dispenser has its own reference manual.   Familiarize yourself with the dispenser’s reference manual before proceeding with  installation.  1. The NOVA dispenser is pre-wired with a multi-conductor electrical cable that is to  be run through a conduit to the power block inside the control panel drawer.  Use  a ½” watertight conduit meeting all local and national codes.  A conduit fitting is  present on the b
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                            Brown (LIVE) wire      Multi-conductor cable  Rinse Signal wires (Blue terminals)  Detergent Signal wires  (Red terminals)  Black (Main Power)  Gray/Violet  (Main Power Neutral)  (Same terminal as rinse neutral) Note: Machine Neutral (White wires)    Figure 2.2.3 Note: In Figure 2.2.3 the machine’s wire harness was left out of the back of the  power block to more clearly show the dispenser wires.  2. Remove the plug from the mixing chamber located by the vacuum breaker on the  back of machin
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                            2.2.4. Safe Ttemp Feature  The CMA “SafeTtemp” feature assures the final rinse cycle is always at a consistent minimum of  180 degrees.  th How it works: the “SafeTtemp” function operates off the 5 cam (labeled “SafeTtemp”) on the  timer assembly. When the cam timer assembly completes the wash cycle, and approaches the  final rinse portion of the cycle, the “SafeTtemp” micro switch will drop into the cam slot and pause  cam timer assembly if the booster heater has not reached 180 degrees. Ma
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                            2.2.5. Water Tempering Kit    MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15 Page 9                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                          2.2.6. Booster Heater Setup  The booster tank must be filled with water before the heating element is energized.   For this reason the “High Limit Switch” has intentionally been activated at the factory  and will require resetting before the heating element will turn on.  Follow the procedure below to complete the initial installation:  1. Close the door on the machine.  2. Turn the Power switch to the "ON" position.  3. Hold the “FILL” switch in until water overflows into the scrap tray.  4. 
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        Operation    3. Operation  3.1. Initial Setup  3.1.1. Dema Valve and Dema Flow Disc (New Models).  New Dema Valve made of stainless steel is more compatible with various water  conditions. Dema Flow Disc has been placed on the exit side of the water valve.  The Flow Disc reduces pressure to the standard recommended 20 PSI.  3.1.2. Rinse Pressure Regulator (Old Models Prior January 2008).  The CMA-180UC requires a supply water input pressure of 24 PSI minimum.  This  pressure is then reduced by t
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        Operation   3.3. Operating and Cleaning Instructions                                                                                MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15 Page 12                                                                                                                                                                                                                                                                                                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        Operation   3.4. Preventive Maintenance Chart    MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15 Page 13                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        Operation   3.5. Quick service guide  MODEL:  CMA 180UC HIGH TEMP UNDER COUNTER        TECHNICAL ISSUE CAUSE SOLUTION  Pressure regulator is not set properly Set regulator to 18-20 psi     Faulty rinse micro switch Replace micro switch, P/N 00411.00     Drain hose elevated too high  Must be lowered to goose neck level  Scrap trap over flows    Obstruction in drain hose Check hose & clean    Scrap exit screen Clean exit screen    Faulty drain pump  Replace pump, P/N 15503.00    Machine not level 
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        Operation   3.6. Troubleshooting    PROBLEM LIKELY CAUSE SOLUTION  Machine inoperative Power off at circuit breaker Reset circuit breaker  Defective power switch Replace power switch  P/N: 15521.50  Motor inoperative Door is open Close door  Control panel is pulled out Secure control panel  Defective reed switch Replace reed switch  P/N: 00557.55  Defective timer assembly Replace timer assembly*  P/N: 14408.80  Defective pump motor contactor Replace contactor  P/N: 15504.00  Defective motor Repl
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        Operation   PROBLEM LIKELY CAUSE SOLUTION  Low heat during operation Low incoming water temperature  Turn up supply water heater  (below 140° F)  Insulate supply water pipe  Thermostat out of adjustment Adjust thermostat  Cold water mixing with supply Isolate hot water from cold  water  Defective heater Replace heater  P/N: 15517.00  Low rinse water pressure Pressure regulator out of Adjust pressure regulator  adjustment  Defective pressure gauge (actual Replace pressure gauge  pressure is okay)
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        Operation   PROBLEM LIKELY CAUSE SOLUTION  Start switch requires > 1 Defective (Instant Start) ice cube Replace ice cube relay   second activation to run relay  P/N: 00631.00  cycle  Activating fill switch does Defective drain/fill switch Replace drain/fill switch  not fill machine  P/N: 15522.00  Defective water solenoid valve Replace water solenoid valve  P/N: 03603.10  Fill (rinse water) won’t shut Defective water solenoid valve Replace water solenoid valve  off  P/N: 03603.10  Defective drai
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                           4. Parts Kit  4.1. Initial Parts Kit (P/N 1100.66)    P/N DESCRIPTION Qty  15504.00 Motor Contactor, 2-Pole 20 Amp 1  15504.50 Heater Contactor, 2-Pole 35 Amp 1  00501.00 2-Minute Timer Motor 1  00631.00 Ice Cube Relay 120 V 1  15521.00 Rocker Switch Start Momentary 1  15522.00 Rocker Switch Drain/Fill 1  15521.50 Rocker Switch Power Maintained 1  00557.55 Reed Switch 1  03623.00 1/2” Vacuum Breaker Repair Kit – Watts 1  00707.00 1/2” Water Solenoid Repair Kit – J/E 1  04103.00 L1X/L1-C Drain
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        Parts Manual    4.2. Optional Drain Pump Kit          ITEM NO. ITEM NO.    P/N DESCRIPTION P/N DESCRIPTION  NO. REQ’D NO. REQ’D 1 1 15503.00 Drain Motor Ultra Jet for CMA-180UC 6 4 03101.00 Hose Clamp 1”  2 2 00432.50 Twist Tie 7 1 15603.00 Drain Line Gooseneck  3 1 15601.10 Black Drain Hose 1" ID X 3 1/2" 8 2 03801.10 10-32 SS Nut  4 1 15601.50 Drain Hose 1" ID, 6 ft 9 2 04806.00 #10 Brass Washer  5 1 15601.60 Robber Hose 90 Deg.      MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15 Pa