Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        Installation Manual
Caravan roof gland 
HDZ 100
Protective casing for cable interfaces 
on the caravan roof for Kathrein 
rotary antenna systems type CAP series                                                                                                                                                                                                                                                                                                                                                    
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        CONTENTS CONTENTS ............................................................................................................................... 2 FOREIGN LANGUAGE INSTALLATION MANUALS/SERVICE ...................................................... 3 ADDRESS OF THE SERVICE CENTRE ..................................................................................... 3 HDZ 100 COMPONENTS/SCOPE OF SUPPLY ............................................................................ 4 HDZ 100 SCOPE OF 
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        FOREIGN LANGUAGE INSTALLATION MANUALS/SERVICE Dear Customer, Chère Cliente, Cher Client, Gentile cliente, Estimado cliente, GB You can obtain an English version of our installation instructions from our representatives in your country  (http://www.kathrein.de/include/kontakte_groups_eng.cfm?kontinent=1&gruppe=SAT) or download one  from our homepage (http://www.kathrein.de/en/sat/products/englisch.htm). ADDRESS OF THE SERVICE CENTRE ESC Electronic Service Chiemgau GmbH Bahnhofstraße 108 83224 Gra
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        HDZ 100 COMPONENTS/SCOPE OF SUPPLY • Protective casing for cable interfaces on the  caravan roof for Kathrein rotary antenna systems  type CAP series • Capable of accepting up to two RF cables  (Ø 5 mm) and one DC cable (Ø 6.5-7 mm) • The cables can optionally be fed downwards from  the HDZ 100 casing into the vehicle interior or out  from the casing to other points on the vehicle roof • Functionally appropriate sealing of the roof opening  after disconnecting the cable connections when  removin
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        PROPER USE PROPER USE (USE FOR THE INTENDED PURPOSE) The HDZ 100 roof gland protects the cable connection point and the roof gland point when laying cables  from CAP systems on the caravan or mobile home roof. The gland seatings are designed for two cables (Ø 5 mm) and one cable (Ø 6.5-7 mm). Any use other than that specifi ed above will void the warranty or guarantee. The following circumstances result in the loss of all warranty and liability claims towards  the manufacturer: • Improper install
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        SAFETY INSTRUCTIONS - IMPORTANT NOTES Safety during installation work When carrying out installation work in locations where there is a risk of falling, take appropriate  safety precautions, e.g. use of a working platform. Make sure that the vehicle roof is  suffi ciently strong and stable to carry out the installation work (risk of damage or collapsing  of roof). In case of doubt, contact a qualifi ed specialist dealer or the manufacturer of your vehicle  to fi nd an appropriate installation locat
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        SAFETY INSTRUCTIONS - IMPORTANT NOTES Cables Lay all cables such that nobody can tread on them or trip over them. When connecting the power cables (receiver and turntable) to the vehicle electrical supply, make sure  that the cable polarity is not reversed. If the cable polarity is reversed there is a risk of thermal overload and damage  to components when the equipment is powered up! If cable ducts are used to protect the cables, up to a size of 31 x 17 mm they can be concealed in the  recess i
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        INSTALLATION EXAMPLES BASIC VARIANTS Roof gland with cable interface   Roof gland without cable interface   Cable continuation with cable interface CAP 600  and  CAP 700 Note: For the CAP 600/700 units there are always  CAP 600  two cables emerging from the turntable. and  CAP 700 For the CAP 900 unit there are always three  cables emerging from the turntable. CAP 600  and  CAP 700 CAP 900 CAP 900    8                                                                                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        INSTALLATION AND CONNECTION REQUIRED TOOLS AND EQUIPMENT • Circular cutter, Ø 38 mm • Cross-head screwdriver for M4 screws • Power drill • Twist drill Ø 2.5 mm • Knife • Round fi le or emery paper ® • Sikafl ex 291 sealant (included in the CAP turntable scope of supply. Comply with the respective  safety instructions for the sealant) • If required for the type of installation selected: cable ducts (not included in the scope of supply) NECESSARY SPACINGS WHEN USING CABLE DUCTS Distance of the cable
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        INSTALLATION AND CONNECTION INSTALLATION STEPS ROOF GLAND VARIANT 1. In the centre of the intended position  of the cable outlet spigot, drill the  opening for the cable gland with a  circular cutter (Ø: 38 mm). Deburr the  hole with a round fi le or emery paper  (see illustration on the right). 2. Provisionally insert the casing lower  half into the drilled hole. 3. Mark out the positions of the three  fastening holes on the vehicle roof  (see illustration on the right). 4. At the marked positio
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        INSTALLATION AND CONNECTION to the substrate.  If the coat of paint is already loose or peeling, it must be removed down to a stable layer in the area  to which the adhesive will bond. If you have any doubts concerning the adhesive characteristics,  consult a paint and lacquer specialist, or the manufacturer of your vehicle. Under certain circumstances, it may be necessary for you to improve the adhesive properties of the roof  ® surface by pre-treatment with a cleaning agent available from spec
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        INSTALLATION AND CONNECTION 11. Use the plugs supplied to seal the  cable attachment points that are now  not required (see illustration on the  right).  Do not cut away any plugs that are  not required, you will need them  if you ever wish to remove the  turntable system. 12. Now place the cover on the casing  lower half and screw the two halves  together using the four screws pre- inserted in the cover (tightening  torque: M = 1-1.5 Nm). A CABLE CONTINUATION VARIANT 1. First cut the cylindrica
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        INSTALLATION AND CONNECTION 2. Continue as described in points 3. to  8. of the description for the “roof gland”  variant. 9. Now open up the break-out in the end  face of the cover for the cable outlet  (see illustrations on the right). Caution, risk of injury! 10. Now connect the cables from the  turntable on the cables from the  interior of the vehicle, within the casing  (see illustration on the right). 13                                                                                       
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        INSTALLATION AND CONNECTION 11. Insert the cable in the seal and push  it into the cable clips in the casing  (see illustration on the right). 12. Use the plugs attached to seal the  cable attachment points that are now  not required (see illustration on the  right).  Do not cut away any plugs that are  not required, you will need them  if you ever wish to remove the  turntable system. 13. Now place the cover on the casing  lower half and screw the two halves  together using the four screws pre-
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        TECHNICAL DATA (in mm) 90 max. 31 211 Optional  optionaler Cable inlet  Kabeleingang cable outlet  Kabelausgang up to 3 cables up to 3 cables bis zu 3 Kabel bis zu 3 Kabel 2,5 (3x) 38 RAL 9002 (grey white) RAL 9002 (Grauweiß) Interfaces: Schnittstellen:  - Roof hole:   Ø 38 - Dachbohrung: 38  - Cable duct:  W=31, H=17 - Leitungsführungskanal: B  =31, H  =17 max max max max  - Cables: 2x RF  Ø 5; 1xDC   Ø 6.5 - 7  - Kabel: 2x HF 5;  1x DC 6,5 - 7   - Core-drilled hole in the substrate: 3x        
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        FOR YOUR NOTES Internet: http://www.kathrein.de KATHREIN-Werke KG • Anton-Kathrein-Straße 1 - 3  P.O. Box 100 444 • 83004 Rosenheim GERMANY 936.3442/-/0908/ZWT - Technical data subject to change.