Inhaltszusammenfassung zur Seite Nr. 1 
                    
                         
 
 
 
 
 
 
 
 
 
DCP_link 
Multi-Protocol Router 
Advanced Configuration Guide 
 
 
 
 
 
 
 
 
 
 
 
PT1054605-00, Rev A 
December 1995 
                                                                                                                                                                                                                                                                                                                                                                       
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                          Information contained in this document is believed to be accurate and reliable. However,  Emulex Corporation assumes no responsibility for its use nor for any infringements of patents  or other rights of third parties which may result from its use. Emulex Corporation reserves the  right to change product specifications at any time without notice.  The following trademarks of Emulex Corporation are used in this document:  Emulex, DCP-286i-SBC, DCP-386i, DCP 486e, DCP_link, DCPx86i/e  All other 
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        Table of Contents  Preface   Product Support.................................................................................... i   Audience .................................................................................... i   User Guide Conventions...................................................................... ii   Related Documentation...................................................................... iii  Chapter 1 Introduction   Emulex DCP_link..................................
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        Table of Contents ii    Chapter 3 Installation and Cabling   Installing the Emulex Adapter ..........................................................3-3   Cabling Connections.........................................................................3-4   Factory Default Settings....................................................................3-4    DCP286i-SBC Adapter Cables .................................................3-4    DCP386i/DCP486e Daughterboard Cabling ...........................
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        Table of Contents iii    Chapter 4 Software Installation   Software Installation Procedure........................................................ 4-2    Installing to Novell NetWare version 3.12............................... 4-2    Installing to Novell NetWare version 4.1................................. 4-4   Uninstall Procedures.........................................................................4-6    Uninstall using NetWare version 3.12...................................... 4-6    Unin
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        Table of Contents iv    Chapter 7 X.25 Configuration   Introduction .................................................................................7-2    Virtual Circuit Service ..............................................................7-3    Logical Channel Numbers ........................................................7-4    Diagramming Your X.25 Network ...........................................7-5    Planning Your X.25 Network ...................................................7-5   
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        Table of Contents v    Appendix A  Diagnostic Programs   Diagnostic Platform.........................................................................A-2    Diagnostic Operating Requirements........................................ A-2    README.DOC.......................................................................A-2    Distribution Diskette...............................................................A-3    Diagnostic Platform Instructions............................................. A-3   
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        Preface      Thank you for purchasing the DCP_link Multi-Protocol Router. You have  joined the Emulex family of users, who have found that buying our products  guarantees available performance and bandwidth while preserving resources.  We value a strong relationship with our customers and seek to continually  serve your needs in the years to come.  Product Support  Emulex products are supported by a broad range of educational and technical  support services. They are available to help you  maxim
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        ii   Preface  User Guide Conventions  Sections of text that are marked for emphasis are formatted with the  following key words: Note, Important, or Caution.   For example:  CAUTION:  Provides the user with directions to prevent a  mistake from occurring.  When a command is illustrated in the user’s guide, the variable choices  allowed to be changed will appear in a contrasting typeface. All command  lines will begin with a triangular shaped symbol.  An example of a command line is:  > LOAD INET
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                         Preface  iii  Related Documentation  This section is designed to assist the reader in finding third party reference  manuals for the support of NetWare WAN protocols and general networking  architectures and principles.  NetWare Guides (Included with DCP_link)  Novell NetWare MultiProtocol Router 3.0 Installation and Basic  Configuration Guide  Novell NetWare MultiProtocol Router 3.0 Advanced Configuration and  Reference Guide  Protocol Guides  X.25 Explained: Protocols for Packet Switching Net
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        Introduction  Chapter 1    EMULEX DCP_LINK.............................................................................................1-2  HARDWARE REQUIREMENTS...........................................................................1-3  SOFTWARE REQUIREMENTS ............................................................................1-3                                                                                                                                                              
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        1-2   Chapter 1  Emulex DCP_link  Emulex DCP_link is a multi-protocol router including WAN connectivity  software and one of the DCPx86i/e family of communications adapters.  DCP_link is designed to work in conjunction with the Novell NetWare  Branch Link and Enterprise Router, formerly known as the Novell  MultiProtocol Router (MPR 3.0). This unique adapter and software  combination provides remote connectivity across numerous interfaces,  protocols, network types and hardware platforms.  Throu
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        Introduction  1-3  Hardware Requirements  In order to successfully install the Emulex DCP_link software, you must be  running NetWare on a Novell approved hardware platform, or you must first  install the Runtime version of Novell NetWare that is shipped with  DCP_link. If you are running on a Novell approved hardware platform, you  will need the following minimum configuration.  • An Intel (or equivalent) 80386 (minimum) based host server with  ISA/EISA slot(s) available for WAN adapter(s).  • 
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        1-4   Chapter 1  CAUTION: The system must not load any of the following  modules:  - extended memory managers, such as HIMEM,         QEMM, or EMM386.  - disk compression utilities, such as Disk Doubler.  - any terminate-and-stay-resident (TSR) programs.  Verify that the Novell environment meets the following criteria:  • NetWare O/S version 3.12 or version 4.1 (Runtime version included with  DCP_link).  • Novell MultiProtocol Router (Branch Link or Enterprise version) MPR  3.0, (included with D
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        Hardware  Configuration  Chapter 2  FACTORY DEFAULT SETTINGS ......................................................................2-2  BASE I/O ADDRESS .........................................................................................2-3  HOST INTERRUPT LEVEL (IRQ SETTING)........................................................2-5  DCP286I-SBC ADAPTER CONFIGURATION ..................................................2-6  JUMPER SETTINGS .....................................................
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        2-2   Chapter 2  DCP_link  features an 80x86 microprocessor based “intelligent” WAN  adapter to provide powerful co-processing capabilities. The adapter utilizes  1Mb of on-board shared memory to transfer commands and data to the  NetWare server.  DMA channels are included to support full-duplex  operation.  This chapter describes the factory default configuration of the  DCP286i/386i/486e and tells how to configure the board for WAN  applications.    Factory Default Settings  This factory defau
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        Hardware Configuration   2-3  NOTE: The Base I/O address and IRQ settings are the  same for all adapters. Data Clock Direction, DTE,  is correct for all connections except V.35.  Other switch or jumper settings unique to an individual adapter type (i.e.,  DCP286i-SBC, DCP386i, or DCP486e) are detailed in a separate section of  this chapter specific to each adapter.  Base I/O Address  The Base I/O address is selected via switch SW1, which may be labeled CR  ADDR (Control Register Address) on some
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        2-4   Chapter 2  SW1 - Base I/O Address Settings    Figure 2-1  SW1                                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        Hardware Configuration   2-5  Host Interrupt Level (IRQ Setting)  The jumper block used to set the IRQ is unique to each adapter  type.   DCP286i - J13  DCP386i - J6  DCP486e - J11  Refer to the specific adapter section for  the location of this jumper.  The available IRQ jumper settings are:   / IRQ 2    Figure 2-2 Host Interrupt Level Jumper Plug Settings  Use one jumper to select the appropriate interrupt level. As an example, to  configure the adapter for interrupt level 5, set the jumper as
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        2-6   Chapter 2  DCPx86i/e Adapter Configuration  The remainder of Chapter 2 is divided into three sections according to  adapter type (DCP286i-SBC, DCP386i, or DCP486e). Please refer to the  section for the adapter you are installing.     DCP286i-SBC Adapter Configuration  The following diagram of the DCP286i-SBC adapter shows the location of  all option setting switches and jumpers:    Figure 2-4 DCP286i-SBC Jumper Block Placement  Jumper Settings  NOTE: Jumper block J13 sets the Host Interrup